3137 E 26th St, Los Angeles, CA 90023

Four Star Chemical has held an industrial stormwater permit for the site since November 1994. Its industry is listed as industrial organic chemicals. The permit requires samples of its runoff, and the last one it filed is from February 2026. The site is in a watershed with a state cleanup plan for metals and nutrients.

3137 E 26th St, Los Angeles

Industrial stormwater

This site filed no samples of its runoff in the 2025-2026 reporting year, although rain records show 9 storms of a tenth of an inch or more near it.

The permit requires samples in each half of the year, July to December and January to June. The last sample it filed is from February 2026.

Clean WaterIndustrial stormwater

Missing samples

Clean Water Act. Source: California State Water Resources Control Board, data as of November 23, 2026.

Rain and sampling in 2025-26

The facility sampled 1 of the 9 storms of a tenth of an inch or more near the site in 2025-26.

The permit generally requires samples from four storms a year, with few exceptions.

What the samples show

The state compares each year's average with its benchmark. A site with more than one drainage area samples each one separately, so it can file more than four results for a pollutant in a year. Open a pollutant to see every lab result behind the averages.

  • Yearly average, over
  • Yearly average, within
  • Single lab result
  • State benchmark

Tested in 2025-26

pH

7 to 72 results

6 to 9

All results for pH

Water that is too acidic or too alkaline harms aquatic life and makes metals more toxic.

6 results as a table
SampledDrainage areaResult
Feb 16, 2026Driveway Entrance7
Jan 22, 2026Driveway Entrance7
Mar 13, 2025Driveway Entrance6.5
Mar 21, 2018Driveway Entrance6.8
Jan 8, 2018Driveway Entrance6.5
Jan 5, 2017Driveway Entrance6.8

Suspended solids

13 mg/L2 results

100 mg/L

All results for suspended solids

Mud and fine particles that cloud water, bury habitat, and carry other pollutants.

15 results as a table
SampledDrainage areaResult
Feb 16, 2026Driveway Entrance4.8 mg/L
Jan 22, 2026Driveway Entrance20 mg/L
Mar 13, 2025Driveway Entrance4.4 mg/L
Jan 22, 2024Driveway Entrance8.3 mg/L
Dec 20, 2023Driveway Entrance37 mg/L
Jan 10, 2023Driveway Entrance8.6 mg/L
Jan 10, 2023Driveway Entrance6.5 mg/L
Dec 12, 2022Driveway Entrance29 mg/L
Dec 12, 2022Driveway Entrance27 mg/L
Nov 8, 2022Driveway Entrance37 mg/L
Dec 14, 2021Driveway Entrance48 mg/L
Nov 20, 2019Driveway Entrance37 mg/L
Mar 21, 2018Driveway Entrance87 mg/L
Jan 8, 2018Driveway Entrance102 mg/L
Jan 5, 2017Driveway Entrance84 mg/L

Oil and grease

12 mg/L2 results

15 mg/L

All results for oil and grease

Coats plants and animals and blocks oxygen from entering the water.

15 results as a table
SampledDrainage areaResult
Feb 16, 2026Driveway Entrance8.2 mg/L
Jan 22, 2026Driveway Entrance15 mg/L
Mar 13, 2025Driveway EntranceNot detected
Jan 22, 2024Driveway Entrance3.5 mg/L
Dec 20, 2023Driveway Entrance3.8 mg/L
Jan 10, 2023Driveway Entrance2.7 mg/L
Jan 10, 2023Driveway Entrance1.6 mg/L
Dec 12, 2022Driveway Entrance5.1 mg/L
Dec 12, 2022Driveway Entrance4.5 mg/L
Nov 8, 2022Driveway Entrance1.4 mg/L
Dec 14, 2021Driveway Entrance4 mg/L
Nov 20, 2019Driveway Entrance2.8 mg/L
Mar 21, 2018Driveway Entrance0.82 mg/L
Jan 8, 2018Driveway Entrance5 mg/L
Jan 5, 2017Driveway Entrance7.8 mg/L

Lead

0.019 mg/L2 results

0.262 mg/L

All results for lead

A nerve poison for people and wildlife that builds up in sediment.

13 results as a table
SampledDrainage areaResult
Feb 16, 2026Driveway Entrance0.019 mg/L
Jan 22, 2026Driveway Entrance0.019 mg/L
Mar 13, 2025Driveway Entrance0.0018 mg/L
Jan 22, 2024Driveway Entrance0.046 mg/L
Dec 20, 2023Driveway Entrance0.012 mg/L
Jan 10, 2023Driveway Entrance0.0037 mg/L
Jan 10, 2023Driveway Entrance0.003 mg/L
Dec 12, 2022Driveway Entrance0.011 mg/L
Dec 12, 2022Driveway Entrance0.007 mg/L
Nov 8, 2022Driveway Entrance0.0097 mg/L
Dec 14, 2021Driveway Entrance0.011 mg/L
Nov 20, 2019Driveway Entrance0.017 mg/L
Mar 21, 2018Driveway Entrance0.028 mg/L

Also tested, with no state benchmark to compare against: 15 results for total organic carbon (TOC) and 3 for electrical conductivity @ 25 deg. C.

Rain and sampling by year

The permit asks each site to sample two storms between July and December and two between January and June. When a site samples fewer, its results may not represent its true runoff.

  • Day with rain
  • Day sampled
2025-26

1 of 9 storms sampledTold the state it sampled every required storm

2024-25

1 of 6 storms sampledTold the state it sampled every required storm

2023-24

2 of 15 storms sampledNo annual report on file

2022-23

3 of 17 storms sampledTold the state it sampled every required storm

2021-22

1 of 10 storms sampledNo annual report on file

2020-21

0 of 7 storms sampledTold the state it sampled every required storm

Rainfall comes from the daily records of NOAA station Los Angeles Downtown (USW00093134), 4 miles from the site. It is the nearest station with a full record since 2015. A storm here means a tenth of an inch or more of rain after two dry days.

Location and details

Where the runoff goes

The facility reports that rain running off it drains to L A River.

The site sits in a watershed with a state cleanup plan for metals and nutrients.

Storm drains carry this runoff to creeks and the ocean without treatment.

The neighborhood

About 331 people live in the neighborhood around this site in Los Angeles. The state scores it above 94% of California neighborhoods for pollution burden and health vulnerability.

Least burdenedMost burdened

Source: CalEnviroScreen 5.0, census tract 6037980016. The score covers the whole neighborhood and does not measure this site's own effect.

Permits and IDs

Industry
Industrial Organic Chemicals, NEC
Operator
Four Star Chemical
Covered by
Industrial stormwater permit
Stormwater permit since
November 1994
Site size
3 acres
State stormwater ID
4 19I011284

The state stormwater record

Report pollution at this site

Send photos or video of what you have seen, such as smoke, runoff, or uncovered materials. We review every report.

Send a report