EarthSpotterEarthSpotter

Orangewood Container Repair

7592 Orangewood Ave, Stanton, CA 90680

CR&R Inc Orangewood has held an industrial stormwater permit for the site since November 2014. Its industry is listed as local trucking without storage. The permit requires samples of its runoff, and the last one it filed is from March 2017.

7592 Orangewood Ave, Stanton

Industrial stormwater

This site last filed a sample of its runoff in March 2017.

The permit requires testing. It has filed no results for the last three years, so there is no public record of what its runoff contains.

Clean WaterIndustrial stormwater

Missing samples

Clean Water Act. Source: California State Water Resources Control Board, data as of November 23, 2026.

Rain and sampling in 2025-26

The facility sampled none of the 8 storms of a tenth of an inch or more near the site in 2025-26.

The permit generally requires samples from four storms a year, with few exceptions. The facility told the state it missed storms because storms did not produce a discharge.

What the samples show

The state compares each year's average with its benchmark. A site with more than one drainage area samples each one separately, so it can file more than four results for a pollutant in a year. Open a pollutant to see every lab result behind the averages.

  • Yearly average, over
  • Yearly average, within
  • Single lab result
  • State benchmark

Not tested in the latest year

Figures are from the last year each was tested.

pH

6.5 to 74 results

6 to 9

All results for pH

Water that is too acidic or too alkaline harms aquatic life and makes metals more toxic.

5 results as a table
SampledDrainage areaResult
Mar 21, 2017MP-17
Feb 17, 2017MP-17
Jan 24, 2017MP-16.5
Jan 9, 2017MP-16.7
Jan 5, 2016MP-13.2

Suspended solids

26 mg/L4 results

100 mg/L

All results for suspended solids

Mud and fine particles that cloud water, bury habitat, and carry other pollutants.

5 results as a table
SampledDrainage areaResult
Mar 21, 2017MP-117 mg/L
Feb 17, 2017MP-171 mg/L
Jan 24, 2017MP-13.7 mg/L
Jan 9, 2017MP-114 mg/L
Jan 5, 2016MP-1Not detected

Oil and grease

1.8 mg/L4 results

15 mg/L

All results for oil and grease

Coats plants and animals and blocks oxygen from entering the water.

5 results as a table
SampledDrainage areaResult
Mar 21, 2017MP-11.4 mg/L
Feb 17, 2017MP-13.9 mg/L
Jan 24, 2017MP-1Not detected
Jan 9, 2017MP-11.8 mg/L
Jan 5, 2016MP-11.8 mg/L

Zinc

0.14 mg/L4 results

0.26 mg/L

All results for zinc

Toxic to fish and the small animals they eat, even at low concentrations.

5 results as a table
SampledDrainage areaResult
Mar 21, 2017MP-10.055 mg/L
Feb 17, 2017MP-10.28 mg/L
Jan 24, 2017MP-10.052 mg/L
Jan 9, 2017MP-10.18 mg/L
Jan 5, 2016MP-10.059 mg/L

Copper

0.019 mg/L4 results

0.0332 mg/L

All results for copper

Toxic to fish at very low concentrations and damages their sense of smell.

5 results as a table
SampledDrainage areaResult
Mar 21, 2017MP-10.05 mg/L
Feb 17, 2017MP-10.013 mg/L
Jan 24, 2017MP-10.003 mg/L
Jan 9, 2017MP-10.0083 mg/L
Jan 5, 2016MP-10.0084 mg/L

Lead

0.0048 mg/L4 results

0.262 mg/L

All results for lead

A nerve poison for people and wildlife that builds up in sediment.

5 results as a table
SampledDrainage areaResult
Mar 21, 2017MP-10.0018 mg/L
Feb 17, 2017MP-10.015 mg/L
Jan 24, 2017MP-10.00081 mg/L
Jan 9, 2017MP-10.0019 mg/L
Jan 5, 2016MP-10.007 mg/L

Iron

0.85 mg/L4 results

1 mg/L

All results for iron

Settles out as rust-colored sludge that smothers creek beds. The state took its iron benchmark from a 2008 EPA benchmark that the EPA has since stopped using.

5 results as a table
SampledDrainage areaResult
Mar 21, 2017MP-10.72 mg/L
Feb 17, 2017MP-11.9 mg/L
Jan 24, 2017MP-10.13 mg/L
Jan 9, 2017MP-10.63 mg/L
Jan 5, 2016MP-10.83 mg/L

Aluminum

0.62 mg/L4 results

0.75 mg/L

All results for aluminum

Toxic to fish and aquatic insects. It builds up on gills.

5 results as a table
SampledDrainage areaResult
Mar 21, 2017MP-10.46 mg/L
Feb 17, 2017MP-11.4 mg/L
Jan 24, 2017MP-10.1 mg/L
Jan 9, 2017MP-10.51 mg/L
Jan 5, 2016MP-10.57 mg/L

Chemical oxygen demand

16 mg/L4 results

120 mg/L

All results for chemical oxygen demand

A measure of oxygen-consuming waste. High readings leave less oxygen for aquatic life.

5 results as a table
SampledDrainage areaResult
Mar 21, 2017MP-1Not detected
Feb 17, 2017MP-1Not detected
Jan 24, 2017MP-1Not detected
Jan 9, 2017MP-164 mg/L
Jan 5, 2016MP-131 mg/L

Also tested, with no state benchmark to compare against: 4 results for electrical conductivity @ 25 deg. C.

Rain and sampling by year

The permit asks each site to sample two storms between July and December and two between January and June. When a site samples fewer, its results may not represent its true runoff.

  • Day with rain
  • Day sampled
2025-26

0 of 8 storms sampledTold the state: storms did not produce a discharge

2024-25

0 of 6 storms sampledTold the state it did not sample every required storm

2023-24

0 of 15 storms sampledTold the state it did not sample every required storm

2022-23

0 of 18 storms sampledTold the state it did not sample every required storm

2021-22

0 of 10 storms sampledTold the state it did not sample every required storm

2020-21

0 of 7 storms sampledTold the state it did not sample every required storm

Rainfall comes from the daily records of NOAA station Fullerton Municipal Airport (USW00003166), 5.3 miles from the site. It is the nearest station with a full record since 2015. A storm here means a tenth of an inch or more of rain after two dry days.

Location and details

Where the runoff goes

The facility reports that rain running off it drains to Bolsa Chica Channel.

Storm drains carry this runoff to creeks and the ocean without treatment.

The neighborhood

About 2,063 people live in the neighborhood around this site in Garden Grove. The state scores it above 88% of California neighborhoods for pollution burden and health vulnerability.

Least burdenedMost burdened

Source: CalEnviroScreen 5.0, census tract 6059088101. The score covers the whole neighborhood and does not measure this site's own effect.

Same operator

CR&R Inc Orangewood holds 1 other stormwater permit:

Permits and IDs

Industry
Local Trucking Without Storage
Operator
CR&R Inc Orangewood
Covered by
Industrial stormwater permit
Stormwater permit since
November 2014
Site size
38000 square feet
Paved or roofed
86.8% of the site
State stormwater ID
8 30I025137

The state stormwater record

Report pollution at this site

Send photos or video of what you have seen, such as smoke, runoff, or uncovered materials. We review every report.

Send a report