EarthSpotterEarthSpotter

PSCMB Repairs Inc

12145 Slauson Ave, Santa Fe Springs, CA 90670

PSCMB Repairs Inc has held an industrial stormwater permit for the site since September 2020. Its industry is listed as industrial and commercial machinery and equipment. Its runoff was over a state benchmark in 2 of the 3 years it sampled in the last five, most recently in 2024-25 for copper. Under its stormwater permit it is at Exceedance Response Action Level 1 for copper, and its runoff drains to R4 - Coyote Creek and its tributary/ies, where a state cleanup plan sets stricter limits for copper, lead, and zinc.

12145 Slauson Ave, Santa Fe Springs

Industrial stormwater

During the 2024-2025 rainy season, the site exceeded the benchmark set by the state for copper.

Its yearly average for copper was 1.1 times the benchmark. It has exceeded at least one benchmark in 2 of the last 3 years it sampled.

Clean WaterIndustrial stormwater

Over a state benchmark

Clean Water Act. Source: California State Water Resources Control Board, data as of November 23, 2026.

Rain and sampling in 2024-25

The facility sampled 2 of the 6 storms of a tenth of an inch or more near the site in 2024-25.

The permit generally requires samples from four storms a year, with few exceptions.

What the samples show

The state compares each year's average with its benchmark. A site with more than one drainage area samples each one separately, so it can file more than four results for a pollutant in a year. Open a pollutant to see every lab result behind the averages.

  • Yearly average, over
  • Yearly average, within
  • Single lab result
  • State benchmark

Over the benchmark in 2024-25

Copper

0.036 mg/L2 results

0.0332 mg/L

Exceedance Response Action Level 1

All results for copper

Toxic to fish at very low concentrations and damages their sense of smell.

8 results as a table
SampledDrainage areaResult
Mar 13, 2025DP-10.055 mg/L
Feb 13, 2025DP-10.018 mg/L
Feb 6, 2024DP-10.011 mg/L
Jan 22, 2024DP-10.0017 mg/L
May 4, 2023DP-10.038 mg/L
Mar 29, 2023DP-10.0039 mg/L
Feb 24, 2023DP-10.19 mg/L
Jan 5, 2023DP-10.14 mg/L

Within the benchmark

Zinc

0.07 mg/L2 results

0.26 mg/L

All results for zinc

Toxic to fish and the small animals they eat, even at low concentrations.

8 results as a table
SampledDrainage areaResult
Mar 13, 2025DP-10.038 mg/L
Feb 13, 2025DP-10.1 mg/L
Feb 6, 2024DP-1Not detected
Jan 22, 2024DP-10.034 mg/L
May 4, 2023DP-11.4 mg/L
Mar 29, 2023DP-10.046 mg/L
Feb 24, 2023DP-13.5 mg/L
Jan 5, 2023DP-10.32 mg/L

Iron

0.06 mg/L2 results

1 mg/L

All results for iron

Settles out as rust-colored sludge that smothers creek beds. The state took its iron benchmark from a 2008 EPA benchmark that the EPA has since stopped using.

8 results as a table
SampledDrainage areaResult
Mar 13, 2025DP-10.12 mg/L
Feb 13, 2025DP-1Not detected
Feb 6, 2024DP-10.07 mg/L
Jan 22, 2024DP-1Not detected
May 4, 2023DP-10.44 mg/L
Mar 29, 2023DP-10.07 mg/L
Feb 24, 2023DP-14.1 mg/L
Jan 5, 2023DP-13.8 mg/L

pH

6 to 62 results

6 to 9

All results for pH

Water that is too acidic or too alkaline harms aquatic life and makes metals more toxic.

5 results as a table
SampledDrainage areaResult
Mar 13, 2025DP-16
Feb 13, 2025DP-16
May 4, 2023DP-16
Mar 29, 2023DP-16
Feb 24, 2023DP-16

Suspended solids

2 mg/L2 results

100 mg/L

All results for suspended solids

Mud and fine particles that cloud water, bury habitat, and carry other pollutants.

8 results as a table
SampledDrainage areaResult
Mar 13, 2025DP-13 mg/L
Feb 13, 2025DP-11 mg/L
Feb 6, 2024DP-1Not detected
Jan 22, 2024DP-1Not detected
May 4, 2023DP-114 mg/L
Mar 29, 2023DP-1Not detected
Feb 24, 2023DP-124 mg/L
Jan 5, 2023DP-125 mg/L

Oil and grease

Not detected2 results

15 mg/L

All results for oil and grease

Coats plants and animals and blocks oxygen from entering the water.

8 results as a table
SampledDrainage areaResult
Mar 13, 2025DP-1Not detected
Feb 13, 2025DP-1Not detected
Feb 6, 2024DP-1Not detected
Jan 22, 2024DP-1Not detected
May 4, 2023DP-1Not detected
Mar 29, 2023DP-1Not detected
Feb 24, 2023DP-1Not detected
Jan 5, 2023DP-15.1 mg/L

Lead

Not detected2 results

0.262 mg/L

All results for lead

A nerve poison for people and wildlife that builds up in sediment.

8 results as a table
SampledDrainage areaResult
Mar 13, 2025DP-1Not detected
Feb 13, 2025DP-1Not detected
Feb 6, 2024DP-1Not detected
Jan 22, 2024DP-1Not detected
May 4, 2023DP-10.0071 mg/L
Mar 29, 2023DP-10.0004 mg/L
Feb 24, 2023DP-10.031 mg/L
Jan 5, 2023DP-10.031 mg/L

Stricter limits under the R4 - San Gabriel River Metals and Selenium cleanup plan

This site drains to R4 - Coyote Creek and its tributary/ies, which has a cleanup plan. These apply to single results, not yearly averages. Two or more results over in a year count as an exceedance.

PollutantLimitResults over in 2024-25
Copper0.027 mg/L1 of 2Becomes a legal limit on Jul 1, 2020
Lead0.106 mg/L0 of 2Becomes a legal limit on Jul 1, 2020
Zinc0.158 mg/L0 of 2Becomes a legal limit on Jul 1, 2020

Rain and sampling by year

The permit asks each site to sample two storms between July and December and two between January and June. When a site samples fewer, its results may not represent its true runoff.

  • Day with rain
  • Day sampled
2025-26

0 of 10 storms sampledTold the state: another reason

2024-25

2 of 6 storms sampledTold the state it did not sample every required storm

2023-24

2 of 17 storms sampledTold the state it did not sample every required storm

2022-23

4 of 16 storms sampledTold the state it sampled every required storm

2021-22

0 of 10 storms sampledTold the state it did not sample every required storm

2020-21

0 of 7 storms sampledTold the state it did not sample every required storm

Rainfall comes from the daily records of NOAA station Whittier 2.9 WNW (US1CALA0010), 1.7 miles from the site. It is the nearest station with a full record since 2015. A storm here means a tenth of an inch or more of rain after two dry days.

Location and details

Where the runoff goes

The facility reports that rain running off it drains to Coyote Creek, San Gabriel River Reach 1 and Estuary, and San Pedro Bay Near/Off S.

The site sits in a watershed with a state cleanup plan for metals and selenium.

Storm drains carry this runoff to creeks and the ocean without treatment.

The neighborhood

About 7,159 people live in the neighborhood around this site in Santa Fe Springs. The state scores it above 86% of California neighborhoods for pollution burden and health vulnerability.

Least burdenedMost burdened

Source: CalEnviroScreen 5.0, census tract 6037502700. The score covers the whole neighborhood and does not measure this site's own effect.

Permits and IDs

Industry
Industrial and Commercial Machinery and Equipment, NEC
Operator
PSCMB Repairs Inc
Covered by
Industrial stormwater permit
Stormwater permit since
September 2020
Site size
16000 square feet
State stormwater ID
4 19I028839

The state stormwater record

Report pollution at this site

Send photos or video of what you have seen, such as smoke, runoff, or uncovered materials. We review every report.

Send a report