EarthSpotterEarthSpotter

CalEnergy Oper Co Desert Vall

3301 West Highway 86 Desert V, Brawley, CA 92227

CalEnergy Operating Co has held an industrial stormwater permit for the site since April 1992. Its industry is listed as refuse systems. The permit requires samples of its runoff, and the last one it filed is from January 2019. Under its stormwater permit it is at Exceedance Response Action Level 2 for iron, which means it must file an action plan with the state.

3301 West Highway 86 Desert V, Brawley

Industrial stormwater

This site last filed a sample of its runoff in January 2019.

The permit requires testing. It has filed no results for the last three years, so there is no public record of what its runoff contains.

Clean WaterIndustrial stormwater

Missing samples

Clean Water Act. Source: California State Water Resources Control Board, data as of November 23, 2026.

Rain and sampling in 2025-26

The facility sampled none of the 7 storms of a tenth of an inch or more near the site in 2025-26.

The permit generally requires samples from four storms a year, with few exceptions. The facility told the state it missed storms because the facility was not operating or was understaffed and conditions were unsafe. It also gave another reason.

What the samples show

The state compares each year's average with its benchmark. A site with more than one drainage area samples each one separately, so it can file more than four results for a pollutant in a year. Open a pollutant to see every lab result behind the averages.

  • Yearly average, over
  • Yearly average, within
  • Single lab result
  • State benchmark

Not tested in the latest year

Figures are from the last year each was tested.

Iron

2 mg/L1 result

1 mg/L

Exceedance Response Action Level 2

All results for iron

Settles out as rust-colored sludge that smothers creek beds. The state took its iron benchmark from a 2008 EPA benchmark that the EPA has since stopped using.

4 results as a table
SampledDrainage areaResult
Jan 15, 2019ASL for DP5 and DP62 mg/L
Aug 4, 2017DVC NORTH SW IMPACTED0.02 mg/L
Dec 22, 2016DVC NORTH SW IMPACTED7.1 mg/L
Jan 6, 2016DVC NORTH SW IMPACTED30 mg/L

pH

6.28 to 6.281 result

6 to 9

All results for pH

Water that is too acidic or too alkaline harms aquatic life and makes metals more toxic.

4 results as a table
SampledDrainage areaResult
Jan 15, 2019ASL for DP5 and DP66.3
Aug 4, 2017DVC NORTH SW IMPACTED7.8
Dec 22, 2016DVC NORTH SW IMPACTED7.2
Jan 6, 2016DVC NORTH SW IMPACTED7.5

Suspended solids

17 mg/L1 result

100 mg/L

All results for suspended solids

Mud and fine particles that cloud water, bury habitat, and carry other pollutants.

4 results as a table
SampledDrainage areaResult
Jan 15, 2019ASL for DP5 and DP617 mg/L
Aug 4, 2017DVC NORTH SW IMPACTED12 mg/L
Dec 22, 2016DVC NORTH SW IMPACTED23 mg/L
Jan 6, 2016DVC NORTH SW IMPACTED100 mg/L

Oil and grease

Not detected1 result

15 mg/L

All results for oil and grease

Coats plants and animals and blocks oxygen from entering the water.

4 results as a table
SampledDrainage areaResult
Jan 15, 2019ASL for DP5 and DP6Not detected
Aug 4, 2017DVC NORTH SW IMPACTED0 mg/L
Dec 22, 2016DVC NORTH SW IMPACTED3.8 mg/L
Jan 6, 2016DVC NORTH SW IMPACTEDNot detected

Rain and sampling by year

The permit asks each site to sample two storms between July and December and two between January and June. When a site samples fewer, its results may not represent its true runoff.

  • Day with rain
  • Day sampled
2025-26

0 of 7 storms sampledTold the state: the facility was not operating or was understaffed; conditions were unsafe; another reason

2024-25

0 of 3 storms sampledTold the state it did not sample every required storm

2023-24

0 of 9 storms sampledTold the state it did not sample every required storm

2022-23

0 of 9 storms sampledTold the state it did not sample every required storm

2021-22

0 of 4 storms sampledTold the state it did not sample every required storm

2020-21

0 of 2 storms sampledTold the state it did not sample every required storm

Rainfall comes from the daily records of NOAA station Ocotillo Wells 2 W (USC00046386), 21 miles from the site. It is the nearest station with a full record since 2015. A storm here means a tenth of an inch or more of rain after two dry days.

Location and details

Where the runoff goes

The facility reports that rain running off it drains to Ephemeral washes surrounding facility.

Storm drains carry this runoff to creeks and the ocean without treatment.

The neighborhood

About 2,286 people live in the neighborhood around this site in Westmorland. The state scores it above 91% of California neighborhoods for pollution burden and health vulnerability.

Least burdenedMost burdened

Source: CalEnviroScreen 5.0, census tract 6025010200. The score covers the whole neighborhood and does not measure this site's own effect.

Same operator

CalEnergy Operating Co holds 2 other stormwater permits:

Permits and IDs

Industry
Refuse Systems
Operator
CalEnergy Operating Co
Covered by
Industrial stormwater permit
Stormwater permit since
April 1992
Site size
160 acres
State stormwater ID
7 13I005191

The state stormwater record

Report pollution at this site

Send photos or video of what you have seen, such as smoke, runoff, or uncovered materials. We review every report.

Send a report