EarthSpotterEarthSpotter

Frank Smith Masonry

2830 Pomona Blvd, Pomona, CA 91768

Frank Smith Masonry has held an industrial stormwater permit for the site since March 2003. Its industry is listed as concrete block and brick. Every pollutant it tested in 2025-26 averaged within the state benchmarks; it was over a benchmark in 1 of the 4 years it sampled in the last five. Under its stormwater permit it is at Exceedance Response Action Level 1 for iron, and the site is in a watershed with a state cleanup plan for metals and selenium.

2830 Pomona Blvd, Pomona

Industrial stormwater

During the 2025-2026 rainy season, every pollutant this site tested in its runoff averaged within the state's benchmarks.

That is based on 6 lab results from 2 storm days. It exceeded a benchmark in 1 of the last 4 years it sampled.

Clean WaterIndustrial stormwater

Within the state benchmarks

Clean Water Act. Source: California State Water Resources Control Board, data as of November 23, 2026.

Rain and sampling in 2025-26

The facility sampled 1 of the 11 storms of a tenth of an inch or more near the site in 2025-26.

The permit generally requires samples from four storms a year, with few exceptions. The facility told the state it missed storms because not enough qualifying storms occurred and storms fell outside operating hours.

What the samples show

The state compares each year's average with its benchmark. A site with more than one drainage area samples each one separately, so it can file more than four results for a pollutant in a year. Open a pollutant to see every lab result behind the averages.

  • Yearly average, over
  • Yearly average, within
  • Single lab result
  • State benchmark

Tested in 2025-26

Iron

0.17 mg/L2 results

1 mg/L

Exceedance Response Action Level 1

All results for iron

Settles out as rust-colored sludge that smothers creek beds. The state took its iron benchmark from a 2008 EPA benchmark that the EPA has since stopped using.

15 results as a table
SampledDrainage areaResult
Jan 16, 2026SP-10.14 mg/L
Nov 15, 2025SP-10.21 mg/L
Mar 12, 2025SP-12.8 mg/L
Nov 8, 2022SP-10.26 mg/L
Dec 24, 2021SP-10.77 mg/L
Dec 28, 2020SP-1Not detected
Dec 4, 2019SP-1Not detected
Jan 14, 2019SP-10.12 mg/L
Dec 6, 2018SP-10.23 mg/L
Nov 29, 2018SP-12.1 mg/L
Jan 9, 2018SP-1Not detected
Dec 22, 2016SP-10.42 mg/L
Jan 31, 2016SP-11 mg/L
Jan 6, 2016SP-10.21 mg/L
Sep 15, 2015SP-10.93 mg/L

pH

7.5 to 7.51 result

6 to 9

All results for pH

Water that is too acidic or too alkaline harms aquatic life and makes metals more toxic.

13 results as a table
SampledDrainage areaResult
Nov 15, 2025SP-17.5
Mar 12, 2025SP-17
Nov 8, 2022SP-16
Dec 24, 2021SP-17
Dec 28, 2020SP-17
Dec 4, 2019SP-14
Jan 14, 2019SP-16.3
Nov 29, 2018SP-17
Jan 9, 2018SP-17
Dec 22, 2016SP-16
Jan 31, 2016SP-17.3
Jan 6, 2016SP-17.1
Sep 15, 2015SP-17.1

Suspended solids

8.2 mg/L1 result

100 mg/L

All results for suspended solids

Mud and fine particles that cloud water, bury habitat, and carry other pollutants.

11 results as a table
SampledDrainage areaResult
Nov 15, 2025SP-18.2 mg/L
Mar 12, 2025SP-15 mg/L
Nov 8, 2022SP-14.1 mg/L
Dec 24, 2021SP-121 mg/L
Dec 28, 2020SP-13.7 mg/L
Jan 14, 2019SP-14.9 mg/L
Jan 9, 2018SP-150 mg/L
Dec 22, 2016SP-114 mg/L
Jan 31, 2016SP-146 mg/L
Jan 6, 2016SP-17.6 mg/L
Sep 15, 2015SP-138 mg/L

Oil and grease

1.9 mg/L2 results

15 mg/L

All results for oil and grease

Coats plants and animals and blocks oxygen from entering the water.

15 results as a table
SampledDrainage areaResult
Jan 16, 2026SP-11.5 mg/L
Nov 15, 2025SP-12.3 mg/L
Mar 12, 2025SP-1Not detected
Nov 8, 2022SP-1Not detected
Dec 24, 2021SP-11.5 mg/L
Dec 28, 2020SP-111 mg/L
Dec 4, 2019SP-1Not detected
Jan 14, 2019SP-1Not detected
Dec 6, 2018SP-1Not detected
Nov 29, 2018SP-1Not detected
Jan 9, 2018SP-1Not detected
Dec 22, 2016SP-11.8 mg/L
Jan 31, 2016SP-13.5 mg/L
Jan 6, 2016SP-1Not detected
Sep 15, 2015SP-1Not detected

Rain and sampling by year

The permit asks each site to sample two storms between July and December and two between January and June. When a site samples fewer, its results may not represent its true runoff.

  • Day with rain
  • Day sampled
2025-26

1 of 11 storms sampledTold the state: not enough qualifying storms occurred; storms fell outside operating hours

2024-25

1 of 7 storms sampledTold the state it did not sample every required storm

2023-24

0 of 16 storms sampledTold the state it did not sample every required storm

2022-23

1 of 21 storms sampledTold the state it did not sample every required storm

2021-22

1 of 9 storms sampledTold the state it did not sample every required storm

2020-21

1 of 6 storms sampledTold the state it did not sample every required storm

Rainfall comes from the daily records of NOAA station Covina City Yard Fc387b (USC00042090), 5.2 miles from the site. It is the nearest station with a full record since 2015. A storm here means a tenth of an inch or more of rain after two dry days.

Location and details

Where the runoff goes

The facility reports that rain running off it drains to San Jose Creek Flood Channel.

The site sits in a watershed with a state cleanup plan for metals and selenium.

Storm drains carry this runoff to creeks and the ocean without treatment.

The neighborhood

About 7,618 people live in the neighborhood around this site in Pomona. The state scores it above 98% of California neighborhoods for pollution burden and health vulnerability.

Least burdenedMost burdened

Source: CalEnviroScreen 5.0, census tract 6037409000. The score covers the whole neighborhood and does not measure this site's own effect.

Permits and IDs

Industry
Concrete Block and Brick
Operator
Frank Smith Masonry
Covered by
Industrial stormwater permit
Stormwater permit since
March 2003
Site size
43000 square feet
State stormwater ID
4 19I017867

The state stormwater record

Report pollution at this site

Send photos or video of what you have seen, such as smoke, runoff, or uncovered materials. We review every report.

Send a report