EarthSpotterEarthSpotter

Lancast Alumnium Inc

1604 W 139th St, Gardena, CA 90249

Lancast Alumnium Inc has held an industrial stormwater permit for the site since July 1998. Its industry is listed as aluminum foundries. The permit requires samples of its runoff, and the last one it filed is from January 2019. Under its stormwater permit it is at Exceedance Response Action Level 1 for oil and grease and for copper, and its runoff drains to Dominguez Channel and Torrance Lateral Channel, where a state cleanup plan sets stricter limits for copper and zinc.

1604 W 139th St, Gardena

Industrial stormwater

This site last filed a sample of its runoff in January 2019.

The permit requires testing. It has filed no results for the last three years, so there is no public record of what its runoff contains.

Clean WaterIndustrial stormwater

Missing samples

Clean Water Act. Source: California State Water Resources Control Board, data as of November 23, 2026.

Rain and sampling in 2025-26

The facility sampled none of the 9 storms of a tenth of an inch or more near the site in 2025-26.

The permit generally requires samples from four storms a year, with few exceptions. The facility told the state it missed storms for another reason.

What the samples show

The state compares each year's average with its benchmark. A site with more than one drainage area samples each one separately, so it can file more than four results for a pollutant in a year. Open a pollutant to see every lab result behind the averages.

  • Yearly average, over
  • Yearly average, within
  • Single lab result
  • State benchmark

Not tested in the latest year

Figures are from the last year each was tested.

Oil and grease

3.5 mg/L1 result

15 mg/L

Exceedance Response Action Level 1

All results for oil and grease

Coats plants and animals and blocks oxygen from entering the water.

5 results as a table
SampledDrainage areaResult
Jan 17, 2019Sample Point 13.5 mg/L
Jan 9, 2018Sample Point 121 mg/L
Jan 20, 2017Sample Point 111 mg/L
Dec 22, 2016Sample Point 1Not detected
Jan 5, 2016Sample Point 1Not detected

Copper

0.03 mg/L1 result

0.0332 mg/L

Exceedance Response Action Level 1

All results for copper

Toxic to fish at very low concentrations and damages their sense of smell.

5 results as a table
SampledDrainage areaResult
Jan 17, 2019Sample Point 10.03 mg/L
Jan 9, 2018Sample Point 10.12 mg/L
Jan 20, 2017Sample Point 1Not detected
Dec 22, 2016Sample Point 10.0036 mg/L
Jan 5, 2016Sample Point 10.01 mg/L

pH

7 to 71 result

6 to 9

All results for pH

Water that is too acidic or too alkaline harms aquatic life and makes metals more toxic.

5 results as a table
SampledDrainage areaResult
Jan 17, 2019Sample Point 17
Jan 9, 2018Sample Point 16
Jan 20, 2017Sample Point 16
Dec 22, 2016Sample Point 16
Jan 5, 2016Sample Point 17.5

Suspended solids

0.6 mg/L1 result

100 mg/L

All results for suspended solids

Mud and fine particles that cloud water, bury habitat, and carry other pollutants.

5 results as a table
SampledDrainage areaResult
Jan 17, 2019Sample Point 10.6 mg/L
Jan 9, 2018Sample Point 13.7 mg/L
Jan 20, 2017Sample Point 1Not detected
Dec 22, 2016Sample Point 1Not detected
Jan 5, 2016Sample Point 1Not detected

Zinc

0.015 mg/L1 result

0.26 mg/L

All results for zinc

Toxic to fish and the small animals they eat, even at low concentrations.

5 results as a table
SampledDrainage areaResult
Jan 17, 2019Sample Point 10.015 mg/L
Jan 9, 2018Sample Point 10.0052 mg/L
Jan 20, 2017Sample Point 10.046 mg/L
Dec 22, 2016Sample Point 10.059 mg/L
Jan 5, 2016Sample Point 10.18 mg/L

Aluminum

0.087 mg/L1 result

0.75 mg/L

All results for aluminum

Toxic to fish and aquatic insects. It builds up on gills.

5 results as a table
SampledDrainage areaResult
Jan 17, 2019Sample Point 10.087 mg/L
Jan 9, 2018Sample Point 10.21 mg/L
Jan 20, 2017Sample Point 1Not detected
Dec 22, 2016Sample Point 10.3 mg/L
Jan 5, 2016Sample Point 10.56 mg/L

Stricter limits under the R4 - Los Angeles and Long Beach Harbor Waters cleanup plan

This site drains to Dominguez Channel and Torrance Lateral Channel, which has a cleanup plan. These apply to single results, not yearly averages. Two or more results over in a year count as an exceedance.

PollutantLimitResults over in 2025-26
Copper0.20751 mg/LNot testedBecomes a legal limit on May 5, 2032
Zinc0.89887 mg/LNot testedBecomes a legal limit on May 5, 2032

Rain and sampling by year

The permit asks each site to sample two storms between July and December and two between January and June. When a site samples fewer, its results may not represent its true runoff.

  • Day with rain
  • Day sampled
2025-26

0 of 9 storms sampledTold the state: another reason

2024-25

0 of 6 storms sampledTold the state it did not sample every required storm

2023-24

0 of 14 storms sampledTold the state it did not sample every required storm

2022-23

0 of 17 storms sampledTold the state it did not sample every required storm

2021-22

0 of 6 storms sampledTold the state it did not sample every required storm

2020-21

0 of 6 storms sampledTold the state it did not sample every required storm

Rainfall comes from the daily records of NOAA station Hawthorne Municipal Airport (USW00003167), 2 miles from the site. It is the nearest station with a full record since 2015. A storm here means a tenth of an inch or more of rain after two dry days.

Location and details

Where the runoff goes

The facility has not told the state where its runoff drains.

The site sits in a watershed with a state cleanup plan for toxic and metals.

Storm drains carry this runoff to creeks and the ocean without treatment.

The neighborhood

About 4,670 people live in the neighborhood around this site in Gardena. The state scores it above 94% of California neighborhoods for pollution burden and health vulnerability.

Least burdenedMost burdened

Source: CalEnviroScreen 5.0, census tract 6037602900. The score covers the whole neighborhood and does not measure this site's own effect.

Permits and IDs

Industry
Aluminum Foundries
Operator
Lancast Alumnium Inc
Covered by
Industrial stormwater permit
Stormwater permit since
July 1998
Site size
17490 square feet
State stormwater ID
4 19I014279

The state stormwater record

Report pollution at this site

Send photos or video of what you have seen, such as smoke, runoff, or uncovered materials. We review every report.