GSP Metal Finishing Inc has held an industrial stormwater permit for the site since November 2019. Its industry is listed as electroplating, plating, polishing, anodizing, and coloring. The permit requires samples of its runoff, and the last one it filed is from February 2026. The site is in a watershed with a state cleanup plan for toxic and metals.
16520 S Figueroa Street, Gardena
Industrial stormwater
This site filed no samples of its runoff in the 2025-2026 reporting year, although rain records show 9 storms of a tenth of an inch or more near it.
The permit requires samples in each half of the year, July to December and January to June. The last sample it filed is from February 2026.
Clean WaterIndustrial stormwater
Missing samples
Clean Water Act. Source: California State Water Resources Control Board, data as of November 23, 2026.
Rain and sampling in 2025-26
The facility sampled 1 of the 9 storms of a tenth of an inch or more near the site in 2025-26.
The permit generally requires samples from four storms a year, with few exceptions. The facility told the state it missed storms because not enough qualifying storms occurred, storms did not produce a discharge, and storms fell outside operating hours. It also gave another reason.
What the samples show
The state compares each year's average with its benchmark. A site with more than one drainage area samples each one separately, so it can file more than four results for a pollutant in a year. Open a pollutant to see every lab result behind the averages.
Yearly average, over
Yearly average, within
Single lab result
State benchmark
Tested in 2025-26
Pollutant2025-26 averageBenchmarkLast five years
pH
6.05 to 6.051 result
6 to 9
Over in 0 of 4 years tested
All results for pH
Water that is too acidic or too alkaline harms aquatic life and makes metals more toxic.
6 results as a table
Sampled
Drainage area
Result
Feb 16, 2026
Driveway Effluent
6
Feb 13, 2025
Driveway Effluent
7.6
Feb 5, 2024
Driveway Effluent
6.3
Dec 20, 2023
Driveway Effluent
6.5
Jan 10, 2023
Driveway Effluent
7
Mar 3, 2021
Driveway Effluent
6.8
Suspended solids
Not detected1 result
100 mg/L
Over in 0 of 4 years tested
All results for suspended solids
Mud and fine particles that cloud water, bury habitat, and carry other pollutants.
6 results as a table
Sampled
Drainage area
Result
Feb 16, 2026
Driveway Effluent
Not detected
Feb 13, 2025
Driveway Effluent
3 mg/L
Feb 5, 2024
Driveway Effluent
4 mg/L
Dec 20, 2023
Driveway Effluent
5 mg/L
Jan 10, 2023
Driveway Effluent
Not detected
Mar 3, 2021
Driveway Effluent
32 mg/L
Oil and grease
Not detected1 result
15 mg/L
Over in 0 of 4 years tested
All results for oil and grease
Coats plants and animals and blocks oxygen from entering the water.
6 results as a table
Sampled
Drainage area
Result
Feb 16, 2026
Driveway Effluent
Not detected
Feb 13, 2025
Driveway Effluent
Not detected
Feb 5, 2024
Driveway Effluent
Not detected
Dec 20, 2023
Driveway Effluent
Not detected
Jan 10, 2023
Driveway Effluent
Not detected
Mar 3, 2021
Driveway Effluent
Not detected
Zinc
0.089 mg/L1 result
0.26 mg/L
Over in 0 of 4 years tested
All results for zinc
Toxic to fish and the small animals they eat, even at low concentrations.
6 results as a table
Sampled
Drainage area
Result
Feb 16, 2026
Driveway Effluent
0.089 mg/L
Feb 13, 2025
Driveway Effluent
0.058 mg/L
Feb 5, 2024
Driveway Effluent
0.082 mg/L
Dec 20, 2023
Driveway Effluent
0.16 mg/L
Jan 10, 2023
Driveway Effluent
0.035 mg/L
Mar 3, 2021
Driveway Effluent
0.15 mg/L
Copper
0.0056 mg/L1 result
0.0332 mg/L
Over in 0 of 4 years tested
All results for copper
Toxic to fish at very low concentrations and damages their sense of smell.
6 results as a table
Sampled
Drainage area
Result
Feb 16, 2026
Driveway Effluent
0.0056 mg/L
Feb 13, 2025
Driveway Effluent
0.01 mg/L
Feb 5, 2024
Driveway Effluent
0.009 mg/L
Dec 20, 2023
Driveway Effluent
0.02 mg/L
Jan 10, 2023
Driveway Effluent
0.0031 mg/L
Mar 3, 2021
Driveway Effluent
0.015 mg/L
Lead
0.0016 mg/L1 result
0.262 mg/L
Over in 0 of 4 years tested
All results for lead
A nerve poison for people and wildlife that builds up in sediment.
6 results as a table
Sampled
Drainage area
Result
Feb 16, 2026
Driveway Effluent
0.0016 mg/L
Feb 13, 2025
Driveway Effluent
0.0018 mg/L
Feb 5, 2024
Driveway Effluent
0.0004 mg/L
Dec 20, 2023
Driveway Effluent
0.0013 mg/L
Jan 10, 2023
Driveway Effluent
0.0004 mg/L
Mar 3, 2021
Driveway Effluent
0.0048 mg/L
Iron
0.11 mg/L1 result
1 mg/L
Over in 0 of 4 years tested
All results for iron
Settles out as rust-colored sludge that smothers creek beds. The state took its iron benchmark from a 2008 EPA benchmark that the EPA has since stopped using.
6 results as a table
Sampled
Drainage area
Result
Feb 16, 2026
Driveway Effluent
0.11 mg/L
Feb 13, 2025
Driveway Effluent
0.4 mg/L
Feb 5, 2024
Driveway Effluent
Not detected
Dec 20, 2023
Driveway Effluent
0.14 mg/L
Jan 10, 2023
Driveway Effluent
0.03 mg/L
Mar 3, 2021
Driveway Effluent
0.93 mg/L
Aluminum
0.079 mg/L1 result
0.75 mg/L
Over in 0 of 4 years tested
All results for aluminum
Toxic to fish and aquatic insects. It builds up on gills.
6 results as a table
Sampled
Drainage area
Result
Feb 16, 2026
Driveway Effluent
0.079 mg/L
Feb 13, 2025
Driveway Effluent
0.15 mg/L
Feb 5, 2024
Driveway Effluent
0.019 mg/L
Dec 20, 2023
Driveway Effluent
0.084 mg/L
Jan 10, 2023
Driveway Effluent
0.017 mg/L
Mar 3, 2021
Driveway Effluent
0.69 mg/L
Nitrate and nitrite
0.14 mg/L1 result
0.68 mg/L
Over in 0 of 4 years tested
All results for nitrate and nitrite
Feeds algae blooms that strip oxygen from creeks and lagoons.
6 results as a table
Sampled
Drainage area
Result
Feb 16, 2026
Driveway Effluent
0.14 mg/L
Feb 13, 2025
Driveway Effluent
0.19 mg/L
Feb 5, 2024
Driveway Effluent
0.18 mg/L
Dec 20, 2023
Driveway Effluent
0.25 mg/L
Jan 10, 2023
Driveway Effluent
0.13 mg/L
Mar 3, 2021
Driveway Effluent
Not detected
Nickel
0.017 mg/L1 result
1.02 mg/L
Over in 0 of 4 years tested
All results for nickel
6 results as a table
Sampled
Drainage area
Result
Feb 16, 2026
Driveway Effluent
0.017 mg/L
Feb 13, 2025
Driveway Effluent
0.0075 mg/L
Feb 5, 2024
Driveway Effluent
0.0018 mg/L
Dec 20, 2023
Driveway Effluent
0.0022 mg/L
Jan 10, 2023
Driveway Effluent
0.0005 mg/L
Mar 3, 2021
Driveway Effluent
0.0025 mg/L
Also tested, with no state benchmark to compare against: 6 results for chromium.
Rain and sampling by year
The permit asks each site to sample two storms between July and December and two between January and June. When a site samples fewer, its results may not represent its true runoff.
Day with rain
Day sampled
2025-26
1 of 9 storms sampledTold the state: not enough qualifying storms occurred; storms did not produce a discharge; storms fell outside operating hours; another reason
2024-25
1 of 6 storms sampledTold the state it did not sample every required storm
2023-24
2 of 14 storms sampledTold the state it sampled every required storm
2022-23
1 of 17 storms sampledTold the state it did not sample every required storm
2021-22
0 of 6 storms sampledTold the state it did not sample every required storm
2020-21
1 of 6 storms sampledTold the state it sampled every required storm
JulAugSepOctNovDecJanFebMarAprMayJun
Rainfall comes from the daily records of NOAA station Hawthorne Municipal Airport (USW00003167), 4.1 miles from the site. It is the nearest station with a full record since 2015. A storm here means a tenth of an inch or more of rain after two dry days.
Location and details
Where the runoff goes
The facility reports that rain running off it drains to Dominguez Channel (336).
The site sits in a watershed with a state cleanup plan for toxic and metals.
Storm drains carry this runoff to creeks and the ocean without treatment.
The neighborhood
About 4,602 people live in the neighborhood around this site in Gardena. The state scores it above 97% of California neighborhoods for pollution burden and health vulnerability.
Least burdenedMost burdened
Source: CalEnviroScreen 5.0, census tract 6037541003. The score covers the whole neighborhood and does not measure this site's own effect.
Permits and IDs
Industry
Electroplating, Plating, Polishing, Anodizing, and Coloring