Samadi Wardak LLC has held an industrial stormwater permit for the site since May 2019. Its industry is listed as motor vehicle parts, used. The permit requires samples of its runoff, and the last one it filed is from January 2026. Its runoff drains to Dominguez Channel Estuary, where a state cleanup plan sets stricter limits for copper, lead, and zinc.
2223 E Anaheim Street, Wilmington
Industrial stormwater
This site filed no samples of its runoff in the 2025-2026 reporting year, although rain records show 10 storms of a tenth of an inch or more near it.
The permit requires samples in each half of the year, July to December and January to June. The last sample it filed is from January 2026.
Clean WaterIndustrial stormwater
Missing samples
Clean Water Act. Source: California State Water Resources Control Board, data as of November 23, 2026.
Rain and sampling in 2025-26
The facility sampled 1 of the 10 storms of a tenth of an inch or more near the site in 2025-26.
The permit generally requires samples from four storms a year, with few exceptions. The facility told the state it missed storms because not enough qualifying storms occurred.
What the samples show
The state compares each year's average with its benchmark. A site with more than one drainage area samples each one separately, so it can file more than four results for a pollutant in a year. Open a pollutant to see every lab result behind the averages.
Yearly average, over
Yearly average, within
Single lab result
State benchmark
Tested in 2025-26
Pollutant2025-26 averageBenchmarkLast five years
Zinc
0.049 mg/L1 result
0.26 mg/L
Over in 1 of 5 years tested
All results for zinc
Toxic to fish and the small animals they eat, even at low concentrations.
7 results as a table
Sampled
Drainage area
Result
Jan 2, 2026
DP1
0.049 mg/L
Feb 12, 2025
DP1
0.48 mg/L
Feb 5, 2024
DP1
0.05 mg/L
Feb 25, 2023
DP1
0.055 mg/L
Mar 28, 2022
DP1
0.1 mg/L
Oct 25, 2021
DP1
0.15 mg/L
Dec 28, 2020
DP1
0.03 mg/L
Copper
0.0022 mg/L1 result
0.0332 mg/L
Over in 1 of 5 years tested
All results for copper
Toxic to fish at very low concentrations and damages their sense of smell.
7 results as a table
Sampled
Drainage area
Result
Jan 2, 2026
DP1
0.0022 mg/L
Feb 12, 2025
DP1
0.034 mg/L
Feb 5, 2024
DP1
0.0019 mg/L
Feb 25, 2023
DP1
0.0068 mg/L
Mar 28, 2022
DP1
0.0078 mg/L
Oct 25, 2021
DP1
Not detected
Dec 28, 2020
DP1
0.0022 mg/L
Iron
0.11 mg/L1 result
1 mg/L
Over in 1 of 5 years tested
All results for iron
Settles out as rust-colored sludge that smothers creek beds. The state took its iron benchmark from a 2008 EPA benchmark that the EPA has since stopped using.
7 results as a table
Sampled
Drainage area
Result
Jan 2, 2026
DP1
0.11 mg/L
Feb 12, 2025
DP1
3.7 mg/L
Feb 5, 2024
DP1
0.036 mg/L
Feb 25, 2023
DP1
0.23 mg/L
Mar 28, 2022
DP1
0.4 mg/L
Oct 25, 2021
DP1
0.084 mg/L
Dec 28, 2020
DP1
0.06 mg/L
pH
6 to 61 result
6 to 9
Over in 0 of 5 years tested
All results for pH
Water that is too acidic or too alkaline harms aquatic life and makes metals more toxic.
7 results as a table
Sampled
Drainage area
Result
Jan 2, 2026
DP1
6
Feb 12, 2025
DP1
7
Feb 5, 2024
DP1
7
Feb 25, 2023
DP1
8
Mar 28, 2022
DP1
7
Oct 25, 2021
DP1
7
Dec 28, 2020
DP1
6
Suspended solids
3.8 mg/L1 result
100 mg/L
Over in 0 of 5 years tested
All results for suspended solids
Mud and fine particles that cloud water, bury habitat, and carry other pollutants.
7 results as a table
Sampled
Drainage area
Result
Jan 2, 2026
DP1
3.8 mg/L
Feb 12, 2025
DP1
12 mg/L
Feb 5, 2024
DP1
6 mg/L
Feb 25, 2023
DP1
9.7 mg/L
Mar 28, 2022
DP1
19 mg/L
Oct 25, 2021
DP1
5.8 mg/L
Dec 28, 2020
DP1
6.7 mg/L
Oil and grease
Not detected1 result
15 mg/L
Over in 0 of 5 years tested
All results for oil and grease
Coats plants and animals and blocks oxygen from entering the water.
7 results as a table
Sampled
Drainage area
Result
Jan 2, 2026
DP1
Not detected
Feb 12, 2025
DP1
6.7 mg/L
Feb 5, 2024
DP1
2.9 mg/L
Feb 25, 2023
DP1
1.1 mg/L
Mar 28, 2022
DP1
1.6 mg/L
Oct 25, 2021
DP1
1.7 mg/L
Dec 28, 2020
DP1
Not detected
Lead
0.00096 mg/L1 result
0.262 mg/L
Over in 0 of 5 years tested
All results for lead
A nerve poison for people and wildlife that builds up in sediment.
7 results as a table
Sampled
Drainage area
Result
Jan 2, 2026
DP1
0.00096 mg/L
Feb 12, 2025
DP1
0.017 mg/L
Feb 5, 2024
DP1
0.00068 mg/L
Feb 25, 2023
DP1
0.0016 mg/L
Mar 28, 2022
DP1
0.002 mg/L
Oct 25, 2021
DP1
Not detected
Dec 28, 2020
DP1
0.00027 mg/L
Aluminum
0.42 mg/L1 result
0.75 mg/L
Over in 0 of 5 years tested
All results for aluminum
Toxic to fish and aquatic insects. It builds up on gills.
7 results as a table
Sampled
Drainage area
Result
Jan 2, 2026
DP1
0.42 mg/L
Feb 12, 2025
DP1
0.56 mg/L
Feb 5, 2024
DP1
0.025 mg/L
Feb 25, 2023
DP1
0.097 mg/L
Mar 28, 2022
DP1
0.21 mg/L
Oct 25, 2021
DP1
Not detected
Dec 28, 2020
DP1
0.038 mg/L
Chemical oxygen demand
21 mg/L1 result
120 mg/L
Over in 0 of 5 years tested
All results for chemical oxygen demand
A measure of oxygen-consuming waste. High readings leave less oxygen for aquatic life.
7 results as a table
Sampled
Drainage area
Result
Jan 2, 2026
DP1
21 mg/L
Feb 12, 2025
DP1
95 mg/L
Feb 5, 2024
DP1
95 mg/L
Feb 25, 2023
DP1
41 mg/L
Mar 28, 2022
DP1
Not detected
Oct 25, 2021
DP1
20 mg/L
Dec 28, 2020
DP1
Not detected
Stricter limits under the R4 - Los Angeles and Long Beach Harbor Waters cleanup plan
This site drains to Dominguez Channel Estuary, which has a cleanup plan. These apply to single results, not yearly averages. Two or more results over in a year count as an exceedance.
Pollutant
Limit
Results over in 2025-26
Copper
0.0058 mg/L
0 of 1
Lead
0.221 mg/L
0 of 1
Zinc
0.095 mg/L
0 of 1
Rain and sampling by year
The permit asks each site to sample two storms between July and December and two between January and June. When a site samples fewer, its results may not represent its true runoff.
Day with rain
Day sampled
2025-26
1 of 10 storms sampledTold the state: not enough qualifying storms occurred
2024-25
0 of 6 storms sampledTold the state it did not sample every required storm
2023-24
1 of 17 storms sampledTold the state it did not sample every required storm
2022-23
1 of 16 storms sampledTold the state it did not sample every required storm
2021-22
2 of 8 storms sampledTold the state it did not sample every required storm
2020-21
1 of 6 storms sampledTold the state it did not sample every required storm
JulAugSepOctNovDecJanFebMarAprMayJun
Rainfall comes from the daily records of NOAA station Long Beach Daugherty Airport (USW00023129), 5.4 miles from the site. It is the nearest station with a full record since 2015. A storm here means a tenth of an inch or more of rain after two dry days.
Location and details
Where the runoff goes
The facility reports that rain running off it drains to Dominguez Channel Estuary.
The site sits in a watershed with a state cleanup plan for toxic and metals.
Storm drains carry this runoff to creeks and the ocean without treatment.