Cal Tron Plating Inc has held an industrial stormwater permit for the site since November 1992. Its industry is listed as electroplating, plating, polishing, anodizing, and coloring. The permit requires samples of its runoff, and the last one it filed is from March 2023. Under its stormwater permit it is at Exceedance Response Action Level 1 for 4 pollutants, and the site is in a watershed with a state cleanup plan for metals and selenium.
11919 Rivera Rd, Santa Fe Springs
Industrial stormwater
This site last filed a sample of its runoff in March 2023.
The permit requires testing. It has filed no results for the last three years, so there is no public record of what its runoff contains.
Clean WaterIndustrial stormwater
Missing samples
Clean Water Act. Source: California State Water Resources Control Board, data as of November 23, 2026.
Rain and sampling in 2025-26
The facility sampled none of the 10 storms of a tenth of an inch or more near the site in 2025-26.
The permit generally requires samples from four storms a year, with few exceptions. The facility told the state it missed storms because not enough qualifying storms occurred, storms did not produce a discharge, and storms fell outside operating hours.
What the samples show
The state compares each year's average with its benchmark. A site with more than one drainage area samples each one separately, so it can file more than four results for a pollutant in a year. Open a pollutant to see every lab result behind the averages.
Yearly average, over
Yearly average, within
Single lab result
State benchmark
Not tested in the latest year
Figures are from the last year each was tested.
PollutantAverage when last testedBenchmarkLast five years
Zinc
0.093 mg/L1 result
0.26 mg/L
Over in 1 of 2 years tested
Exceedance Response Action Level 1
All results for zinc
Toxic to fish and the small animals they eat, even at low concentrations.
3 results as a table
Sampled
Drainage area
Result
Mar 1, 2023
S1 Sheet Flow
0.093 mg/L
Mar 28, 2022
mon-1
0.33 mg/L
Mar 22, 2018
mon-1
0.25 mg/L
Iron
0.23 mg/L1 result
1 mg/L
Over in 1 of 2 years tested
Exceedance Response Action Level 1
All results for iron
Settles out as rust-colored sludge that smothers creek beds. The state took its iron benchmark from a 2008 EPA benchmark that the EPA has since stopped using.
3 results as a table
Sampled
Drainage area
Result
Mar 1, 2023
S1 Sheet Flow
0.23 mg/L
Mar 28, 2022
mon-1
1.5 mg/L
Mar 22, 2018
mon-1
0.27 mg/L
Aluminum
0.11 mg/L1 result
0.75 mg/L
Over in 1 of 2 years tested
Exceedance Response Action Level 1
All results for aluminum
Toxic to fish and aquatic insects. It builds up on gills.
3 results as a table
Sampled
Drainage area
Result
Mar 1, 2023
S1 Sheet Flow
0.11 mg/L
Mar 28, 2022
mon-1
1.1 mg/L
Mar 22, 2018
mon-1
0.18 mg/L
Nitrate and nitrite
0.12 mg/L1 result
0.68 mg/L
Over in 0 of 2 years tested
Exceedance Response Action Level 1
All results for nitrate and nitrite
Feeds algae blooms that strip oxygen from creeks and lagoons.
3 results as a table
Sampled
Drainage area
Result
Mar 1, 2023
mon-1
0.12 mg/L
Mar 28, 2022
mon-1
Not detected
Mar 22, 2018
mon-1
0.72 mg/L
pH
7 to 7.22 results, 2 drainage areas
6 to 9
Over in 0 of 2 years tested
All results for pH
Water that is too acidic or too alkaline harms aquatic life and makes metals more toxic.
2022-23 results by drainage area
The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.
Drainage area
Results
Lowest
Highest
mon-1
1
7.2
7.2
S1 Sheet Flow
1
7
7
4 results as a table
Sampled
Drainage area
Result
Mar 1, 2023
S1 Sheet Flow
7
Mar 1, 2023
mon-1
7.2
Mar 28, 2022
mon-1
5.2
Mar 22, 2018
mon-1
7.7
Suspended solids
2.8 mg/L2 results, 2 drainage areas
100 mg/L
Over in 0 of 2 years tested
All results for suspended solids
Mud and fine particles that cloud water, bury habitat, and carry other pollutants.
2022-23 results by drainage area
The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.
Drainage area
Results
Average
Highest
mon-1
1
4.2 mg/L
4.2 mg/L
S1 Sheet Flow
1
1.4 mg/L
1.4 mg/L
4 results as a table
Sampled
Drainage area
Result
Mar 1, 2023
S1 Sheet Flow
1.4 mg/L
Mar 1, 2023
mon-1
4.2 mg/L
Mar 28, 2022
mon-1
28 mg/L
Mar 22, 2018
mon-1
7 mg/L
Oil and grease
3 mg/L2 results, 2 drainage areas
15 mg/L
Over in 0 of 2 years tested
All results for oil and grease
Coats plants and animals and blocks oxygen from entering the water.
2022-23 results by drainage area
The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.
Drainage area
Results
Average
Highest
mon-1
1
0 mg/L
0 mg/L
S1 Sheet Flow
1
6 mg/L
6 mg/L
4 results as a table
Sampled
Drainage area
Result
Mar 1, 2023
S1 Sheet Flow
6 mg/L
Mar 1, 2023
mon-1
Not detected
Mar 28, 2022
mon-1
Not detected
Mar 22, 2018
mon-1
0.8 mg/L
Rain and sampling by year
The permit asks each site to sample two storms between July and December and two between January and June. When a site samples fewer, its results may not represent its true runoff.
Day with rain
Day sampled
2025-26
0 of 10 storms sampledTold the state: not enough qualifying storms occurred; storms did not produce a discharge; storms fell outside operating hours
2024-25
0 of 6 storms sampledTold the state it did not sample every required storm
2023-24
0 of 17 storms sampledTold the state it did not sample every required storm
2022-23
1 of 16 storms sampledTold the state it did not sample every required storm
2021-22
1 of 10 storms sampledTold the state it did not sample every required storm
2020-21
0 of 7 storms sampledTold the state it did not sample every required storm
JulAugSepOctNovDecJanFebMarAprMayJun
Rainfall comes from the daily records of NOAA station Whittier 2.9 WNW (US1CALA0010), 1.5 miles from the site. It is the nearest station with a full record since 2015. A storm here means a tenth of an inch or more of rain after two dry days.
Location and details
Where the runoff goes
The facility reports that rain running off it drains to Storm drains.
The site sits in a watershed with a state cleanup plan for metals and selenium.
Storm drains carry this runoff to creeks and the ocean without treatment.
The neighborhood
About 7,159 people live in the neighborhood around this site in Santa Fe Springs. The state scores it above 86% of California neighborhoods for pollution burden and health vulnerability.
Least burdenedMost burdened
Source: CalEnviroScreen 5.0, census tract 6037502700. The score covers the whole neighborhood and does not measure this site's own effect.
Permits and IDs
Industry
Electroplating, Plating, Polishing, Anodizing, and Coloring