EarthSpotterEarthSpotter

CRR Inc San Juan Cap

31641 Ortega Hwy, San Juan Capistrano, CA 92675

CR&R Inc San Juan Cap has held an industrial stormwater permit for the site since July 1998. Its industry is listed as local trucking with storage. The permit requires samples of its runoff, and the last one it filed is from December 2019.

31641 Ortega Hwy, San Juan Capistrano

Industrial stormwater

This site last filed a sample of its runoff in December 2019.

The permit requires testing. It has filed no results for the last three years, so there is no public record of what its runoff contains.

Clean WaterIndustrial stormwater

Missing samples

Clean Water Act. Source: California State Water Resources Control Board, data as of November 23, 2026.

Rain and sampling in 2025-26

The facility sampled none of the 12 storms of a tenth of an inch or more near the site in 2025-26.

The permit generally requires samples from four storms a year, with few exceptions. The facility told the state it missed storms because storms did not produce a discharge.

What the samples show

The state compares each year's average with its benchmark. A site with more than one drainage area samples each one separately, so it can file more than four results for a pollutant in a year. Open a pollutant to see every lab result behind the averages.

  • Yearly average, over
  • Yearly average, within
  • Single lab result
  • State benchmark

Not tested in the latest year

Figures are from the last year each was tested.

Iron

0.73 mg/L6 results, 3 drainage areas

1 mg/L

All results for iron

Settles out as rust-colored sludge that smothers creek beds. The state took its iron benchmark from a 2008 EPA benchmark that the EPA has since stopped using.

2019-20 results by drainage area

The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.

Drainage areaResultsAverageHighest
MP-120.39 mg/L0.63 mg/L
MP-221.2 mg/L1.9 mg/L
MP-320.55 mg/L0.69 mg/L
27 results as a table
SampledDrainage areaResult
Dec 26, 2019MP-30.41 mg/L
Dec 26, 2019MP-20.53 mg/L
Dec 26, 2019MP-10.15 mg/L
Nov 29, 2019MP-30.69 mg/L
Nov 29, 2019MP-21.9 mg/L
Nov 29, 2019MP-10.63 mg/L
Dec 6, 2018MP-30.17 mg/L
Dec 6, 2018MP-20.088 mg/L
Dec 6, 2018MP-11.7 mg/L
Nov 29, 2018MP-30.058 mg/L
Nov 29, 2018MP-20.089 mg/L
Nov 29, 2018MP-10.81 mg/L
Feb 17, 2017MP-30.3 mg/L
Feb 17, 2017MP-21.9 mg/L
Feb 17, 2017MP-13.1 mg/L
Jan 19, 2017MP-31.3 mg/L
Jan 19, 2017MP-20.48 mg/L
Jan 19, 2017MP-10.84 mg/L
Jan 5, 2017MP-30.066 mg/L
Jan 5, 2017MP-20.059 mg/L
Jan 5, 2017MP-10.46 mg/L
Dec 16, 2016MP-31.6 mg/L
Dec 16, 2016MP-21.6 mg/L
Dec 16, 2016MP-11.6 mg/L
Jan 5, 2016MP-30.15 mg/L
Jan 5, 2016MP-20.11 mg/L
Dec 22, 2015MP-13.1 mg/L

pH

6.8 to 6.96 results, 3 drainage areas

6 to 9

All results for pH

Water that is too acidic or too alkaline harms aquatic life and makes metals more toxic.

2019-20 results by drainage area

The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.

Drainage areaResultsLowestHighest
MP-126.86.9
MP-226.86.9
MP-326.86.9
24 results as a table
SampledDrainage areaResult
Dec 26, 2019MP-36.8
Dec 26, 2019MP-26.8
Dec 26, 2019MP-16.8
Nov 29, 2019MP-36.9
Nov 29, 2019MP-26.9
Nov 29, 2019MP-16.9
Dec 6, 2018MP-37
Dec 6, 2018MP-27
Dec 6, 2018MP-17
Nov 29, 2018MP-37
Nov 29, 2018MP-27
Nov 29, 2018MP-17
Feb 17, 2017MP-37.5
Feb 17, 2017MP-27.5
Feb 17, 2017MP-17.5
Jan 19, 2017MP-36.8
Jan 19, 2017MP-26.8
Jan 19, 2017MP-16.8
Jan 5, 2017MP-37.5
Jan 5, 2017MP-27.5
Jan 5, 2017MP-17.5
Dec 16, 2016MP-38.7
Dec 16, 2016MP-28.7
Dec 16, 2016MP-18.7

Suspended solids

10 mg/L6 results, 3 drainage areas

100 mg/L

All results for suspended solids

Mud and fine particles that cloud water, bury habitat, and carry other pollutants.

2019-20 results by drainage area

The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.

Drainage areaResultsAverageHighest
MP-126.7 mg/L7.4 mg/L
MP-2212 mg/L19 mg/L
MP-3212 mg/L17 mg/L
27 results as a table
SampledDrainage areaResult
Dec 26, 2019MP-37.3 mg/L
Dec 26, 2019MP-24.4 mg/L
Dec 26, 2019MP-15.9 mg/L
Nov 29, 2019MP-317 mg/L
Nov 29, 2019MP-219 mg/L
Nov 29, 2019MP-17.4 mg/L
Dec 6, 2018MP-35.6 mg/L
Dec 6, 2018MP-29.6 mg/L
Dec 6, 2018MP-149 mg/L
Nov 29, 2018MP-32.7 mg/L
Nov 29, 2018MP-23.7 mg/L
Nov 29, 2018MP-155 mg/L
Feb 17, 2017MP-335 mg/L
Feb 17, 2017MP-245 mg/L
Feb 17, 2017MP-1131 mg/L
Jan 19, 2017MP-358 mg/L
Jan 19, 2017MP-216 mg/L
Jan 19, 2017MP-162 mg/L
Jan 5, 2017MP-32.3 mg/L
Jan 5, 2017MP-21.2 mg/L
Jan 5, 2017MP-127 mg/L
Dec 16, 2016MP-342 mg/L
Dec 16, 2016MP-247 mg/L
Dec 16, 2016MP-138 mg/L
Jan 5, 2016MP-36.6 mg/L
Jan 5, 2016MP-28.8 mg/L
Dec 22, 2015MP-1187 mg/L

Oil and grease

1 mg/L6 results, 3 drainage areas

15 mg/L

All results for oil and grease

Coats plants and animals and blocks oxygen from entering the water.

2019-20 results by drainage area

The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.

Drainage areaResultsAverageHighest
MP-122 mg/L2.1 mg/L
MP-220 mg/L0 mg/L
MP-321.1 mg/L2.2 mg/L
27 results as a table
SampledDrainage areaResult
Dec 26, 2019MP-3Not detected
Dec 26, 2019MP-2Not detected
Dec 26, 2019MP-11.9 mg/L
Nov 29, 2019MP-32.2 mg/L
Nov 29, 2019MP-2Not detected
Nov 29, 2019MP-12.1 mg/L
Dec 6, 2018MP-3Not detected
Dec 6, 2018MP-2Not detected
Dec 6, 2018MP-1Not detected
Nov 29, 2018MP-3Not detected
Nov 29, 2018MP-2Not detected
Nov 29, 2018MP-1Not detected
Feb 17, 2017MP-31.8 mg/L
Feb 17, 2017MP-21.8 mg/L
Feb 17, 2017MP-12.3 mg/L
Jan 19, 2017MP-35.6 mg/L
Jan 19, 2017MP-22 mg/L
Jan 19, 2017MP-12.6 mg/L
Jan 5, 2017MP-3Not detected
Jan 5, 2017MP-2Not detected
Jan 5, 2017MP-11.2 mg/L
Dec 16, 2016MP-3Not detected
Dec 16, 2016MP-2Not detected
Dec 16, 2016MP-1Not detected
Jan 5, 2016MP-3Not detected
Jan 5, 2016MP-2Not detected
Dec 22, 2015MP-1Not detected

Also tested, with no state benchmark to compare against: 12 results for electrical conductivity @ 25 deg. C.

Rain and sampling by year

The permit asks each site to sample two storms between July and December and two between January and June. When a site samples fewer, its results may not represent its true runoff.

  • Day with rain
  • Day sampled
2025-26

0 of 12 storms sampledTold the state: storms did not produce a discharge

2024-25

0 of 10 storms sampledTold the state it did not sample every required storm

2023-24

0 of 17 storms sampledTold the state it did not sample every required storm

2022-23

0 of 17 storms sampledTold the state it did not sample every required storm

2021-22

0 of 12 storms sampledTold the state it did not sample every required storm

2020-21

0 of 9 storms sampledTold the state it did not sample every required storm

Rainfall comes from the daily records of NOAA station Mission Viejo 3.5 SSE(K6wta) (US1CAOR0026), 4.7 miles from the site. It is the nearest station with a full record since 2015. A storm here means a tenth of an inch or more of rain after two dry days.

Location and details

Where the runoff goes

The facility reports that rain running off it drains to San Juan Creek Region 9 (not Region 3).

Storm drains carry this runoff to creeks and the ocean without treatment.

The neighborhood

About 2,712 people live in the neighborhood around this site in San Juan Capistrano. The state scores it above 3% of California neighborhoods for pollution burden and health vulnerability.

Least burdenedMost burdened

Source: CalEnviroScreen 5.0, census tract 6059032064. The score covers the whole neighborhood and does not measure this site's own effect.

Same operator

CR&R Inc San Juan Cap holds 1 other stormwater permit:

Permits and IDs

Industry
Local Trucking with Storage
Operator
CR&R Inc San Juan Cap
Covered by
Industrial stormwater permit
Stormwater permit since
July 1998
Site size
11.17 acres
Paved or roofed
70.86% of the site
State stormwater ID
9 30I014441

The state stormwater record

Report pollution at this site

Send photos or video of what you have seen, such as smoke, runoff, or uncovered materials. We review every report.