EarthSpotterEarthSpotter

Altium Packaging

1217 E Saint Gertrude Pl, Santa Ana, CA 92707

Consolidated Container Co LLC has held an industrial stormwater permit for the site since July 2002. Its industry is listed as plastics bottles. The permit requires samples of its runoff, and the last one it filed is from February 2025. The site is in a watershed with a state cleanup plan for toxic pollutants.

1217 E Saint Gertrude Pl, Santa Ana

Industrial stormwater

This site filed no samples of its runoff in the 2025-2026 reporting year, although rain records show 10 storms of a tenth of an inch or more near it.

The permit requires samples in each half of the year, July to December and January to June. The last sample it filed is from February 2025.

Clean WaterIndustrial stormwater

Missing samples

Clean Water Act. Source: California State Water Resources Control Board, data as of November 23, 2026.

Rain and sampling in 2024-25

The facility sampled 1 of the 6 storms of a tenth of an inch or more near the site in 2024-25.

The permit generally requires samples from four storms a year, with few exceptions.

What the samples show

The state compares each year's average with its benchmark. A site with more than one drainage area samples each one separately, so it can file more than four results for a pollutant in a year. Open a pollutant to see every lab result behind the averages.

  • Yearly average, over
  • Yearly average, within
  • Single lab result
  • State benchmark

Tested in 2024-25

Suspended solids

85 mg/L1 result

100 mg/L

All results for suspended solids

Mud and fine particles that cloud water, bury habitat, and carry other pollutants.

17 results as a table
SampledDrainage areaResult
Feb 7, 2025Standard gate and St. Gertrude gate85 mg/L
Mar 2, 2024Standard gate and St. Gertrude gate14 mg/L
Jan 20, 2024Standard gate and St. Gertrude gate8.2 mg/L
Mar 21, 2023Standard gate and St. Gertrude gate15 mg/L
Jan 14, 2023Standard gate and St. Gertrude gate5.3 mg/L
Jan 29, 2021Mon17.8 mg/L
Dec 4, 2019Standard gate and St. Gertrude gate20 mg/L
May 16, 2019Standard gate and St. Gertrude gate14 mg/L
Jan 11, 2019Mon127 mg/L
Dec 5, 2018Mon116 mg/L
Nov 29, 2018Mon12.9 mg/L
Jan 9, 2018Mon16.8 mg/L
Jan 19, 2017Mon18.4 mg/L
Jan 9, 2017Mon114 mg/L
Dec 16, 2016Mon126 mg/L
Dec 22, 2015Mon18.2 mg/L
Sep 15, 2015Mon1230 mg/L

pH

7 to 71 result

6 to 9

All results for pH

Water that is too acidic or too alkaline harms aquatic life and makes metals more toxic.

17 results as a table
SampledDrainage areaResult
Feb 7, 2025Standard gate and St. Gertrude gate7
Mar 2, 2024Standard gate and St. Gertrude gate7
Jan 20, 2024Standard gate and St. Gertrude gate7
Mar 21, 2023Standard gate and St. Gertrude gate7
Jan 14, 2023Standard gate and St. Gertrude gate7
Jan 29, 2021Mon17
Dec 4, 2019Standard gate and St. Gertrude gate7
May 16, 2019Standard gate and St. Gertrude gate7
Jan 11, 2019Mon17
Dec 5, 2018Mon17
Nov 29, 2018Mon17
Jan 9, 2018Mon17
Jan 19, 2017Mon17
Jan 9, 2017Mon17
Dec 16, 2016Mon17
Dec 22, 2015Mon17
Sep 15, 2015Mon17

Oil and grease

6.7 mg/L1 result

15 mg/L

All results for oil and grease

Coats plants and animals and blocks oxygen from entering the water.

17 results as a table
SampledDrainage areaResult
Feb 7, 2025Standard gate and St. Gertrude gate6.7 mg/L
Mar 2, 2024Standard gate and St. Gertrude gate7.5 mg/L
Jan 20, 2024Standard gate and St. Gertrude gate2.1 mg/L
Mar 21, 2023Standard gate and St. Gertrude gate1.8 mg/L
Jan 14, 2023Standard gate and St. Gertrude gateNot detected
Jan 29, 2021Mon1Not detected
Dec 4, 2019Standard gate and St. Gertrude gateNot detected
May 16, 2019Standard gate and St. Gertrude gateNot detected
Jan 11, 2019Mon13.5 mg/L
Dec 5, 2018Mon112 mg/L
Nov 29, 2018Mon12.9 mg/L
Jan 9, 2018Mon1Not detected
Jan 19, 2017Mon1Not detected
Jan 9, 2017Mon1Not detected
Dec 16, 2016Mon1Not detected
Dec 22, 2015Mon1Not detected
Sep 15, 2015Mon1Not detected

Rain and sampling by year

The permit asks each site to sample two storms between July and December and two between January and June. When a site samples fewer, its results may not represent its true runoff.

  • Day with rain
  • Day sampled
2025-26

0 of 10 storms sampledTold the state: not enough qualifying storms occurred

2024-25

1 of 6 storms sampledTold the state it did not sample every required storm

2023-24

2 of 15 storms sampledTold the state it sampled every required storm

2022-23

2 of 15 storms sampledTold the state it sampled every required storm

2021-22

0 of 8 storms sampledTold the state it did not sample every required storm

2020-21

1 of 7 storms sampledTold the state it did not sample every required storm

Rainfall comes from the daily records of NOAA station Santa Ana Fire Station (USC00047888), 1.8 miles from the site. It is the nearest station with a full record since 2015. A storm here means a tenth of an inch or more of rain after two dry days.

Location and details

Where the runoff goes

The facility reports that rain running off it drains to San Diego Creek.

The site sits in a watershed with a state cleanup plan for toxic pollutants.

Storm drains carry this runoff to creeks and the ocean without treatment.

The neighborhood

About 4,987 people live in the neighborhood around this site in Santa Ana. The state scores it above 94% of California neighborhoods for pollution burden and health vulnerability.

Least burdenedMost burdened

Source: CalEnviroScreen 5.0, census tract 6059074403. The score covers the whole neighborhood and does not measure this site's own effect.

Same operator

Consolidated Container Co LLC holds 5 other stormwater permits:

Permits and IDs

Industry
Plastics Bottles
Operator
Consolidated Container Co LLC
Covered by
Industrial stormwater permit
Stormwater permit since
July 2002
Site size
2 acres
Paved or roofed
20% of the site
State stormwater ID
8 30I017393

The state stormwater record

Report pollution at this site

Send photos or video of what you have seen, such as smoke, runoff, or uncovered materials. We review every report.

Send a report