EarthSpotterEarthSpotter

Holiday Porcelain Enamel Co

13839 Marquardt Ave, Santa Fe Springs, CA 90670

Bregin Inc has held an industrial stormwater permit for the site since May 2003. Its industry is listed as electroplating, plating, polishing, anodizing, and coloring. The permit requires samples of its runoff, and the last one it filed is from February 2025. Its runoff drains to R4 - Coyote Creek and its tributary/ies, where a state cleanup plan sets stricter limits for copper and zinc.

13839 Marquardt Ave, Santa Fe Springs

Industrial stormwater

This site filed no samples of its runoff in the 2025-2026 reporting year, although rain records show 8 storms of a tenth of an inch or more near it.

The permit requires samples in each half of the year, July to December and January to June. The last sample it filed is from February 2025.

Clean WaterIndustrial stormwater

Missing samples

Clean Water Act. Source: California State Water Resources Control Board, data as of November 23, 2026.

Rain and sampling in 2024-25

The facility sampled 1 of the 6 storms of a tenth of an inch or more near the site in 2024-25.

The permit generally requires samples from four storms a year, with few exceptions.

What the samples show

The state compares each year's average with its benchmark. A site with more than one drainage area samples each one separately, so it can file more than four results for a pollutant in a year. Open a pollutant to see every lab result behind the averages.

  • Yearly average, over
  • Yearly average, within
  • Single lab result
  • State benchmark

Tested in 2024-25

pH

7.3 to 7.32 results, 2 drainage areas

6 to 9

All results for pH

Water that is too acidic or too alkaline harms aquatic life and makes metals more toxic.

2024-25 results by drainage area

The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.

Drainage areaResultsLowestHighest
Front Downspouts17.37.3
Rear Downspouts17.37.3
24 results as a table
SampledDrainage areaResult
Feb 13, 2025Rear Downspouts7.3
Feb 13, 2025Front Downspouts7.3
Mar 2, 2024Rear Downspouts7.1
Mar 2, 2024Front Downspouts7.5
Jan 5, 2023Rear Downspouts7.1
Jan 5, 2023Front Downspouts7.1
Dec 12, 2022Rear Downspouts7.2
Dec 12, 2022Front Downspouts7.1
Mar 28, 2022Rear Downspouts6.9
Mar 28, 2022Front Downspouts6.9
Dec 14, 2021Rear Downspouts6.9
Dec 14, 2021Front Downspouts6.9
Dec 4, 2019Rear Downspouts7.3
Dec 4, 2019Front Downspouts7.3
Feb 14, 2019Rear Downspouts7.2
Feb 14, 2019Front Downspouts7.2
Jan 14, 2019Rear Downspouts7.4
Jan 14, 2019Front Downspouts7.5
Feb 17, 2017Rear Downspouts7
Feb 17, 2017Front Downspouts7
Dec 21, 2016Rear Downspouts7
Dec 21, 2016Front Downspouts7.1
Jan 5, 2016Rear Downspouts7.2
Jan 5, 2016Front Downspouts7.4

Suspended solids

2.4 mg/L2 results, 2 drainage areas

100 mg/L

All results for suspended solids

Mud and fine particles that cloud water, bury habitat, and carry other pollutants.

2024-25 results by drainage area

The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.

Drainage areaResultsAverageHighest
Front Downspouts14 mg/L4 mg/L
Rear Downspouts10.8 mg/L0.8 mg/L
24 results as a table
SampledDrainage areaResult
Feb 13, 2025Rear Downspouts0.8 mg/L
Feb 13, 2025Front Downspouts4 mg/L
Mar 2, 2024Rear Downspouts5 mg/L
Mar 2, 2024Front Downspouts3 mg/L
Jan 5, 2023Rear DownspoutsNot detected
Jan 5, 2023Front DownspoutsNot detected
Dec 12, 2022Rear Downspouts4 mg/L
Dec 12, 2022Front Downspouts7 mg/L
Mar 28, 2022Rear Downspouts2 mg/L
Mar 28, 2022Front Downspouts1 mg/L
Dec 14, 2021Rear Downspouts7 mg/L
Dec 14, 2021Front Downspouts4 mg/L
Dec 4, 2019Rear Downspouts13 mg/L
Dec 4, 2019Front Downspouts12 mg/L
Feb 14, 2019Rear Downspouts3 mg/L
Feb 14, 2019Front Downspouts6 mg/L
Jan 14, 2019Rear Downspouts33 mg/L
Jan 14, 2019Front Downspouts15 mg/L
Feb 17, 2017Rear Downspouts24 mg/L
Feb 17, 2017Front Downspouts21 mg/L
Dec 21, 2016Rear Downspouts16 mg/L
Dec 21, 2016Front Downspouts63 mg/L
Jan 5, 2016Rear Downspouts24 mg/L
Jan 5, 2016Front Downspouts13 mg/L

Oil and grease

Not detected2 results, 2 drainage areas

15 mg/L

All results for oil and grease

Coats plants and animals and blocks oxygen from entering the water.

2024-25 results by drainage area

The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.

Drainage areaResultsAverageHighest
Front Downspouts10 mg/L0 mg/L
Rear Downspouts10 mg/L0 mg/L
24 results as a table
SampledDrainage areaResult
Feb 13, 2025Rear DownspoutsNot detected
Feb 13, 2025Front DownspoutsNot detected
Mar 2, 2024Rear DownspoutsNot detected
Mar 2, 2024Front DownspoutsNot detected
Jan 5, 2023Rear DownspoutsNot detected
Jan 5, 2023Front DownspoutsNot detected
Dec 12, 2022Rear DownspoutsNot detected
Dec 12, 2022Front DownspoutsNot detected
Mar 28, 2022Rear DownspoutsNot detected
Mar 28, 2022Front Downspouts1 mg/L
Dec 14, 2021Rear DownspoutsNot detected
Dec 14, 2021Front DownspoutsNot detected
Dec 4, 2019Rear DownspoutsNot detected
Dec 4, 2019Front DownspoutsNot detected
Feb 14, 2019Rear Downspouts3 mg/L
Feb 14, 2019Front Downspouts2 mg/L
Jan 14, 2019Rear DownspoutsNot detected
Jan 14, 2019Front Downspouts2 mg/L
Feb 17, 2017Rear Downspouts2 mg/L
Feb 17, 2017Front DownspoutsNot detected
Dec 21, 2016Rear Downspouts2 mg/L
Dec 21, 2016Front Downspouts2 mg/L
Jan 5, 2016Rear Downspouts5 mg/L
Jan 5, 2016Front Downspouts5 mg/L

Zinc

Not detected2 results, 2 drainage areas

0.26 mg/L

All results for zinc

Toxic to fish and the small animals they eat, even at low concentrations.

2024-25 results by drainage area

The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.

Drainage areaResultsAverageHighest
Front Downspouts10 mg/L0 mg/L
Rear Downspouts10 mg/L0 mg/L
24 results as a table
SampledDrainage areaResult
Feb 13, 2025Rear DownspoutsNot detected
Feb 13, 2025Front DownspoutsNot detected
Mar 2, 2024Rear Downspouts0.027 mg/L
Mar 2, 2024Front Downspouts0.018 mg/L
Jan 5, 2023Rear Downspouts0.0048 mg/L
Jan 5, 2023Front Downspouts0.0068 mg/L
Dec 12, 2022Rear Downspouts0.012 mg/L
Dec 12, 2022Front Downspouts0.0096 mg/L
Mar 28, 2022Rear Downspouts0.082 mg/L
Mar 28, 2022Front Downspouts0.054 mg/L
Dec 14, 2021Rear Downspouts0.082 mg/L
Dec 14, 2021Front Downspouts0.081 mg/L
Dec 4, 2019Rear Downspouts0.18 mg/L
Dec 4, 2019Front Downspouts0.18 mg/L
Feb 14, 2019Rear Downspouts0.065 mg/L
Feb 14, 2019Front Downspouts0.067 mg/L
Jan 14, 2019Rear Downspouts0.11 mg/L
Jan 14, 2019Front Downspouts0.11 mg/L
Feb 17, 2017Rear Downspouts0.081 mg/L
Feb 17, 2017Front Downspouts0.081 mg/L
Dec 21, 2016Rear Downspouts0.1 mg/L
Dec 21, 2016Front Downspouts0.12 mg/L
Jan 5, 2016Rear Downspouts0.17 mg/L
Jan 5, 2016Front Downspouts0.085 mg/L

Copper

0.0014 mg/L2 results, 2 drainage areas

0.0332 mg/L

All results for copper

Toxic to fish at very low concentrations and damages their sense of smell.

2024-25 results by drainage area

The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.

Drainage areaResultsAverageHighest
Front Downspouts10.0016 mg/L0.0016 mg/L
Rear Downspouts10.0013 mg/L0.0013 mg/L
22 results as a table
SampledDrainage areaResult
Feb 13, 2025Rear Downspouts0.0013 mg/L
Feb 13, 2025Front Downspouts0.0016 mg/L
Mar 2, 2024Rear Downspouts0.0019 mg/L
Mar 2, 2024Front Downspouts0.0021 mg/L
Jan 5, 2023Rear Downspouts0.0017 mg/L
Jan 5, 2023Front Downspouts0.0018 mg/L
Dec 12, 2022Rear Downspouts0.0049 mg/L
Dec 12, 2022Front Downspouts0.0039 mg/L
Mar 28, 2022Rear Downspouts0.0075 mg/L
Mar 28, 2022Front Downspouts0.0071 mg/L
Dec 14, 2021Rear Downspouts0.011 mg/L
Dec 14, 2021Front Downspouts0.0094 mg/L
Dec 4, 2019Rear Downspouts0.012 mg/L
Dec 4, 2019Front Downspouts0.013 mg/L
Feb 14, 2019Rear Downspouts0.0013 mg/L
Feb 14, 2019Front Downspouts0.0012 mg/L
Jan 14, 2019Rear Downspouts0.01 mg/L
Jan 14, 2019Front Downspouts0.011 mg/L
Feb 17, 2017Rear Downspouts0.023 mg/L
Feb 17, 2017Front Downspouts0.014 mg/L
Dec 21, 2016Rear Downspouts0.014 mg/L
Dec 21, 2016Front Downspouts0.017 mg/L

Iron

Not detected2 results, 2 drainage areas

1 mg/L

All results for iron

Settles out as rust-colored sludge that smothers creek beds. The state took its iron benchmark from a 2008 EPA benchmark that the EPA has since stopped using.

2024-25 results by drainage area

The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.

Drainage areaResultsAverageHighest
Front Downspouts10 mg/L0 mg/L
Rear Downspouts10 mg/L0 mg/L
24 results as a table
SampledDrainage areaResult
Feb 13, 2025Rear DownspoutsNot detected
Feb 13, 2025Front DownspoutsNot detected
Mar 2, 2024Rear DownspoutsNot detected
Mar 2, 2024Front DownspoutsNot detected
Jan 5, 2023Rear Downspouts0.19 mg/L
Jan 5, 2023Front Downspouts0.21 mg/L
Dec 12, 2022Rear Downspouts0.23 mg/L
Dec 12, 2022Front Downspouts0.2 mg/L
Mar 28, 2022Rear Downspouts0.05 mg/L
Mar 28, 2022Front Downspouts0.04 mg/L
Dec 14, 2021Rear Downspouts0.17 mg/L
Dec 14, 2021Front Downspouts0.19 mg/L
Dec 4, 2019Rear Downspouts0.25 mg/L
Dec 4, 2019Front Downspouts0.17 mg/L
Feb 14, 2019Rear DownspoutsNot detected
Feb 14, 2019Front DownspoutsNot detected
Jan 14, 2019Rear Downspouts0.22 mg/L
Jan 14, 2019Front Downspouts0.26 mg/L
Feb 17, 2017Rear Downspouts0.29 mg/L
Feb 17, 2017Front Downspouts0.16 mg/L
Dec 21, 2016Rear Downspouts0.5 mg/L
Dec 21, 2016Front Downspouts0.77 mg/L
Jan 5, 2016Rear Downspouts0.97 mg/L
Jan 5, 2016Front Downspouts0.93 mg/L

Aluminum

0.0067 mg/L2 results, 2 drainage areas

0.75 mg/L

All results for aluminum

Toxic to fish and aquatic insects. It builds up on gills.

2024-25 results by drainage area

The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.

Drainage areaResultsAverageHighest
Front Downspouts10.0082 mg/L0.0082 mg/L
Rear Downspouts10.0053 mg/L0.0053 mg/L
24 results as a table
SampledDrainage areaResult
Feb 13, 2025Rear Downspouts0.0053 mg/L
Feb 13, 2025Front Downspouts0.0082 mg/L
Mar 2, 2024Rear Downspouts0.066 mg/L
Mar 2, 2024Front Downspouts0.025 mg/L
Jan 5, 2023Rear Downspouts0.15 mg/L
Jan 5, 2023Front Downspouts0.15 mg/L
Dec 12, 2022Rear Downspouts0.16 mg/L
Dec 12, 2022Front Downspouts0.14 mg/L
Mar 28, 2022Rear Downspouts0.066 mg/L
Mar 28, 2022Front Downspouts0.021 mg/L
Dec 14, 2021Rear Downspouts0.21 mg/L
Dec 14, 2021Front Downspouts0.24 mg/L
Dec 4, 2019Rear Downspouts0.24 mg/L
Dec 4, 2019Front Downspouts0.3 mg/L
Feb 14, 2019Rear Downspouts0.016 mg/L
Feb 14, 2019Front Downspouts0.0059 mg/L
Jan 14, 2019Rear Downspouts0.033 mg/L
Jan 14, 2019Front Downspouts0.032 mg/L
Feb 17, 2017Rear Downspouts0.18 mg/L
Feb 17, 2017Front Downspouts0.079 mg/L
Dec 21, 2016Rear Downspouts0.42 mg/L
Dec 21, 2016Front Downspouts0.49 mg/L
Jan 5, 2016Rear Downspouts0.43 mg/L
Jan 5, 2016Front Downspouts0.36 mg/L

Nitrate and nitrite

0.25 mg/L2 results, 2 drainage areas

0.68 mg/L

All results for nitrate and nitrite

Feeds algae blooms that strip oxygen from creeks and lagoons.

2024-25 results by drainage area

The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.

Drainage areaResultsAverageHighest
Front Downspouts10.26 mg/L0.26 mg/L
Rear Downspouts10.24 mg/L0.24 mg/L
24 results as a table
SampledDrainage areaResult
Feb 13, 2025Rear Downspouts0.24 mg/L
Feb 13, 2025Front Downspouts0.26 mg/L
Mar 2, 2024Rear Downspouts0.18 mg/L
Mar 2, 2024Front Downspouts0.15 mg/L
Jan 5, 2023Rear Downspouts0.22 mg/L
Jan 5, 2023Front Downspouts0.22 mg/L
Dec 12, 2022Rear Downspouts0.49 mg/L
Dec 12, 2022Front Downspouts0.38 mg/L
Mar 28, 2022Rear Downspouts0.02 mg/L
Mar 28, 2022Front Downspouts0.06 mg/L
Dec 14, 2021Rear Downspouts0.51 mg/L
Dec 14, 2021Front Downspouts0.44 mg/L
Dec 4, 2019Rear Downspouts0.16 mg/L
Dec 4, 2019Front Downspouts0.21 mg/L
Feb 14, 2019Rear Downspouts0.03 mg/L
Feb 14, 2019Front Downspouts0.03 mg/L
Jan 14, 2019Rear Downspouts0.17 mg/L
Jan 14, 2019Front Downspouts0.17 mg/L
Feb 17, 2017Rear Downspouts0.17 mg/L
Feb 17, 2017Front Downspouts0.23 mg/L
Dec 21, 2016Rear Downspouts0.24 mg/L
Dec 21, 2016Front Downspouts0.27 mg/L
Jan 5, 2016Rear Downspouts0.17 mg/L
Jan 5, 2016Front Downspouts0.17 mg/L

Nickel

0.0036 mg/L2 results, 2 drainage areas

1.02 mg/L

All results for nickel

2024-25 results by drainage area

The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.

Drainage areaResultsAverageHighest
Front Downspouts10.0043 mg/L0.0043 mg/L
Rear Downspouts10.0029 mg/L0.0029 mg/L
22 results as a table
SampledDrainage areaResult
Feb 13, 2025Rear Downspouts0.0029 mg/L
Feb 13, 2025Front Downspouts0.0043 mg/L
Mar 2, 2024Rear Downspouts0.0041 mg/L
Mar 2, 2024Front Downspouts0.0013 mg/L
Jan 5, 2023Rear Downspouts0.0007 mg/L
Jan 5, 2023Front Downspouts0.0008 mg/L
Dec 12, 2022Rear Downspouts0.0013 mg/L
Dec 12, 2022Front Downspouts0.001 mg/L
Mar 28, 2022Rear Downspouts0.0045 mg/L
Mar 28, 2022Front Downspouts0.0032 mg/L
Dec 14, 2021Rear Downspouts0.0053 mg/L
Dec 14, 2021Front Downspouts0.0059 mg/L
Dec 4, 2019Rear Downspouts0.0057 mg/L
Dec 4, 2019Front Downspouts0.0065 mg/L
Feb 14, 2019Rear Downspouts0.0005 mg/L
Feb 14, 2019Front Downspouts0.0005 mg/L
Jan 14, 2019Rear Downspouts0.0014 mg/L
Jan 14, 2019Front Downspouts0.0022 mg/L
Feb 17, 2017Rear Downspouts0.024 mg/L
Feb 17, 2017Front Downspouts0.0023 mg/L
Dec 21, 2016Rear Downspouts0.0044 mg/L
Dec 21, 2016Front Downspouts0.0071 mg/L

Also tested, with no state benchmark to compare against: 24 results for chromium and 22 for dissolved copper.

Stricter limits under the R4 - San Gabriel River Metals and Selenium cleanup plan

This site drains to R4 - Coyote Creek and its tributary/ies, which has a cleanup plan. These apply to single results, not yearly averages. Two or more results over in a year count as an exceedance.

PollutantLimitResults over in 2024-25
Copper0.027 mg/L0 of 2Becomes a legal limit on Jul 1, 2020
Zinc0.158 mg/L0 of 2Becomes a legal limit on Jul 1, 2020

Rain and sampling by year

The permit asks each site to sample two storms between July and December and two between January and June. When a site samples fewer, its results may not represent its true runoff.

  • Day with rain
  • Day sampled
2025-26

0 of 8 storms sampledTold the state it did not sample every required storm

2024-25

1 of 6 storms sampledTold the state it did not sample every required storm

2023-24

1 of 15 storms sampledTold the state it did not sample every required storm

2022-23

2 of 18 storms sampledTold the state it sampled every required storm

2021-22

2 of 10 storms sampledTold the state it sampled every required storm

2020-21

0 of 7 storms sampledTold the state it did not sample every required storm

Rainfall comes from the daily records of NOAA station Fullerton Municipal Airport (USW00003166), 3.8 miles from the site. It is the nearest station with a full record since 2015. A storm here means a tenth of an inch or more of rain after two dry days.

Location and details

Where the runoff goes

The facility reports that rain running off it drains to North Fork Coyote Creek.

The site sits in a watershed with a state cleanup plan for metals and selenium.

Storm drains carry this runoff to creeks and the ocean without treatment.

Permits and IDs

Industry
Electroplating, Plating, Polishing, Anodizing, and Coloring
Operator
Bregin Inc
Covered by
Industrial stormwater permit
Stormwater permit since
May 2003
Site size
3 acres
State stormwater ID
4 19I018162

The state stormwater record

Report pollution at this site

Send photos or video of what you have seen, such as smoke, runoff, or uncovered materials. We review every report.