EarthSpotterEarthSpotter

Dunham Metal Processing

936 N Parker St, Orange, CA 92867

Dunham Metal Processing Inc has held an industrial stormwater permit for the site since July 2001. Its industry is listed as electroplating, plating, polishing, anodizing, and coloring. The permit requires samples of its runoff, and the last one it filed is from January 2019.

936 N Parker St, Orange

Industrial stormwater

This site last filed a sample of its runoff in January 2019.

The permit requires testing. It has filed no results for the last three years, so there is no public record of what its runoff contains.

Clean WaterIndustrial stormwater

Missing samples

Clean Water Act. Source: California State Water Resources Control Board, data as of November 23, 2026.

Rain and sampling in 2025-26

The facility sampled none of the 10 storms of a tenth of an inch or more near the site in 2025-26.

The permit generally requires samples from four storms a year, with few exceptions. The facility told the state it missed storms because not enough qualifying storms occurred and storms fell outside operating hours.

What the samples show

The state compares each year's average with its benchmark. A site with more than one drainage area samples each one separately, so it can file more than four results for a pollutant in a year. Open a pollutant to see every lab result behind the averages.

  • Yearly average, over
  • Yearly average, within
  • Single lab result
  • State benchmark

Not tested in the latest year

Figures are from the last year each was tested.

pH

7.3 to 7.31 result

6 to 9

All results for pH

Water that is too acidic or too alkaline harms aquatic life and makes metals more toxic.

3 results as a table
SampledDrainage areaResult
Jan 31, 2019SW-1 Front of Facility7.3
Jan 8, 2018SW-1 Front of Facility7.2
Feb 17, 2017SW-1 Front of Facility7

Suspended solids

22 mg/L1 result

100 mg/L

All results for suspended solids

Mud and fine particles that cloud water, bury habitat, and carry other pollutants.

3 results as a table
SampledDrainage areaResult
Jan 31, 2019SW-1 Front of Facility22 mg/L
Jan 8, 2018SW-1 Front of Facility19 mg/L
Feb 17, 2017SW-1 Front of Facility4 mg/L

Oil and grease

Not detected1 result

15 mg/L

All results for oil and grease

Coats plants and animals and blocks oxygen from entering the water.

3 results as a table
SampledDrainage areaResult
Jan 31, 2019SW-1 Front of FacilityNot detected
Jan 8, 2018SW-1 Front of Facility3.8 mg/L
Feb 17, 2017SW-1 Front of FacilityNot detected

Zinc

0.08 mg/L1 result

0.26 mg/L

All results for zinc

Toxic to fish and the small animals they eat, even at low concentrations.

3 results as a table
SampledDrainage areaResult
Jan 31, 2019SW-1 Front of Facility0.08 mg/L
Jan 8, 2018SW-1 Front of Facility0.11 mg/L
Feb 17, 2017SW-1 Front of Facility0.016 mg/L

Lead

Not detected1 result

0.262 mg/L

All results for lead

A nerve poison for people and wildlife that builds up in sediment.

3 results as a table
SampledDrainage areaResult
Jan 31, 2019SW-1 Front of FacilityNot detected
Jan 8, 2018SW-1 Front of FacilityNot detected
Feb 17, 2017SW-1 Front of FacilityNot detected

Nitrate and nitrite

0.1 mg/L1 result

0.68 mg/L

All results for nitrate and nitrite

Feeds algae blooms that strip oxygen from creeks and lagoons.

3 results as a table
SampledDrainage areaResult
Jan 31, 2019SW-1 Front of Facility0.1 mg/L
Jan 8, 2018SW-1 Front of FacilityNot detected
Feb 17, 2017SW-1 Front of Facility0.13 mg/L

Nickel

0.025 mg/L1 result

1.02 mg/L

All results for nickel

3 results as a table
SampledDrainage areaResult
Jan 31, 2019SW-1 Front of Facility0.025 mg/L
Jan 8, 2018SW-1 Front of Facility0.018 mg/L
Feb 17, 2017SW-1 Front of Facility0.0053 mg/L

Tested once or twice and within the benchmark: copper, iron, aluminum, cadmium, silver.

Also tested, with no state benchmark to compare against: 3 results for chromium.

Rain and sampling by year

The permit asks each site to sample two storms between July and December and two between January and June. When a site samples fewer, its results may not represent its true runoff.

  • Day with rain
  • Day sampled
2025-26

0 of 10 storms sampledTold the state: not enough qualifying storms occurred; storms fell outside operating hours

2024-25

0 of 6 storms sampledTold the state it did not sample every required storm

2023-24

0 of 15 storms sampledTold the state it did not sample every required storm

2022-23

0 of 15 storms sampledTold the state it did not sample every required storm

2021-22

0 of 8 storms sampledTold the state it did not sample every required storm

2020-21

0 of 7 storms sampledTold the state it did not sample every required storm

Rainfall comes from the daily records of NOAA station Santa Ana Fire Station (USC00047888), 4.2 miles from the site. It is the nearest station with a full record since 2015. A storm here means a tenth of an inch or more of rain after two dry days.

Location and details

Where the runoff goes

The facility reports that rain running off it drains to Santa Ana River.

Storm drains carry this runoff to creeks and the ocean without treatment.

The neighborhood

About 4,267 people live in the neighborhood around this site in Orange. The state scores it above 88% of California neighborhoods for pollution burden and health vulnerability.

Least burdenedMost burdened

Source: CalEnviroScreen 5.0, census tract 6059076204. The score covers the whole neighborhood and does not measure this site's own effect.

Permits and IDs

Industry
Electroplating, Plating, Polishing, Anodizing, and Coloring
Operator
Dunham Metal Processing Inc
Covered by
Industrial stormwater permit
Stormwater permit since
July 2001
Site size
9000 square feet
State stormwater ID
8 30I016654

The state stormwater record

Report pollution at this site

Send photos or video of what you have seen, such as smoke, runoff, or uncovered materials. We review every report.

Send a report