EarthSpotterEarthSpotter

Southern CA Logistics Airport

18374 Phantom West, Victorville, CA 92394

Southern CA Logistics Airport Authority has held an industrial stormwater permit for the site since August 2007. Its industry is listed as airports, flying fields, and airport terminal services. The permit requires samples of its runoff, and the last one it filed is from February 2019. Under its stormwater permit it is at Exceedance Response Action Level 1 for suspended solids, which means a qualified professional must review its pollution controls.

18374 Phantom West, Victorville

Industrial stormwater

This site last filed a sample of its runoff in February 2019.

The permit requires testing. It has filed no results for the last three years, so there is no public record of what its runoff contains.

Clean WaterIndustrial stormwater

Missing samples

Clean Water Act. Source: California State Water Resources Control Board, data as of November 23, 2026.

Rain and sampling in 2025-26

The facility sampled none of the 9 storms of a tenth of an inch or more near the site in 2025-26.

The permit generally requires samples from four storms a year, with few exceptions.

What the samples show

The state compares each year's average with its benchmark. A site with more than one drainage area samples each one separately, so it can file more than four results for a pollutant in a year. Open a pollutant to see every lab result behind the averages.

  • Yearly average, over
  • Yearly average, within
  • Single lab result
  • State benchmark

Not tested in the latest year

Figures are from the last year each was tested.

Suspended solids

65 mg/L2 results, 2 drainage areas

100 mg/L

Exceedance Response Action Level 1

All results for suspended solids

Mud and fine particles that cloud water, bury habitat, and carry other pollutants.

2018-19 results by drainage area

The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.

Drainage areaResultsAverageHighest
#1 Echo164 mg/L64 mg/L
#6 Main165 mg/L65 mg/L
6 results as a table
SampledDrainage areaResult
Feb 14, 2019#6 Main65 mg/L
Feb 14, 2019#1 Echo64 mg/L
Dec 22, 2016#6 Main140 mg/L
Dec 22, 2016#1 Echo22 mg/L
Jan 6, 2016#6 Main450 mg/L
Jan 6, 2016#1 Echo200 mg/L

pH

6.8 to 6.82 results, 2 drainage areas

6 to 9

All results for pH

Water that is too acidic or too alkaline harms aquatic life and makes metals more toxic.

2018-19 results by drainage area

The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.

Drainage areaResultsLowestHighest
#1 Echo16.86.8
#6 Main16.86.8
6 results as a table
SampledDrainage areaResult
Feb 14, 2019#6 Main6.8
Feb 14, 2019#1 Echo6.8
Dec 22, 2016#6 Main6.7
Dec 22, 2016#1 Echo6.8
Jan 6, 2016#6 Main7.2
Jan 6, 2016#1 Echo7.2

Oil and grease

2.2 mg/L2 results, 2 drainage areas

15 mg/L

All results for oil and grease

Coats plants and animals and blocks oxygen from entering the water.

2018-19 results by drainage area

The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.

Drainage areaResultsAverageHighest
#1 Echo12.3 mg/L2.3 mg/L
#6 Main12.1 mg/L2.1 mg/L
6 results as a table
SampledDrainage areaResult
Feb 14, 2019#6 Main2.1 mg/L
Feb 14, 2019#1 Echo2.3 mg/L
Dec 22, 2016#6 MainNot detected
Dec 22, 2016#1 Echo2.1 mg/L
Jan 6, 2016#6 Main2.4 mg/L
Jan 6, 2016#1 Echo3.2 mg/L

Rain and sampling by year

The permit asks each site to sample two storms between July and December and two between January and June. When a site samples fewer, its results may not represent its true runoff.

  • Day with rain
  • Day sampled
2025-26

0 of 9 storms sampledTold the state it sampled every required storm

2024-25

0 of 7 storms sampledTold the state it sampled every required storm

2023-24

0 of 11 storms sampledTold the state it sampled every required storm

2022-23

0 of 14 storms sampledTold the state it did not sample every required storm

2021-22

0 of 7 storms sampledTold the state it did not sample every required storm

2020-21

0 of 3 storms sampledTold the state it did not sample every required storm

Rainfall comes from the daily records of NOAA station Victorville (USC00049325), 6.1 miles from the site. It is the nearest station with a full record since 2015. A storm here means a tenth of an inch or more of rain after two dry days.

Location and details

Where the runoff goes

The facility reports that rain running off it drains to Mojave River.

Storm drains carry this runoff to creeks and the ocean without treatment.

Permits and IDs

Industry
Airports, Flying Fields, and Airport Terminal Services
Operator
Southern CA Logistics Airport Authority
Covered by
Industrial stormwater permit
Stormwater permit since
August 2007
Site size
2300 acres
State stormwater ID
6B36I021075

The state stormwater record

Report pollution at this site

Send photos or video of what you have seen, such as smoke, runoff, or uncovered materials. We review every report.

Send a report