EarthSpotterEarthSpotter

Chula Vista Energy Center

3497 Main St, Chula Vista, CA 91911

Chula Vista Energy Center has held an industrial stormwater permit for the site since October 2009. Its industry is listed as electric services. The permit requires samples of its runoff, and the last one it filed is from February 2024.

3497 Main St, Chula Vista

Industrial stormwater

This site filed no samples of its runoff in the 2025-2026 reporting year, although rain records show 9 storms of a tenth of an inch or more near it.

The permit requires samples in each half of the year, July to December and January to June. The last sample it filed is from February 2024.

Clean WaterIndustrial stormwater

Missing samples

Clean Water Act. Source: California State Water Resources Control Board, data as of November 23, 2026.

Rain and sampling in 2023-24

The facility sampled 2 of the 16 storms of a tenth of an inch or more near the site in 2023-24.

The permit generally requires samples from four storms a year, with few exceptions.

What the samples show

The state compares each year's average with its benchmark. A site with more than one drainage area samples each one separately, so it can file more than four results for a pollutant in a year. Open a pollutant to see every lab result behind the averages.

  • Yearly average, over
  • Yearly average, within
  • Single lab result
  • State benchmark

Tested in 2023-24

Iron

0.49 mg/L2 results

1 mg/L

All results for iron

Settles out as rust-colored sludge that smothers creek beds. The state took its iron benchmark from a 2008 EPA benchmark that the EPA has since stopped using.

7 results as a table
SampledDrainage areaResult
Feb 7, 2024CVEC SE Corner0.52 mg/L
Jan 22, 2024CVEC SE Corner0.46 mg/L
Mar 1, 2023CVEC SE Corner1.2 mg/L
Jan 16, 2023CVEC SE Corner0.43 mg/L
Dec 14, 2021CVEC SE CornerNot detected
Dec 4, 2019CVEC SE Corner2.3 mg/L
Jan 18, 2017CVEC SE Corner1.8 mg/L

pH

7.3 to 7.82 results

6 to 9

All results for pH

Water that is too acidic or too alkaline harms aquatic life and makes metals more toxic.

10 results as a table
SampledDrainage areaResult
Feb 7, 2024CVEC SE Corner7.3
Jan 22, 2024CVEC SE Corner7.8
Mar 1, 2023CVEC SE Corner7
Jan 16, 2023CVEC SE Corner7.2
Dec 14, 2021CVEC SE Corner7.2
Dec 4, 2019CVEC SE Corner7.4
Jan 18, 2017CVEC SE Corner6.1
Dec 30, 2016CVEC SE Corner8.2
Dec 16, 2016CVEC SE Corner7.2
May 6, 2016CVEC SE Corner7.7

Suspended solids

42 mg/L2 results

100 mg/L

All results for suspended solids

Mud and fine particles that cloud water, bury habitat, and carry other pollutants.

10 results as a table
SampledDrainage areaResult
Feb 7, 2024CVEC SE Corner62 mg/L
Jan 22, 2024CVEC SE Corner22 mg/L
Mar 1, 2023CVEC SE CornerNot detected
Jan 16, 2023CVEC SE Corner8 mg/L
Dec 14, 2021CVEC SE CornerNot detected
Dec 4, 2019CVEC SE Corner23 mg/L
Jan 18, 2017CVEC SE Corner15 mg/L
Dec 30, 2016CVEC SE Corner224 mg/L
Dec 16, 2016CVEC SE Corner1 mg/L
May 6, 2016CVEC SE Corner2 mg/L

Oil and grease

Not detected2 results

15 mg/L

All results for oil and grease

Coats plants and animals and blocks oxygen from entering the water.

10 results as a table
SampledDrainage areaResult
Feb 7, 2024CVEC SE CornerNot detected
Jan 22, 2024CVEC SE CornerNot detected
Mar 1, 2023CVEC SE CornerNot detected
Jan 16, 2023CVEC SE Corner4.3 mg/L
Dec 14, 2021CVEC SE CornerNot detected
Dec 4, 2019CVEC SE CornerNot detected
Jan 18, 2017CVEC SE Corner1.4 mg/L
Dec 30, 2016CVEC SE Corner1.4 mg/L
Dec 16, 2016CVEC SE Corner1.4 mg/L
May 6, 2016CVEC SE CornerNot detected

Tested once or twice and within the benchmark: ammonia.

Also tested, with no state benchmark to compare against: 4 results for electrical conductivity @ 25 deg. C.

Rain and sampling by year

The permit asks each site to sample two storms between July and December and two between January and June. When a site samples fewer, its results may not represent its true runoff.

  • Day with rain
  • Day sampled
2025-26

0 of 9 storms sampledTold the state: not enough qualifying storms occurred; storms fell outside operating hours; the facility was not operating or was understaffed

2024-25

0 of 7 storms sampledTold the state it did not sample every required storm

2023-24

2 of 16 storms sampledTold the state it did not sample every required storm

2022-23

2 of 17 storms sampledTold the state it did not sample every required storm

2021-22

1 of 12 storms sampledTold the state it did not sample every required storm

2020-21

0 of 8 storms sampledTold the state it did not sample every required storm

Rainfall comes from the daily records of NOAA station Chula Vista (USC00041758), 3.7 miles from the site. It is the nearest station with a full record since 2015. A storm here means a tenth of an inch or more of rain after two dry days.

Location and details

Where the runoff goes

The facility reports that rain running off it drains to Otay River.

Storm drains carry this runoff to creeks and the ocean without treatment.

The neighborhood

About 3,901 people live in the neighborhood around this site in Chula Vista. The state scores it above 81% of California neighborhoods for pollution burden and health vulnerability.

Least burdenedMost burdened

Source: CalEnviroScreen 5.0, census tract 6073013308. The score covers the whole neighborhood and does not measure this site's own effect.

Permits and IDs

Industry
Electric Services
Operator
Chula Vista Energy Center
Covered by
Industrial stormwater permit
Stormwater permit since
October 2009
Site size
3.8 acres
State stormwater ID
9 37I022360

The state stormwater record

Report pollution at this site

Send photos or video of what you have seen, such as smoke, runoff, or uncovered materials. We review every report.