EarthSpotterEarthSpotter

Robertsons Ready Mix Santa Fe Springs

12311 Greenstone, Santa Fe Springs, CA 90670

Robertsons Ready Mix has held an industrial stormwater permit for the site since September 1994. Its industry is listed as ready-mixed concrete. The permit requires samples of its runoff, and the last one it filed is from February 2024. Under its stormwater permit it is at Exceedance Response Action Level 2 for pH, suspended solids, and iron, and the site is in a watershed with a state cleanup plan for metals and selenium.

12311 Greenstone, Santa Fe Springs

Industrial stormwater

This site filed no samples of its runoff in the 2025-2026 reporting year, although rain records show 10 storms of a tenth of an inch or more near it.

The permit requires samples in each half of the year, July to December and January to June. The last sample it filed is from February 2024.

Clean WaterIndustrial stormwater

Missing samples

Clean Water Act. Source: California State Water Resources Control Board, data as of November 23, 2026.

Rain and sampling in 2023-24

The facility sampled 1 of the 17 storms of a tenth of an inch or more near the site in 2023-24.

The permit generally requires samples from four storms a year, with few exceptions.

What the samples show

The state compares each year's average with its benchmark. A site with more than one drainage area samples each one separately, so it can file more than four results for a pollutant in a year. Open a pollutant to see every lab result behind the averages.

  • Yearly average, over
  • Yearly average, within
  • Single lab result
  • State benchmark

Tested in 2023-24

Iron

0.45 mg/L1 result

1 mg/L

Exceedance Response Action Level 2

All results for iron

Settles out as rust-colored sludge that smothers creek beds. The state took its iron benchmark from a 2008 EPA benchmark that the EPA has since stopped using.

7 results as a table
SampledDrainage areaResult
Feb 5, 2024Outfall 30.45 mg/L
Mar 21, 2023Outfall 13.5 mg/L
Feb 14, 2019Outfall 11.4 mg/L
Jan 9, 2018Outfall 22.1 mg/L
Jan 9, 2018Outfall 15.9 mg/L
Jan 5, 2016Outfall 24.8 mg/L
Jan 5, 2016Outfall 127 mg/L

Suspended solids

20 mg/L1 result

100 mg/L

Exceedance Response Action Level 2

All results for suspended solids

Mud and fine particles that cloud water, bury habitat, and carry other pollutants.

7 results as a table
SampledDrainage areaResult
Feb 5, 2024Outfall 320 mg/L
Mar 21, 2023Outfall 1211 mg/L
Feb 14, 2019Outfall 135 mg/L
Jan 9, 2018Outfall 2246 mg/L
Jan 9, 2018Outfall 196 mg/L
Jan 5, 2016Outfall 2181 mg/L
Jan 5, 2016Outfall 1523 mg/L

pH

8 to 81 result

6 to 9

Exceedance Response Action Level 2

All results for pH

Water that is too acidic or too alkaline harms aquatic life and makes metals more toxic.

7 results as a table
SampledDrainage areaResult
Feb 5, 2024Outfall 38
Mar 21, 2023Outfall 18.5
Feb 14, 2019Outfall 18.1
Jan 9, 2018Outfall 24
Jan 9, 2018Outfall 14
Jan 5, 2016Outfall 22
Jan 5, 2016Outfall 11.5

Oil and grease

Not detected1 result

15 mg/L

All results for oil and grease

Coats plants and animals and blocks oxygen from entering the water.

6 results as a table
SampledDrainage areaResult
Feb 5, 2024Outfall 3Not detected
Mar 21, 2023Outfall 1Not detected
Feb 14, 2019Outfall 1Not detected
Jan 9, 2018Outfall 2Not detected
Jan 9, 2018Outfall 1Not detected
Jan 5, 2016Outfall 15.7 mg/L

Rain and sampling by year

The permit asks each site to sample two storms between July and December and two between January and June. When a site samples fewer, its results may not represent its true runoff.

  • Day with rain
  • Day sampled
2025-26

0 of 10 storms sampledTold the state: not enough qualifying storms occurred; another reason

2024-25

0 of 6 storms sampledTold the state it did not sample every required storm

2023-24

1 of 17 storms sampledTold the state it did not sample every required storm

2022-23

1 of 16 storms sampledTold the state it did not sample every required storm

2021-22

0 of 10 storms sampledTold the state it did not sample every required storm

2020-21

0 of 7 storms sampledTold the state it did not sample every required storm

Rainfall comes from the daily records of NOAA station Whittier 2.9 WNW (US1CALA0010), 4.6 miles from the site. It is the nearest station with a full record since 2015. A storm here means a tenth of an inch or more of rain after two dry days.

Location and details

Where the runoff goes

The facility reports that rain running off it drains to San Gabriel River.

The site sits in a watershed with a state cleanup plan for metals and selenium.

Storm drains carry this runoff to creeks and the ocean without treatment.

The neighborhood

About 7,320 people live in the neighborhood around this site in Santa Fe Springs. The state scores it above 97% of California neighborhoods for pollution burden and health vulnerability.

Least burdenedMost burdened

Source: CalEnviroScreen 5.0, census tract 6037504200. The score covers the whole neighborhood and does not measure this site's own effect.

Same operator

Robertsons Ready Mix holds 50 other stormwater permits:

Permits and IDs

Industry
Ready-Mixed Concrete
Operator
Robertsons Ready Mix
Covered by
Industrial stormwater permit
Stormwater permit since
September 1994
Site size
2.3 acres
State stormwater ID
4 19I011157

The state stormwater record

Report pollution at this site

Send photos or video of what you have seen, such as smoke, runoff, or uncovered materials. We review every report.