Milans Auto Inc has held an industrial stormwater permit for the site since April 2003. Its industry is listed as motor vehicle parts, used. The permit requires samples of its runoff, and the last one it filed is from February 2024. Under its stormwater permit it is at Exceedance Response Action Level 1 for zinc and copper, and the site is in a watershed with a state cleanup plan for toxic and metals.
225 E Harry Bridges Blvd, Wilmington
Industrial stormwater
This site filed no samples of its runoff in the 2025-2026 reporting year, although rain records show 7 storms of a tenth of an inch or more near it.
The permit requires samples in each half of the year, July to December and January to June. The last sample it filed is from February 2024.
Clean WaterIndustrial stormwater
Missing samples
Clean Water Act. Source: California State Water Resources Control Board, data as of November 23, 2026.
Rain and sampling in 2023-24
The facility sampled 1 of the 14 storms of a tenth of an inch or more near the site in 2023-24.
The permit generally requires samples from four storms a year, with few exceptions.
What the samples show
The state compares each year's average with its benchmark. A site with more than one drainage area samples each one separately, so it can file more than four results for a pollutant in a year. Open a pollutant to see every lab result behind the averages.
Yearly average, over
Yearly average, within
Single lab result
State benchmark
Tested in 2023-24
Pollutant2023-24 averageBenchmarkLast five years
Zinc
0.0056 mg/L1 result
0.26 mg/L
Over in 1 of 3 years tested
Exceedance Response Action Level 1
All results for zinc
Toxic to fish and the small animals they eat, even at low concentrations.
3 results as a table
Sampled
Drainage area
Result
Feb 19, 2024
DP 1
0.0056 mg/L
Dec 27, 2022
DP 1
0.28 mg/L
Dec 23, 2021
DP 1
0.062 mg/L
Copper
0.001 mg/L1 result
0.0332 mg/L
Over in 1 of 3 years tested
Exceedance Response Action Level 1
All results for copper
Toxic to fish at very low concentrations and damages their sense of smell.
3 results as a table
Sampled
Drainage area
Result
Feb 19, 2024
DP 1
0.001 mg/L
Dec 27, 2022
DP 1
0.036 mg/L
Dec 23, 2021
DP 1
0.0019 mg/L
pH
7 to 71 result
6 to 9
Over in 0 of 3 years tested
All results for pH
Water that is too acidic or too alkaline harms aquatic life and makes metals more toxic.
4 results as a table
Sampled
Drainage area
Result
Feb 19, 2024
DP 1
7
Dec 27, 2022
DP 1
7
Dec 23, 2021
DP 1
7
Dec 23, 2015
DP 1
7
Suspended solids
Not detected1 result
100 mg/L
Over in 0 of 3 years tested
All results for suspended solids
Mud and fine particles that cloud water, bury habitat, and carry other pollutants.
4 results as a table
Sampled
Drainage area
Result
Feb 19, 2024
DP 1
Not detected
Dec 27, 2022
DP 1
4 mg/L
Dec 23, 2021
DP 1
1 mg/L
Dec 23, 2015
DP 1
4.7 mg/L
Oil and grease
3 mg/L1 result
15 mg/L
Over in 0 of 3 years tested
All results for oil and grease
Coats plants and animals and blocks oxygen from entering the water.
4 results as a table
Sampled
Drainage area
Result
Feb 19, 2024
DP 1
3 mg/L
Dec 27, 2022
DP 1
Not detected
Dec 23, 2021
DP 1
1 mg/L
Dec 23, 2015
DP 1
Not detected
Lead
Not detected1 result
0.262 mg/L
Over in 0 of 3 years tested
All results for lead
A nerve poison for people and wildlife that builds up in sediment.
4 results as a table
Sampled
Drainage area
Result
Feb 19, 2024
DP 1
Not detected
Dec 27, 2022
DP 1
0.0007 mg/L
Dec 23, 2021
DP 1
0.0005 mg/L
Dec 23, 2015
DP 1
0.012 mg/L
Iron
Not detected1 result
1 mg/L
Over in 0 of 3 years tested
All results for iron
Settles out as rust-colored sludge that smothers creek beds. The state took its iron benchmark from a 2008 EPA benchmark that the EPA has since stopped using.
4 results as a table
Sampled
Drainage area
Result
Feb 19, 2024
DP 1
Not detected
Dec 27, 2022
DP 1
0.07 mg/L
Dec 23, 2021
DP 1
0.04 mg/L
Dec 23, 2015
DP 1
0.48 mg/L
Aluminum
0.0046 mg/L1 result
0.75 mg/L
Over in 0 of 3 years tested
All results for aluminum
Toxic to fish and aquatic insects. It builds up on gills.
4 results as a table
Sampled
Drainage area
Result
Feb 19, 2024
DP 1
0.0046 mg/L
Dec 27, 2022
DP 1
0.04 mg/L
Dec 23, 2021
DP 1
0.026 mg/L
Dec 23, 2015
DP 1
0.26 mg/L
Tested once or twice and within the benchmark: cadmium.
Rain and sampling by year
The permit asks each site to sample two storms between July and December and two between January and June. When a site samples fewer, its results may not represent its true runoff.
Day with rain
Day sampled
2025-26
0 of 7 storms sampledTold the state: no trained staff were available
2024-25
0 of 8 storms sampledTold the state it did not sample every required storm
2023-24
1 of 14 storms sampledTold the state it did not sample every required storm
2022-23
1 of 17 storms sampledTold the state it did not sample every required storm
2021-22
1 of 8 storms sampledTold the state it did not sample every required storm
2020-21
0 of 6 storms sampledTold the state it did not sample every required storm
JulAugSepOctNovDecJanFebMarAprMayJun
Rainfall comes from the daily records of NOAA station Torrance Airport (USW00003122), 5.1 miles from the site. It is the nearest station with a full record since 2015. A storm here means a tenth of an inch or more of rain after two dry days.
Location and details
Where the runoff goes
The facility reports that rain running off it drains to Los Angeles Harbor.
The site sits in a watershed with a state cleanup plan for toxic and metals.
Storm drains carry this runoff to creeks and the ocean without treatment.
The neighborhood
About 2,987 people live in the neighborhood around this site in Wilmington. The state scores it above 100% of California neighborhoods for pollution burden and health vulnerability.
Least burdenedMost burdened
Source: CalEnviroScreen 5.0, census tract 6037294701. The score covers the whole neighborhood and does not measure this site's own effect.