EarthSpotterEarthSpotter

Diversified Spring Tech Inc

9233 Santa Fe Springs Rd, Santa Fe Springs, CA 90670

Diversified Spring Tech Inc has held an industrial stormwater permit for the site since April 2020. Its industry is listed as wire springs. The permit requires samples of its runoff, and the last one it filed is from February 2026. Its runoff drains to R4 - Coyote Creek and its tributary/ies, where a state cleanup plan sets stricter limits for zinc.

9233 Santa Fe Springs Rd, Santa Fe Springs

Industrial stormwater

This site filed no samples of its runoff in the 2025-2026 reporting year, although rain records show 10 storms of a tenth of an inch or more near it.

The permit requires samples in each half of the year, July to December and January to June. The last sample it filed is from February 2026.

Clean WaterIndustrial stormwater

Missing samples

Clean Water Act. Source: California State Water Resources Control Board, data as of November 23, 2026.

Rain and sampling in 2025-26

The facility sampled 1 of the 10 storms of a tenth of an inch or more near the site in 2025-26.

The permit generally requires samples from four storms a year, with few exceptions. The facility told the state it missed storms because not enough qualifying storms occurred.

What the samples show

The state compares each year's average with its benchmark. A site with more than one drainage area samples each one separately, so it can file more than four results for a pollutant in a year. Open a pollutant to see every lab result behind the averages.

  • Yearly average, over
  • Yearly average, within
  • Single lab result
  • State benchmark

Tested in 2025-26

Iron

0.28 mg/L1 result

1 mg/L

All results for iron

Settles out as rust-colored sludge that smothers creek beds. The state took its iron benchmark from a 2008 EPA benchmark that the EPA has since stopped using.

8 results as a table
SampledDrainage areaResult
Feb 16, 2026Sample Point #10.28 mg/L
Feb 13, 2025Sample Point #10.74 mg/L
Feb 1, 2024Sample Point #10.16 mg/L
May 4, 2023Sample Point #11.4 mg/L
Mar 10, 2023Sample Point #10.38 mg/L
Nov 8, 2022Sample Point #10.59 mg/L
Dec 14, 2021Sample Point #10.49 mg/L
Jan 29, 2021Sample Point #11.3 mg/L

pH

7 to 71 result

6 to 9

All results for pH

Water that is too acidic or too alkaline harms aquatic life and makes metals more toxic.

8 results as a table
SampledDrainage areaResult
Feb 16, 2026Sample Point #17
Feb 13, 2025Sample Point #17
Feb 1, 2024Sample Point #17
May 4, 2023Sample Point #16.2
Mar 10, 2023Sample Point #16.2
Nov 8, 2022Sample Point #16.2
Dec 14, 2021Sample Point #16.2
Jan 29, 2021Sample Point #18.1

Suspended solids

6.6 mg/L1 result

100 mg/L

All results for suspended solids

Mud and fine particles that cloud water, bury habitat, and carry other pollutants.

8 results as a table
SampledDrainage areaResult
Feb 16, 2026Sample Point #16.6 mg/L
Feb 13, 2025Sample Point #18.7 mg/L
Feb 1, 2024Sample Point #11.1 mg/L
May 4, 2023Sample Point #124 mg/L
Mar 10, 2023Sample Point #14 mg/L
Nov 8, 2022Sample Point #111 mg/L
Dec 14, 2021Sample Point #19 mg/L
Jan 29, 2021Sample Point #110 mg/L

Oil and grease

0.9 mg/L1 result

15 mg/L

All results for oil and grease

Coats plants and animals and blocks oxygen from entering the water.

8 results as a table
SampledDrainage areaResult
Feb 16, 2026Sample Point #10.9 mg/L
Feb 13, 2025Sample Point #1Not detected
Feb 1, 2024Sample Point #1Not detected
May 4, 2023Sample Point #1Not detected
Mar 10, 2023Sample Point #1Not detected
Nov 8, 2022Sample Point #1Not detected
Dec 14, 2021Sample Point #1Not detected
Jan 29, 2021Sample Point #1Not detected

Zinc

0.032 mg/L1 result

0.26 mg/L

All results for zinc

Toxic to fish and the small animals they eat, even at low concentrations.

8 results as a table
SampledDrainage areaResult
Feb 16, 2026Sample Point #10.032 mg/L
Feb 13, 2025Sample Point #1Not detected
Feb 1, 2024Sample Point #10.022 mg/L
May 4, 2023Sample Point #10.071 mg/L
Mar 10, 2023Sample Point #10.026 mg/L
Nov 8, 2022Sample Point #10.046 mg/L
Dec 14, 2021Sample Point #10.048 mg/L
Jan 29, 2021Sample Point #10.084 mg/L

Aluminum

0.11 mg/L1 result

0.75 mg/L

All results for aluminum

Toxic to fish and aquatic insects. It builds up on gills.

7 results as a table
SampledDrainage areaResult
Feb 16, 2026Sample Point #10.11 mg/L
Feb 13, 2025Sample Point #10.0071 mg/L
Feb 1, 2024Sample Point #10.021 mg/L
May 4, 2023Sample Point #10.5 mg/L
Mar 10, 2023Sample Point #10.14 mg/L
Nov 8, 2022Sample Point #10.11 mg/L
Jan 29, 2021Sample Point #10.58 mg/L

Nitrate and nitrite

0.11 mg/L1 result

0.68 mg/L

All results for nitrate and nitrite

Feeds algae blooms that strip oxygen from creeks and lagoons.

7 results as a table
SampledDrainage areaResult
Feb 16, 2026Sample Point #10.11 mg/L
Feb 13, 2025Sample Point #10.18 mg/L
Feb 1, 2024Sample Point #10.12 mg/L
May 4, 2023Sample Point #10.2 mg/L
Mar 10, 2023Sample Point #10.15 mg/L
Nov 8, 2022Sample Point #10.33 mg/L
Jan 29, 2021Sample Point #10.5 mg/L

Nickel

Not detected1 result

1.02 mg/L

All results for nickel

4 results as a table
SampledDrainage areaResult
Feb 16, 2026Sample Point #1Not detected
Feb 13, 2025Sample Point #1Not detected
Feb 1, 2024Sample Point #10.00051 mg/L
Dec 14, 2021Sample Point #10.004 mg/L

Stricter limits under the R4 - San Gabriel River Metals and Selenium cleanup plan

This site drains to R4 - Coyote Creek and its tributary/ies, which has a cleanup plan. These apply to single results, not yearly averages. Two or more results over in a year count as an exceedance.

PollutantLimitResults over in 2025-26
Zinc0.158 mg/L0 of 1Becomes a legal limit on Jul 1, 2020

Rain and sampling by year

The permit asks each site to sample two storms between July and December and two between January and June. When a site samples fewer, its results may not represent its true runoff.

  • Day with rain
  • Day sampled
2025-26

1 of 10 storms sampledTold the state: not enough qualifying storms occurred

2024-25

1 of 6 storms sampledTold the state it did not sample every required storm

2023-24

1 of 17 storms sampledTold the state it did not sample every required storm

2022-23

3 of 16 storms sampledTold the state it did not sample every required storm

2021-22

1 of 10 storms sampledTold the state it did not sample every required storm

2020-21

1 of 7 storms sampledTold the state it did not sample every required storm

Rainfall comes from the daily records of NOAA station Whittier 2.9 WNW (US1CALA0010), 2.2 miles from the site. It is the nearest station with a full record since 2015. A storm here means a tenth of an inch or more of rain after two dry days.

Location and details

Where the runoff goes

The facility reports that rain running off it drains to Coyote Creek.

The site sits in a watershed with a state cleanup plan for metals and selenium.

Storm drains carry this runoff to creeks and the ocean without treatment.

The neighborhood

About 7,159 people live in the neighborhood around this site in Santa Fe Springs. The state scores it above 86% of California neighborhoods for pollution burden and health vulnerability.

Least burdenedMost burdened

Source: CalEnviroScreen 5.0, census tract 6037502700. The score covers the whole neighborhood and does not measure this site's own effect.

Permits and IDs

Industry
Wire Springs
Operator
Diversified Spring Tech Inc
Covered by
Industrial stormwater permit
Stormwater permit since
April 2020
Site size
41600 square feet
Paved or roofed
90% of the site
State stormwater ID
4 19I028603

The state stormwater record

Other sites nearby

Report pollution at this site

Send photos or video of what you have seen, such as smoke, runoff, or uncovered materials. We review every report.

Send a report