EarthSpotterEarthSpotter

Center Unified School District

8408 Watt Ave, Antelope, CA 95843

Center Unified School District has held an industrial stormwater permit for the site since March 2003. Its industry is listed as school buses. The permit requires samples of its runoff, and the last one it filed is from November 2025.

8408 Watt Ave, Antelope

Industrial stormwater

This site filed no samples of its runoff in the 2025-2026 reporting year, although rain records show 15 storms of a tenth of an inch or more near it.

The permit requires samples in each half of the year, July to December and January to June. The last sample it filed is from November 2025.

Clean WaterIndustrial stormwater

Missing samples

Clean Water Act. Source: California State Water Resources Control Board, data as of November 23, 2026.

Rain and sampling in 2025-26

The facility sampled 1 of the 15 storms of a tenth of an inch or more near the site in 2025-26.

The permit generally requires samples from four storms a year, with few exceptions.

What the samples show

The state compares each year's average with its benchmark. A site with more than one drainage area samples each one separately, so it can file more than four results for a pollutant in a year. Open a pollutant to see every lab result behind the averages.

  • Yearly average, over
  • Yearly average, within
  • Single lab result
  • State benchmark

Tested in 2025-26

Suspended solids

56 mg/L1 result

100 mg/L

All results for suspended solids

Mud and fine particles that cloud water, bury habitat, and carry other pollutants.

18 results as a table
SampledDrainage areaResult
Nov 5, 2025DI Bus Garage56 mg/L
Feb 4, 2025DI Bus Garage53 mg/L
Dec 12, 2024DI Bus Garage35 mg/L
Feb 7, 2024DI Bus Garage110 mg/L
Dec 6, 2023DI Bus Garage51 mg/L
Dec 1, 2022DI Bus Garage93 mg/L
Mar 15, 2022DI Bus Garage69 mg/L
Oct 21, 2021DI Bus Garage94 mg/L
Jan 27, 2021DI Bus Garage54 mg/L
Nov 18, 2020DI Bus Garage52 mg/L
Sep 16, 2019DI Bus Garage130 mg/L
May 16, 2019DI Bus Garage30 mg/L
Feb 25, 2019DI Bus Garage120 mg/L
Jan 8, 2018DI Bus Garage30 mg/L
Feb 2, 2017D.I. Bus Barn41 mg/L
Dec 15, 2016D.I. Bus Barn68 mg/L
Apr 22, 2016D.I. Bus Barn80 mg/L
Nov 2, 2015DI Bus Garage34 mg/L

pH

7 to 71 result

6 to 9

All results for pH

Water that is too acidic or too alkaline harms aquatic life and makes metals more toxic.

17 results as a table
SampledDrainage areaResult
Nov 5, 2025DI Bus Garage7
Feb 4, 2025DI Bus Garage7
Dec 12, 2024DI Bus Garage7
Feb 7, 2024DI Bus Garage7
Dec 6, 2023DI Bus Garage7
Dec 1, 2022DI Bus Garage7
Mar 15, 2022DI Bus Garage7
Oct 21, 2021DI Bus Garage7
Jan 27, 2021DI Bus Garage7
Nov 18, 2020DI Bus Garage7
Sep 16, 2019DI Bus Garage7
Feb 25, 2019DI Bus Garage6
Jan 8, 2018DI Bus Garage7
Feb 2, 2017D.I. Bus Barn7
Dec 15, 2016D.I. Bus Barn7
Apr 22, 2016D.I. Bus Barn7
Nov 2, 2015DI Bus Garage7

Oil and grease

1.3 mg/L1 result

15 mg/L

All results for oil and grease

Coats plants and animals and blocks oxygen from entering the water.

17 results as a table
SampledDrainage areaResult
Nov 5, 2025DI Bus Garage1.3 mg/L
Feb 4, 2025DI Bus Garage3.4 mg/L
Dec 12, 2024DI Bus Garage26 mg/L
Feb 7, 2024DI Bus Garage2.2 mg/L
Dec 6, 2023DI Bus Garage18 mg/L
Dec 1, 2022DI Bus Garage5.3 mg/L
Mar 15, 2022DI Bus Garage5.3 mg/L
Oct 21, 2021DI Bus Garage2.1 mg/L
Jan 27, 2021DI Bus Garage2.9 mg/L
Nov 18, 2020DI Bus Garage1.2 mg/L
Sep 16, 2019DI Bus Garage1.3 mg/L
Feb 25, 2019DI Bus Garage5 mg/L
Jan 8, 2018DI Bus Garage2.5 mg/L
Feb 2, 2017D.I. Bus Barn3.6 mg/L
Dec 15, 2016D.I. Bus Barn7.1 mg/L
Apr 22, 2016D.I. Bus Barn6.1 mg/L
Nov 2, 2015DI Bus GarageNot detected

Also tested, with no state benchmark to compare against: 12 results for gasoline and 5 for diesel oil.

Rain and sampling by year

The permit asks each site to sample two storms between July and December and two between January and June. When a site samples fewer, its results may not represent its true runoff.

  • Day with rain
  • Day sampled
2025-26

1 of 15 storms sampledTold the state it sampled every required storm

2024-25

2 of 14 storms sampledTold the state it sampled every required storm

2023-24

2 of 22 storms sampledTold the state it sampled every required storm

2022-23

1 of 15 storms sampledTold the state it sampled every required storm

2021-22

2 of 12 storms sampledTold the state it sampled every required storm

2020-21

2 of 14 storms sampledTold the state it sampled every required storm

Rainfall comes from the daily records of NOAA station Sacramento 8.0 NE (US1CASA0002), 6.2 miles from the site. It is the nearest station with a full record since 2015. A storm here means a tenth of an inch or more of rain after two dry days.

Location and details

Where the runoff goes

The facility reports that rain running off it drains to Dry Creek.

Storm drains carry this runoff to creeks and the ocean without treatment.

The neighborhood

About 3,850 people live in the neighborhood around this site in Antelope. The state scores it above 27% of California neighborhoods for pollution burden and health vulnerability.

Least burdenedMost burdened

Source: CalEnviroScreen 5.0, census tract 6067007417. The score covers the whole neighborhood and does not measure this site's own effect.

Permits and IDs

Industry
School Buses
Operator
Center Unified School District
Covered by
Industrial stormwater permit
Stormwater permit since
March 2003
Site size
3.5 acres
Paved or roofed
90% of the site
State stormwater ID
5S34I017907

The state stormwater record

Report pollution at this site

Send photos or video of what you have seen, such as smoke, runoff, or uncovered materials. We review every report.

Send a report