EarthSpotterEarthSpotter

Green Light Used Auto Parts Inc

10975 Tuxford St, Sun Valley, CA 91352

Green Light Used Auto Parts Inc has held an industrial stormwater permit for the site since November 2008. Its industry is listed as motor vehicle parts, used. The permit requires samples of its runoff, and the last one it filed is from December 2025. Under its stormwater permit it is at Exceedance Response Action Level 1 for zinc, and its runoff drains to Los Angeles River and Los Angeles River Tributaries, where a state cleanup plan sets stricter limits for copper, lead, and zinc.

10975 Tuxford St, Sun Valley

Industrial stormwater

This site filed no samples of its runoff in the 2025-2026 reporting year, although rain records show 10 storms of a tenth of an inch or more near it.

The permit requires samples in each half of the year, July to December and January to June. The last sample it filed is from December 2025.

Clean WaterIndustrial stormwater

Missing samples

Clean Water Act. Source: California State Water Resources Control Board, data as of November 23, 2026.

Rain and sampling in 2025-26

The facility sampled 2 of the 10 storms of a tenth of an inch or more near the site in 2025-26.

The permit generally requires samples from four storms a year, with few exceptions. The facility told the state it missed storms because not enough qualifying storms occurred.

What the samples show

The state compares each year's average with its benchmark. A site with more than one drainage area samples each one separately, so it can file more than four results for a pollutant in a year. Open a pollutant to see every lab result behind the averages.

  • Yearly average, over
  • Yearly average, within
  • Single lab result
  • State benchmark

Tested in 2025-26

Zinc

0.023 mg/L2 results

0.26 mg/L

Exceedance Response Action Level 1

All results for zinc

Toxic to fish and the small animals they eat, even at low concentrations.

9 results as a table
SampledDrainage areaResult
Dec 24, 2025Front Gate0.019 mg/L
Nov 14, 2025Front Gate0.027 mg/L
Apr 3, 2025Front Gate1.3 mg/L
Mar 28, 2022Front Gate0.026 mg/L
Oct 25, 2021Front Gate0.036 mg/L
Mar 12, 2020Front Gate0.4 mg/L
Nov 29, 2019Front Gate0.016 mg/L
Jan 17, 2019Front Gate0.0068 mg/L
Jan 8, 2018Front Gate0.0082 mg/L

Aluminum

0.013 mg/L2 results

0.75 mg/L

All results for aluminum

Toxic to fish and aquatic insects. It builds up on gills.

11 results as a table
SampledDrainage areaResult
Dec 24, 2025Front Gate0.0089 mg/L
Nov 14, 2025Front Gate0.017 mg/L
Apr 3, 2025Front Gate0.027 mg/L
Mar 28, 2022Front Gate0.039 mg/L
Oct 25, 2021Front Gate0.17 mg/L
Mar 12, 2020Front Gate0.12 mg/L
Nov 29, 2019Front Gate0.0069 mg/L
Jan 17, 2019Front Gate0.0057 mg/L
Jan 8, 2018Front Gate0.0056 mg/L
Feb 17, 2017Front Gate0.011 mg/L
Jan 5, 2016Front Gate0.88 mg/L

pH

7 to 72 results

6 to 9

All results for pH

Water that is too acidic or too alkaline harms aquatic life and makes metals more toxic.

11 results as a table
SampledDrainage areaResult
Dec 24, 2025Front Gate7
Nov 14, 2025Front Gate7
Apr 3, 2025Front Gate8
Mar 28, 2022Front Gate6.2
Oct 25, 2021Front Gate6.4
Mar 12, 2020Front Gate7.1
Nov 29, 2019Front Gate7
Jan 17, 2019Front Gate7
Jan 8, 2018Front Gate7
Feb 17, 2017Front Gate6
Jan 5, 2016Front Gate7

Suspended solids

0.6 mg/L2 results

100 mg/L

All results for suspended solids

Mud and fine particles that cloud water, bury habitat, and carry other pollutants.

11 results as a table
SampledDrainage areaResult
Dec 24, 2025Front Gate1.2 mg/L
Nov 14, 2025Front GateNot detected
Apr 3, 2025Front Gate4 mg/L
Mar 28, 2022Front Gate1 mg/L
Oct 25, 2021Front Gate2 mg/L
Mar 12, 2020Front Gate9 mg/L
Nov 29, 2019Front GateNot detected
Jan 17, 2019Front Gate1 mg/L
Jan 8, 2018Front GateNot detected
Feb 17, 2017Front GateNot detected
Jan 5, 2016Front Gate14 mg/L

Oil and grease

0.45 mg/L2 results

15 mg/L

All results for oil and grease

Coats plants and animals and blocks oxygen from entering the water.

11 results as a table
SampledDrainage areaResult
Dec 24, 2025Front GateNot detected
Nov 14, 2025Front Gate0.9 mg/L
Apr 3, 2025Front GateNot detected
Mar 28, 2022Front GateNot detected
Oct 25, 2021Front GateNot detected
Mar 12, 2020Front GateNot detected
Nov 29, 2019Front GateNot detected
Jan 17, 2019Front GateNot detected
Jan 8, 2018Front GateNot detected
Feb 17, 2017Front GateNot detected
Jan 5, 2016Front GateNot detected

Copper

0.0011 mg/L2 results

0.0332 mg/L

All results for copper

Toxic to fish at very low concentrations and damages their sense of smell.

3 results as a table
SampledDrainage areaResult
Dec 24, 2025Front Gate0.00096 mg/L
Nov 14, 2025Front Gate0.0012 mg/L
Feb 17, 2017Front Gate0.0009 mg/L

Lead

0.00018 mg/L2 results

0.262 mg/L

All results for lead

A nerve poison for people and wildlife that builds up in sediment.

11 results as a table
SampledDrainage areaResult
Dec 24, 2025Front GateNot detected
Nov 14, 2025Front Gate0.00037 mg/L
Apr 3, 2025Front Gate0.00088 mg/L
Mar 28, 2022Front Gate0.0007 mg/L
Oct 25, 2021Front Gate0.0034 mg/L
Mar 12, 2020Front Gate0.0022 mg/L
Nov 29, 2019Front Gate0.0002 mg/L
Jan 17, 2019Front GateNot detected
Jan 8, 2018Front GateNot detected
Feb 17, 2017Front Gate0.0006 mg/L
Jan 5, 2016Front Gate0.056 mg/L

Iron

Not detected2 results

1 mg/L

All results for iron

Settles out as rust-colored sludge that smothers creek beds. The state took its iron benchmark from a 2008 EPA benchmark that the EPA has since stopped using.

11 results as a table
SampledDrainage areaResult
Dec 24, 2025Front GateNot detected
Nov 14, 2025Front GateNot detected
Apr 3, 2025Front Gate0.1 mg/L
Mar 28, 2022Front Gate0.04 mg/L
Oct 25, 2021Front Gate0.23 mg/L
Mar 12, 2020Front Gate0.19 mg/L
Nov 29, 2019Front GateNot detected
Jan 17, 2019Front Gate0.11 mg/L
Jan 8, 2018Front Gate0.05 mg/L
Feb 17, 2017Front GateNot detected
Jan 5, 2016Front Gate0.74 mg/L

Stricter limits under the Los Angeles River Metals cleanup plan

This site drains to Los Angeles River and Los Angeles River Tributaries, which has a cleanup plan. These apply to single results, not yearly averages. Two or more results over in a year count as an exceedance.

PollutantLimitResults over in 2025-26
Copper0.06749 mg/L0 of 2Becomes a legal limit on Jul 1, 2020
Lead0.094 mg/L0 of 2Becomes a legal limit on Jul 1, 2020
Zinc0.159 mg/L0 of 2Becomes a legal limit on Jul 1, 2020

Rain and sampling by year

The permit asks each site to sample two storms between July and December and two between January and June. When a site samples fewer, its results may not represent its true runoff.

  • Day with rain
  • Day sampled
2025-26

2 of 10 storms sampledTold the state: not enough qualifying storms occurred

2024-25

0 of 6 storms sampledTold the state it did not sample every required storm

2023-24

0 of 14 storms sampledTold the state it did not sample every required storm

2022-23

0 of 18 storms sampledTold the state it did not sample every required storm

2021-22

2 of 8 storms sampledTold the state it did not sample every required storm

2020-21

0 of 5 storms sampledTold the state it did not sample every required storm

Rainfall comes from the daily records of NOAA station Burbank Glendale Pasadena Airport (USW00023152), 2.5 miles from the site. It is the nearest station with a full record since 2015. A storm here means a tenth of an inch or more of rain after two dry days.

Location and details

Where the runoff goes

The facility reports that rain running off it drains to Burbank Western Channel.

The site sits in a watershed with a state cleanup plan for metals and nutrients.

Storm drains carry this runoff to creeks and the ocean without treatment.

The neighborhood

About 2,436 people live in the neighborhood around this site in Sun Valley. The state scores it above 96% of California neighborhoods for pollution burden and health vulnerability.

Least burdenedMost burdened

Source: CalEnviroScreen 5.0, census tract 6037121102. The score covers the whole neighborhood and does not measure this site's own effect.

Permits and IDs

Industry
Motor Vehicle Parts, Used
Operator
Green Light Used Auto Parts Inc
Covered by
Industrial stormwater permit
Stormwater permit since
November 2008
Site size
25800 square feet
Paved or roofed
100% of the site
State stormwater ID
4 19I021924

The state stormwater record

Report pollution at this site

Send photos or video of what you have seen, such as smoke, runoff, or uncovered materials. We review every report.

Send a report