Asco Metals has held an industrial stormwater permit for the site since January 1993. Its industry is listed as scrap and waste materials. Its runoff was over a state benchmark in 1 of the 2 years it sampled in the last five, most recently in 2025-26 for zinc, aluminum, and iron. Under its stormwater permit it is at Exceedance Response Action Level 1 for zinc, iron, and aluminum, and its runoff drains to San Gabriel River Reach 2 and its tributary/ies, where a state cleanup plan sets stricter limits for lead.
13014 Los Nietos Rd, Santa Fe Springs
Industrial stormwater
During the 2025-2026 rainy season, the site exceeded benchmarks set by the state for zinc, aluminum, and iron.
Its yearly average for zinc was 3.3 times the benchmark. It has exceeded at least one benchmark in 1 of the last 2 years it sampled.
Clean WaterIndustrial stormwater
Over a state benchmark
Clean Water Act. Source: California State Water Resources Control Board, data as of November 23, 2026.
Rain and sampling in 2025-26
The facility sampled 1 of the 10 storms of a tenth of an inch or more near the site in 2025-26.
The permit generally requires samples from four storms a year, with few exceptions. The facility told the state it missed storms because storms did not produce a discharge, storms fell outside operating hours, and the facility was not operating or was understaffed.
What the samples show
The state compares each year's average with its benchmark. A site with more than one drainage area samples each one separately, so it can file more than four results for a pollutant in a year. Open a pollutant to see every lab result behind the averages.
Yearly average, over
Yearly average, within
Single lab result
State benchmark
Over the benchmark in 2025-26
Pollutant2025-26 averageBenchmarkLast five years
Zinc
0.84 mg/L1 result
0.26 mg/L
Over in 1 of 1 year tested
Exceedance Response Action Level 1
All results for zinc
Toxic to fish and the small animals they eat, even at low concentrations.
2 results as a table
Sampled
Drainage area
Result
Oct 13, 2025
FRONT PARKING LOT
0.84 mg/L
Jan 9, 2018
FRONT PARKING LOT
Not detected
Aluminum
1.5 mg/L1 result
0.75 mg/L
Over in 1 of 1 year tested
Exceedance Response Action Level 1
All results for aluminum
Toxic to fish and aquatic insects. It builds up on gills.
2 results as a table
Sampled
Drainage area
Result
Oct 13, 2025
FRONT PARKING LOT
1.5 mg/L
Jan 9, 2018
FRONT PARKING LOT
Not detected
Iron
2.2 mg/L1 result
1 mg/L
Over in 1 of 1 year tested
Exceedance Response Action Level 1
All results for iron
Settles out as rust-colored sludge that smothers creek beds. The state took its iron benchmark from a 2008 EPA benchmark that the EPA has since stopped using.
2 results as a table
Sampled
Drainage area
Result
Oct 13, 2025
FRONT PARKING LOT
2.2 mg/L
Jan 9, 2018
FRONT PARKING LOT
Not detected
Within the benchmark
Pollutant2025-26 averageBenchmarkLast five years
pH
7.3 to 7.31 result
6 to 9
Over in 0 of 2 years tested
All results for pH
Water that is too acidic or too alkaline harms aquatic life and makes metals more toxic.
6 results as a table
Sampled
Drainage area
Result
Oct 13, 2025
FRONT PARKING LOT
7.3
Dec 14, 2021
FRONT PARKING LOT
6.8
Jan 29, 2021
Front yard
6.6
Apr 6, 2020
FRONT PARKING LOT
6.9
Mar 13, 2020
FRONT PARKING LOT
6
Dec 4, 2019
FRONT PARKING LOT
5.7
Suspended solids
55 mg/L1 result
100 mg/L
Over in 0 of 2 years tested
All results for suspended solids
Mud and fine particles that cloud water, bury habitat, and carry other pollutants.
7 results as a table
Sampled
Drainage area
Result
Oct 13, 2025
FRONT PARKING LOT
55 mg/L
Dec 14, 2021
FRONT PARKING LOT
52 mg/L
Jan 29, 2021
Front yard
Not detected
Apr 6, 2020
FRONT PARKING LOT
Not detected
Mar 13, 2020
FRONT PARKING LOT
Not detected
Dec 4, 2019
FRONT PARKING LOT
Not detected
Jan 9, 2018
FRONT PARKING LOT
Not detected
Oil and grease
5 mg/L1 result
15 mg/L
Over in 0 of 2 years tested
All results for oil and grease
Coats plants and animals and blocks oxygen from entering the water.
6 results as a table
Sampled
Drainage area
Result
Oct 13, 2025
FRONT PARKING LOT
5 mg/L
Dec 14, 2021
FRONT PARKING LOT
Not detected
Jan 29, 2021
Front yard
Not detected
Apr 6, 2020
FRONT PARKING LOT
Not detected
Mar 13, 2020
FRONT PARKING LOT
Not detected
Dec 4, 2019
FRONT PARKING LOT
Not detected
Lead
0.074 mg/L1 result
0.262 mg/L
Over in 0 of 2 years tested
All results for lead
A nerve poison for people and wildlife that builds up in sediment.
7 results as a table
Sampled
Drainage area
Result
Oct 13, 2025
FRONT PARKING LOT
0.074 mg/L
Dec 14, 2021
FRONT PARKING LOT
Not detected
Jan 29, 2021
Front yard
Not detected
Apr 6, 2020
FRONT PARKING LOT
Not detected
Mar 13, 2020
FRONT PARKING LOT
Not detected
Dec 4, 2019
FRONT PARKING LOT
Not detected
Jan 9, 2018
FRONT PARKING LOT
Not detected
Chemical oxygen demand
Not detected1 result
120 mg/L
Over in 0 of 2 years tested
All results for chemical oxygen demand
A measure of oxygen-consuming waste. High readings leave less oxygen for aquatic life.
7 results as a table
Sampled
Drainage area
Result
Oct 13, 2025
FRONT PARKING LOT
Not detected
Dec 14, 2021
FRONT PARKING LOT
Not detected
Jan 29, 2021
Front yard
Not detected
Apr 6, 2020
FRONT PARKING LOT
Not detected
Mar 13, 2020
FRONT PARKING LOT
Not detected
Dec 4, 2019
FRONT PARKING LOT
Not detected
Jan 9, 2018
FRONT PARKING LOT
Not detected
Stricter limits under the R4 - San Gabriel River Metals and Selenium cleanup plan
This site drains to San Gabriel River Reach 2 and its tributary/ies, which has a cleanup plan. These apply to single results, not yearly averages. Two or more results over in a year count as an exceedance.
Pollutant
Limit
Results over in 2025-26
Lead
0.166 mg/L
0 of 1
Becomes a legal limit on Jul 1, 2020
Rain and sampling by year
The permit asks each site to sample two storms between July and December and two between January and June. When a site samples fewer, its results may not represent its true runoff.
Day with rain
Day sampled
2025-26
1 of 10 storms sampledTold the state: storms did not produce a discharge; storms fell outside operating hours; the facility was not operating or was understaffed
2024-25
0 of 6 storms sampledTold the state it sampled every required storm
2023-24
0 of 17 storms sampledTold the state it sampled every required storm
2022-23
0 of 16 storms sampledTold the state it did not sample every required storm
2021-22
1 of 10 storms sampledTold the state it did not sample every required storm
2020-21
1 of 7 storms sampledTold the state it sampled every required storm
JulAugSepOctNovDecJanFebMarAprMayJun
Rainfall comes from the daily records of NOAA station Whittier 2.9 WNW (US1CALA0010), 2.9 miles from the site. It is the nearest station with a full record since 2015. A storm here means a tenth of an inch or more of rain after two dry days.
Location and details
Where the runoff goes
The facility reports that rain running off it drains to S San Gabriel Water Basin.
The site sits in a watershed with a state cleanup plan for metals and selenium.
Storm drains carry this runoff to creeks and the ocean without treatment.
The neighborhood
About 7,320 people live in the neighborhood around this site in Santa Fe Springs. The state scores it above 97% of California neighborhoods for pollution burden and health vulnerability.
Least burdenedMost burdened
Source: CalEnviroScreen 5.0, census tract 6037504200. The score covers the whole neighborhood and does not measure this site's own effect.