EarthSpotterEarthSpotter

Ricks Machine Shop

11448 Woodside Ave North, Santee, CA 92071

Ricks Machine Shop has held an industrial stormwater permit for the site since September 2018. Its industry is listed as motor vehicle parts and accessories. The permit requires samples of its runoff, and the last one it filed is from December 2018. Under its stormwater permit it is at Exceedance Response Action Level 1 for suspended solids, which means a qualified professional must review its pollution controls.

11448 Woodside Ave North, Santee

Industrial stormwater

This site last filed a sample of its runoff in December 2018.

The permit requires testing. It has filed no results for the last three years, so there is no public record of what its runoff contains.

Clean WaterIndustrial stormwater

Missing samples

Clean Water Act. Source: California State Water Resources Control Board, data as of November 23, 2026.

Rain and sampling in 2025-26

The facility sampled none of the 10 storms of a tenth of an inch or more near the site in 2025-26.

The permit generally requires samples from four storms a year, with few exceptions. No annual report for 2025-26 is on file. That is the report in which a facility tells the state which storms it sampled and why it missed any.

What the samples show

The state compares each year's average with its benchmark. A site with more than one drainage area samples each one separately, so it can file more than four results for a pollutant in a year. Open a pollutant to see every lab result behind the averages.

  • Yearly average, over
  • Yearly average, within
  • Single lab result
  • State benchmark

Not tested in the latest year

Figures are from the last year each was tested.

Suspended solids

110 mg/L3 results, 3 drainage areas

100 mg/L

Exceedance Response Action Level 1

All results for suspended solids

Mud and fine particles that cloud water, bury habitat, and carry other pollutants.

2018-19 results by drainage area

The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.

Drainage areaResultsAverageHighest
DP#1191 mg/L91 mg/L
DP#2168 mg/L68 mg/L
DP#31170 mg/L170 mg/L
3 results as a table
SampledDrainage areaResult
Dec 7, 2018DP#3170 mg/L
Dec 7, 2018DP#268 mg/L
Dec 7, 2018DP#191 mg/L

pH

7 to 73 results, 3 drainage areas

6 to 9

All results for pH

Water that is too acidic or too alkaline harms aquatic life and makes metals more toxic.

2018-19 results by drainage area

The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.

Drainage areaResultsLowestHighest
DP#1177
DP#2177
DP#3177
3 results as a table
SampledDrainage areaResult
Dec 7, 2018DP#37
Dec 7, 2018DP#27
Dec 7, 2018DP#17

Oil and grease

3.1 mg/L3 results, 3 drainage areas

15 mg/L

All results for oil and grease

Coats plants and animals and blocks oxygen from entering the water.

2018-19 results by drainage area

The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.

Drainage areaResultsAverageHighest
DP#113 mg/L3 mg/L
DP#216.3 mg/L6.3 mg/L
DP#310 mg/L0 mg/L
3 results as a table
SampledDrainage areaResult
Dec 7, 2018DP#3Not detected
Dec 7, 2018DP#26.3 mg/L
Dec 7, 2018DP#13 mg/L

Rain and sampling by year

The permit asks each site to sample two storms between July and December and two between January and June. When a site samples fewer, its results may not represent its true runoff.

  • Day with rain
  • Day sampled
2025-26

0 of 10 storms sampledNo annual report on file

2024-25

0 of 11 storms sampledNo annual report on file

2023-24

0 of 19 storms sampledNo annual report on file

2022-23

0 of 20 storms sampledNo annual report on file

2021-22

0 of 13 storms sampledTold the state it sampled every required storm

2020-21

0 of 10 storms sampledNo annual report on file

Rainfall comes from the daily records of NOAA station Lakeside 2 E (USC00044710), 3.3 miles from the site. It is the nearest station with a full record since 2015. A storm here means a tenth of an inch or more of rain after two dry days.

Location and details

Where the runoff goes

The facility reports that rain running off it drains to San Diego River.

Storm drains carry this runoff to creeks and the ocean without treatment.

The neighborhood

About 3,003 people live in the neighborhood around this site in Santee. The state scores it above 20% of California neighborhoods for pollution burden and health vulnerability.

Least burdenedMost burdened

Source: CalEnviroScreen 5.0, census tract 6073016703. The score covers the whole neighborhood and does not measure this site's own effect.

Permits and IDs

Industry
Motor Vehicle Parts and Accessories
Operator
Ricks Machine Shop
Covered by
Industrial stormwater permit
Stormwater permit since
September 2018
Site size
4.43 acres
Paved or roofed
25% of the site
State stormwater ID
9 37I027859

The state stormwater record

Other sites nearby

Report pollution at this site

Send photos or video of what you have seen, such as smoke, runoff, or uncovered materials. We review every report.

Send a report