EarthSpotterEarthSpotter

Curtiss Wright Surface Technologies

2588 A Industry Wy, Lynwood, CA 90262

Curtiss Wright Surface Technologies has held an industrial stormwater permit for the site since October 2025. Its industry is listed as metal heat treating. Its runoff was over the state benchmark for aluminum, suspended solids, and iron in 2025-26. Under its stormwater permit it is at Exceedance Response Action Level 1 for suspended solids, iron, and aluminum, and the site is in a watershed with a state cleanup plan for metals and nutrients.

2588 A Industry Wy, Lynwood

Industrial stormwater

During the 2025-2026 rainy season, the site exceeded benchmarks set by the state for aluminum, suspended solids, and iron.

Its yearly average for aluminum was 5 times the benchmark.

Clean WaterIndustrial stormwater

Over a state benchmark

Clean Water Act. Source: California State Water Resources Control Board, data as of November 23, 2026.

Rain and sampling in 2025-26

The facility sampled 2 of the 9 storms of a tenth of an inch or more near the site in 2025-26.

The permit generally requires samples from four storms a year, with few exceptions. The facility told the state it missed storms because not enough qualifying storms occurred, storms did not produce a discharge, and storms fell outside operating hours.

What the samples show

The state compares each year's average with its benchmark. A site with more than one drainage area samples each one separately, so it can file more than four results for a pollutant in a year. Open a pollutant to see every lab result behind the averages.

  • Yearly average, over
  • Yearly average, within
  • Single lab result
  • State benchmark

Over the benchmark in 2025-26

Aluminum

3.8 mg/L4 results, 2 drainage areas

0.75 mg/L

Exceedance Response Action Level 1

All results for aluminum

Toxic to fish and aquatic insects. It builds up on gills.

2025-26 results by drainage area

The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.

Drainage areaResultsAverageHighest
S125.5 mg/L10 mg/L
S222.1 mg/L3.3 mg/L
4 results as a table
SampledDrainage areaResult
Feb 16, 2026S20.84 mg/L
Feb 16, 2026S10.77 mg/L
Nov 14, 2025S23.3 mg/L
Nov 14, 2025S110 mg/L

Suspended solids

140 mg/L4 results, 2 drainage areas

100 mg/L

Exceedance Response Action Level 1

All results for suspended solids

Mud and fine particles that cloud water, bury habitat, and carry other pollutants.

2025-26 results by drainage area

The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.

Drainage areaResultsAverageHighest
S1288 mg/L138 mg/L
S22192 mg/L329 mg/L
4 results as a table
SampledDrainage areaResult
Feb 16, 2026S255 mg/L
Feb 16, 2026S139 mg/L
Nov 14, 2025S2329 mg/L
Nov 14, 2025S1138 mg/L

Iron

13 mg/L4 results, 2 drainage areas

1 mg/L

Exceedance Response Action Level 1

All results for iron

Settles out as rust-colored sludge that smothers creek beds. The state took its iron benchmark from a 2008 EPA benchmark that the EPA has since stopped using.

2025-26 results by drainage area

The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.

Drainage areaResultsAverageHighest
S1222 mg/L43 mg/L
S223.5 mg/L5.4 mg/L
4 results as a table
SampledDrainage areaResult
Feb 16, 2026S21.6 mg/L
Feb 16, 2026S11.6 mg/L
Nov 14, 2025S25.4 mg/L
Nov 14, 2025S143 mg/L

Within the benchmark

pH

7 to 74 results, 2 drainage areas

6 to 9

All results for pH

Water that is too acidic or too alkaline harms aquatic life and makes metals more toxic.

2025-26 results by drainage area

The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.

Drainage areaResultsLowestHighest
S1277
S2277
4 results as a table
SampledDrainage areaResult
Feb 16, 2026S27
Feb 16, 2026S17
Nov 14, 2025S27
Nov 14, 2025S17

Oil and grease

2.9 mg/L4 results, 2 drainage areas

15 mg/L

All results for oil and grease

Coats plants and animals and blocks oxygen from entering the water.

2025-26 results by drainage area

The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.

Drainage areaResultsAverageHighest
S124.9 mg/L9.8 mg/L
S220.85 mg/L1.7 mg/L
4 results as a table
SampledDrainage areaResult
Feb 16, 2026S2Not detected
Feb 16, 2026S1Not detected
Nov 14, 2025S21.7 mg/L
Nov 14, 2025S19.8 mg/L

Rain and sampling by year

The permit asks each site to sample two storms between July and December and two between January and June. When a site samples fewer, its results may not represent its true runoff.

  • Day with rain
  • Day sampled
2025-26

2 of 9 storms sampledTold the state: not enough qualifying storms occurred; storms did not produce a discharge; storms fell outside operating hours

2024-25

0 of 0 storms sampledNo annual report on file

2023-24

0 of 0 storms sampledNo annual report on file

2022-23

0 of 0 storms sampledNo annual report on file

2021-22

0 of 0 storms sampledNo annual report on file

2020-21

0 of 0 storms sampledNo annual report on file

Rainfall comes from the daily records of NOAA station Hawthorne Municipal Airport (USW00003167), 6 miles from the site. It is the nearest station with a full record since 2015. A storm here means a tenth of an inch or more of rain after two dry days.

Location and details

Where the runoff goes

The facility reports that rain running off it drains to Compton Creek/Los Angeles River.

The site sits in a watershed with a state cleanup plan for metals and nutrients.

Storm drains carry this runoff to creeks and the ocean without treatment.

The neighborhood

About 5,110 people live in the neighborhood around this site in Lynwood. The state scores it above 99% of California neighborhoods for pollution burden and health vulnerability.

Least burdenedMost burdened

Source: CalEnviroScreen 5.0, census tract 6037540501. The score covers the whole neighborhood and does not measure this site's own effect.

Same operator

Curtiss Wright Surface Technologies holds 1 other stormwater permit:

Permits and IDs

Industry
Metal Heat Treating
Operator
Curtiss Wright Surface Technologies
Covered by
Industrial stormwater permit
Stormwater permit since
October 2025
Site size
39200 square feet
Paved or roofed
100% of the site
State stormwater ID
4 19I031290

The state stormwater record

Report pollution at this site

Send photos or video of what you have seen, such as smoke, runoff, or uncovered materials. We review every report.