EarthSpotterEarthSpotter

The Sherwin Williams Company

12401 Industrial Boulevard, Victorville, CA 92392

The Sherwin Williams Manufacturing Company has held an industrial stormwater permit for the site since March 2018. Its industry is listed as paints, varnishes, lacquers, enamels, and allied products. The permit requires samples of its runoff, and the last one it filed is from October 2025. Under its stormwater permit it is at Exceedance Response Action Level 2 for zinc, which means it must file an action plan with the state.

12401 Industrial Boulevard, Victorville

Industrial stormwater

This site filed no samples of its runoff in the 2025-2026 reporting year, although rain records show 9 storms of a tenth of an inch or more near it.

The permit requires samples in each half of the year, July to December and January to June. The last sample it filed is from October 2025.

Clean WaterIndustrial stormwater

Missing samples

Clean Water Act. Source: California State Water Resources Control Board, data as of November 23, 2026.

Rain and sampling in 2025-26

The facility sampled 1 of the 9 storms of a tenth of an inch or more near the site in 2025-26.

The permit generally requires samples from four storms a year, with few exceptions. The facility told the state it missed storms because storms did not produce a discharge and storms fell outside operating hours. It also gave another reason.

What the samples show

The state compares each year's average with its benchmark. A site with more than one drainage area samples each one separately, so it can file more than four results for a pollutant in a year. Open a pollutant to see every lab result behind the averages.

  • Yearly average, over
  • Yearly average, within
  • Single lab result
  • State benchmark

Tested in 2025-26

Zinc

0.14 mg/L1 result

0.26 mg/L

Exceedance Response Action Level 2

All results for zinc

Toxic to fish and the small animals they eat, even at low concentrations.

10 results as a table
SampledDrainage areaResult
Oct 14, 2025Outfall 10.14 mg/L
Mar 13, 2025Outfall 10.13 mg/L
Feb 6, 2024Outfall 10.5 mg/L
Jan 22, 2024Outfall 10.42 mg/L
Feb 15, 2022Outfall 10.31 mg/L
Dec 14, 2021Outfall 10.27 mg/L
Jan 25, 2021Outfall 10.16 mg/L
Mar 10, 2020Outfall 10.19 mg/L
Dec 4, 2019Outfall 10.22 mg/L
Dec 6, 2018Outfall 10.25 mg/L

pH

7 to 71 result

6 to 9

All results for pH

Water that is too acidic or too alkaline harms aquatic life and makes metals more toxic.

10 results as a table
SampledDrainage areaResult
Oct 14, 2025Outfall 17
Mar 13, 2025Outfall 17
Feb 6, 2024Outfall 17
Jan 22, 2024Outfall 17
Feb 15, 2022Outfall 17.4
Dec 14, 2021Outfall 17.7
Jan 25, 2021Outfall 18
Mar 10, 2020Outfall 17.9
Dec 4, 2019Outfall 18.1
Dec 6, 2018Outfall 17.5

Suspended solids

24 mg/L1 result

100 mg/L

All results for suspended solids

Mud and fine particles that cloud water, bury habitat, and carry other pollutants.

10 results as a table
SampledDrainage areaResult
Oct 14, 2025Outfall 124 mg/L
Mar 13, 2025Outfall 139 mg/L
Feb 6, 2024Outfall 163 mg/L
Jan 22, 2024Outfall 182 mg/L
Feb 15, 2022Outfall 129 mg/L
Dec 14, 2021Outfall 140 mg/L
Jan 25, 2021Outfall 152 mg/L
Mar 10, 2020Outfall 135 mg/L
Dec 4, 2019Outfall 162 mg/L
Dec 6, 2018Outfall 160 mg/L

Oil and grease

Not detected1 result

15 mg/L

All results for oil and grease

Coats plants and animals and blocks oxygen from entering the water.

10 results as a table
SampledDrainage areaResult
Oct 14, 2025Outfall 1Not detected
Mar 13, 2025Outfall 1Not detected
Feb 6, 2024Outfall 1Not detected
Jan 22, 2024Outfall 1Not detected
Feb 15, 2022Outfall 1Not detected
Dec 14, 2021Outfall 1Not detected
Jan 25, 2021Outfall 1Not detected
Mar 10, 2020Outfall 1Not detected
Dec 4, 2019Outfall 1Not detected
Dec 6, 2018Outfall 1Not detected

Rain and sampling by year

The permit asks each site to sample two storms between July and December and two between January and June. When a site samples fewer, its results may not represent its true runoff.

  • Day with rain
  • Day sampled
2025-26

1 of 9 storms sampledTold the state: storms did not produce a discharge; storms fell outside operating hours; another reason

2024-25

1 of 7 storms sampledTold the state it did not sample every required storm

2023-24

2 of 11 storms sampledTold the state it did not sample every required storm

2022-23

0 of 14 storms sampledTold the state it did not sample every required storm

2021-22

2 of 7 storms sampledTold the state it sampled every required storm

2020-21

1 of 3 storms sampledTold the state it did not sample every required storm

Rainfall comes from the daily records of NOAA station Victorville (USC00049325), 3.5 miles from the site. It is the nearest station with a full record since 2015. A storm here means a tenth of an inch or more of rain after two dry days.

Location and details

Where the runoff goes

The facility reports that rain running off it drains to Mojave River.

Storm drains carry this runoff to creeks and the ocean without treatment.

The neighborhood

About 6,543 people live in the neighborhood around this site in Victorville. The state scores it above 81% of California neighborhoods for pollution burden and health vulnerability.

Least burdenedMost burdened

Source: CalEnviroScreen 5.0, census tract 6071010037. The score covers the whole neighborhood and does not measure this site's own effect.

Same operator

The Sherwin Williams Manufacturing Company holds 2 other stormwater permits:

Permits and IDs

Industry
Paints, Varnishes, Lacquers, Enamels, and Allied Products
Operator
The Sherwin Williams Manufacturing Company
Covered by
Industrial stormwater permit
Stormwater permit since
March 2018
Site size
16 acres
Paved or roofed
70% of the site
State stormwater ID
6B36I027653

The state stormwater record

Other sites nearby

Report pollution at this site

Send photos or video of what you have seen, such as smoke, runoff, or uncovered materials. We review every report.

Send a report