EarthSpotterEarthSpotter

Asco Metals

13014 Los Nietos Rd, Santa Fe Springs, CA 90670

Asco Metals has held an industrial stormwater permit for the site since January 1993. Its industry is listed as scrap and waste materials. Its runoff was over a state benchmark in 1 of the 2 years it sampled in the last five, most recently in 2025-26 for zinc, aluminum, and iron. Under its stormwater permit it is at Exceedance Response Action Level 1 for zinc, iron, and aluminum, and its runoff drains to San Gabriel River Reach 2 and its tributary/ies, where a state cleanup plan sets stricter limits for lead.

13014 Los Nietos Rd, Santa Fe Springs

Industrial stormwater

During the 2025-2026 rainy season, the site exceeded benchmarks set by the state for zinc, aluminum, and iron.

Its yearly average for zinc was 3.3 times the benchmark. It has exceeded at least one benchmark in 1 of the last 2 years it sampled.

Clean WaterIndustrial stormwater

Over a state benchmark

Clean Water Act. Source: California State Water Resources Control Board, data as of November 23, 2026.

Rain and sampling in 2025-26

The facility sampled 1 of the 10 storms of a tenth of an inch or more near the site in 2025-26.

The permit generally requires samples from four storms a year, with few exceptions. The facility told the state it missed storms because storms did not produce a discharge, storms fell outside operating hours, and the facility was not operating or was understaffed.

What the samples show

The state compares each year's average with its benchmark. A site with more than one drainage area samples each one separately, so it can file more than four results for a pollutant in a year. Open a pollutant to see every lab result behind the averages.

  • Yearly average, over
  • Yearly average, within
  • Single lab result
  • State benchmark

Over the benchmark in 2025-26

Zinc

0.84 mg/L1 result

0.26 mg/L

Exceedance Response Action Level 1

All results for zinc

Toxic to fish and the small animals they eat, even at low concentrations.

2 results as a table
SampledDrainage areaResult
Oct 13, 2025FRONT PARKING LOT0.84 mg/L
Jan 9, 2018FRONT PARKING LOTNot detected

Aluminum

1.5 mg/L1 result

0.75 mg/L

Exceedance Response Action Level 1

All results for aluminum

Toxic to fish and aquatic insects. It builds up on gills.

2 results as a table
SampledDrainage areaResult
Oct 13, 2025FRONT PARKING LOT1.5 mg/L
Jan 9, 2018FRONT PARKING LOTNot detected

Iron

2.2 mg/L1 result

1 mg/L

Exceedance Response Action Level 1

All results for iron

Settles out as rust-colored sludge that smothers creek beds. The state took its iron benchmark from a 2008 EPA benchmark that the EPA has since stopped using.

2 results as a table
SampledDrainage areaResult
Oct 13, 2025FRONT PARKING LOT2.2 mg/L
Jan 9, 2018FRONT PARKING LOTNot detected

Within the benchmark

pH

7.3 to 7.31 result

6 to 9

All results for pH

Water that is too acidic or too alkaline harms aquatic life and makes metals more toxic.

6 results as a table
SampledDrainage areaResult
Oct 13, 2025FRONT PARKING LOT7.3
Dec 14, 2021FRONT PARKING LOT6.8
Jan 29, 2021Front yard6.6
Apr 6, 2020FRONT PARKING LOT6.9
Mar 13, 2020FRONT PARKING LOT6
Dec 4, 2019FRONT PARKING LOT5.7

Suspended solids

55 mg/L1 result

100 mg/L

All results for suspended solids

Mud and fine particles that cloud water, bury habitat, and carry other pollutants.

7 results as a table
SampledDrainage areaResult
Oct 13, 2025FRONT PARKING LOT55 mg/L
Dec 14, 2021FRONT PARKING LOT52 mg/L
Jan 29, 2021Front yardNot detected
Apr 6, 2020FRONT PARKING LOTNot detected
Mar 13, 2020FRONT PARKING LOTNot detected
Dec 4, 2019FRONT PARKING LOTNot detected
Jan 9, 2018FRONT PARKING LOTNot detected

Oil and grease

5 mg/L1 result

15 mg/L

All results for oil and grease

Coats plants and animals and blocks oxygen from entering the water.

6 results as a table
SampledDrainage areaResult
Oct 13, 2025FRONT PARKING LOT5 mg/L
Dec 14, 2021FRONT PARKING LOTNot detected
Jan 29, 2021Front yardNot detected
Apr 6, 2020FRONT PARKING LOTNot detected
Mar 13, 2020FRONT PARKING LOTNot detected
Dec 4, 2019FRONT PARKING LOTNot detected

Lead

0.074 mg/L1 result

0.262 mg/L

All results for lead

A nerve poison for people and wildlife that builds up in sediment.

7 results as a table
SampledDrainage areaResult
Oct 13, 2025FRONT PARKING LOT0.074 mg/L
Dec 14, 2021FRONT PARKING LOTNot detected
Jan 29, 2021Front yardNot detected
Apr 6, 2020FRONT PARKING LOTNot detected
Mar 13, 2020FRONT PARKING LOTNot detected
Dec 4, 2019FRONT PARKING LOTNot detected
Jan 9, 2018FRONT PARKING LOTNot detected

Chemical oxygen demand

Not detected1 result

120 mg/L

All results for chemical oxygen demand

A measure of oxygen-consuming waste. High readings leave less oxygen for aquatic life.

7 results as a table
SampledDrainage areaResult
Oct 13, 2025FRONT PARKING LOTNot detected
Dec 14, 2021FRONT PARKING LOTNot detected
Jan 29, 2021Front yardNot detected
Apr 6, 2020FRONT PARKING LOTNot detected
Mar 13, 2020FRONT PARKING LOTNot detected
Dec 4, 2019FRONT PARKING LOTNot detected
Jan 9, 2018FRONT PARKING LOTNot detected

Stricter limits under the R4 - San Gabriel River Metals and Selenium cleanup plan

This site drains to San Gabriel River Reach 2 and its tributary/ies, which has a cleanup plan. These apply to single results, not yearly averages. Two or more results over in a year count as an exceedance.

PollutantLimitResults over in 2025-26
Lead0.166 mg/L0 of 1Becomes a legal limit on Jul 1, 2020

Rain and sampling by year

The permit asks each site to sample two storms between July and December and two between January and June. When a site samples fewer, its results may not represent its true runoff.

  • Day with rain
  • Day sampled
2025-26

1 of 10 storms sampledTold the state: storms did not produce a discharge; storms fell outside operating hours; the facility was not operating or was understaffed

2024-25

0 of 6 storms sampledTold the state it sampled every required storm

2023-24

0 of 17 storms sampledTold the state it sampled every required storm

2022-23

0 of 16 storms sampledTold the state it did not sample every required storm

2021-22

1 of 10 storms sampledTold the state it did not sample every required storm

2020-21

1 of 7 storms sampledTold the state it sampled every required storm

Rainfall comes from the daily records of NOAA station Whittier 2.9 WNW (US1CALA0010), 2.9 miles from the site. It is the nearest station with a full record since 2015. A storm here means a tenth of an inch or more of rain after two dry days.

Location and details

Where the runoff goes

The facility reports that rain running off it drains to S San Gabriel Water Basin.

The site sits in a watershed with a state cleanup plan for metals and selenium.

Storm drains carry this runoff to creeks and the ocean without treatment.

The neighborhood

About 7,320 people live in the neighborhood around this site in Santa Fe Springs. The state scores it above 97% of California neighborhoods for pollution burden and health vulnerability.

Least burdenedMost burdened

Source: CalEnviroScreen 5.0, census tract 6037504200. The score covers the whole neighborhood and does not measure this site's own effect.

Permits and IDs

Industry
Scrap and Waste Materials
Operator
Asco Metals
Covered by
Industrial stormwater permit
Stormwater permit since
January 1993
Site size
40000 square feet
Paved or roofed
100% of the site
State stormwater ID
4 19I009708

The state stormwater record

Report pollution at this site

Send photos or video of what you have seen, such as smoke, runoff, or uncovered materials. We review every report.

Send a report