EarthSpotterEarthSpotter

Picknpull San Jose North 40

1065 Commercial St, San Jose, CA 95112

Pick N Pull San Jose Auto Dismantler General Partnership has held an industrial stormwater permit for the site since May 1992. Its industry is listed as motor vehicle parts, used. Its runoff was over a state benchmark in 3 of the 4 years it sampled in the last five, most recently in 2025-26 for chemical oxygen demand and iron. Under its stormwater permit it is at Exceedance Response Action Level 2 for iron and chemical oxygen demand, which means it must file an action plan with the state.

1065 Commercial St, San Jose

Industrial stormwater

During the 2025-2026 rainy season, the site exceeded benchmarks set by the state for chemical oxygen demand and iron.

Its yearly average for chemical oxygen demand was 1.8 times the benchmark. It has exceeded at least one benchmark in 3 of the last 4 years it sampled.

Clean WaterIndustrial stormwater

Over a state benchmark

Clean Water Act. Source: California State Water Resources Control Board, data as of November 23, 2026.

Rain and sampling in 2025-26

The facility sampled 3 of the 12 storms of a tenth of an inch or more near the site in 2025-26.

The permit generally requires samples from four storms a year, with few exceptions. The facility told the state it missed storms because not enough qualifying storms occurred, storms did not produce a discharge, and storms fell outside operating hours. It also gave another reason.

What the samples show

The state compares each year's average with its benchmark. A site with more than one drainage area samples each one separately, so it can file more than four results for a pollutant in a year. Open a pollutant to see every lab result behind the averages.

  • Yearly average, over
  • Yearly average, within
  • Single lab result
  • State benchmark

Over the benchmark in 2025-26

Chemical oxygen demand

211 mg/L3 results

120 mg/L

Exceedance Response Action Level 2

All results for chemical oxygen demand

A measure of oxygen-consuming waste. High readings leave less oxygen for aquatic life.

21 results as a table
SampledDrainage areaResult
Apr 21, 2026DP-1142 mg/L
Feb 16, 2026DP-1338 mg/L
Nov 17, 2025DP-1154 mg/L
Jan 22, 2024DP-1190 mg/L
Jan 3, 2024DP-1160 mg/L
Dec 21, 2023DP-114 mg/L
Jan 10, 2023DP-126 mg/L
Jan 4, 2023DP-122 mg/L
Dec 27, 2022DP-1120 mg/L
Dec 12, 2022DP-180 mg/L
Nov 8, 2022DP-122 mg/L
Dec 23, 2021DP-1690 mg/L
Dec 14, 2021DP-1730 mg/L
Oct 25, 2021DP-193 mg/L
Mar 23, 2020DP-1350 mg/L
Dec 8, 2019DP-1400 mg/L
Mar 2, 2019DP-168 mg/L
Jan 7, 2019DP-1510 mg/L
Mar 13, 2018DP-1700 mg/L
Jan 9, 2018DP-1340 mg/L
Jan 19, 2016DP-1450 mg/L

Iron

1.6 mg/L3 results

1 mg/L

Exceedance Response Action Level 2

All results for iron

Settles out as rust-colored sludge that smothers creek beds. The state took its iron benchmark from a 2008 EPA benchmark that the EPA has since stopped using.

21 results as a table
SampledDrainage areaResult
Apr 21, 2026DP-13 mg/L
Feb 16, 2026DP-11.3 mg/L
Nov 17, 2025DP-10.52 mg/L
Jan 22, 2024DP-11.3 mg/L
Jan 3, 2024DP-11.6 mg/L
Dec 21, 2023DP-11.5 mg/L
Jan 10, 2023DP-11.3 mg/L
Jan 4, 2023DP-10.14 mg/L
Dec 27, 2022DP-10.088 mg/L
Dec 12, 2022DP-12.3 mg/L
Nov 8, 2022DP-10.23 mg/L
Dec 23, 2021DP-14.6 mg/L
Dec 14, 2021DP-118 mg/L
Oct 25, 2021DP-11.7 mg/L
Mar 23, 2020DP-17.1 mg/L
Dec 8, 2019DP-111 mg/L
Mar 2, 2019DP-11.6 mg/L
Jan 7, 2019DP-16 mg/L
Mar 13, 2018DP-116 mg/L
Jan 9, 2018DP-17.8 mg/L
Jan 19, 2016DP-115 mg/L

Within the benchmark

Aluminum

0.6 mg/L3 results

0.75 mg/L

All results for aluminum

Toxic to fish and aquatic insects. It builds up on gills.

21 results as a table
SampledDrainage areaResult
Apr 21, 2026DP-11 mg/L
Feb 16, 2026DP-10.65 mg/L
Nov 17, 2025DP-10.13 mg/L
Jan 22, 2024DP-10.041 mg/L
Jan 3, 2024DP-1Not detected
Dec 21, 2023DP-1Not detected
Jan 10, 2023DP-11 mg/L
Jan 4, 2023DP-1Not detected
Dec 27, 2022DP-10.18 mg/L
Dec 12, 2022DP-11.9 mg/L
Nov 8, 2022DP-10.22 mg/L
Dec 23, 2021DP-12.9 mg/L
Dec 14, 2021DP-111 mg/L
Oct 25, 2021DP-11.1 mg/L
Mar 23, 2020DP-13.7 mg/L
Dec 8, 2019DP-15.9 mg/L
Mar 2, 2019DP-10.83 mg/L
Jan 7, 2019DP-11.5 mg/L
Mar 13, 2018DP-17.6 mg/L
Jan 9, 2018DP-14.5 mg/L
Jan 19, 2016DP-17.1 mg/L

Copper

0.0056 mg/L3 results

0.0332 mg/L

All results for copper

Toxic to fish at very low concentrations and damages their sense of smell.

20 results as a table
SampledDrainage areaResult
Apr 21, 2026DP-10.0065 mg/L
Feb 16, 2026DP-10.0034 mg/L
Nov 17, 2025DP-10.0067 mg/L
Jan 22, 2024DP-10.0028 mg/L
Jan 3, 2024DP-1Not detected
Dec 21, 2023DP-1Not detected
Jan 10, 2023DP-10.0056 mg/L
Jan 4, 2023DP-1Not detected
Dec 27, 2022DP-1Not detected
Dec 12, 2022DP-10.013 mg/L
Nov 8, 2022DP-10.0027 mg/L
Dec 23, 2021DP-10.031 mg/L
Dec 14, 2021DP-10.11 mg/L
Oct 25, 2021DP-10.021 mg/L
Dec 8, 2019DP-10.056 mg/L
Mar 2, 2019DP-10.0076 mg/L
Jan 7, 2019DP-10.035 mg/L
Mar 13, 2018DP-10.055 mg/L
Jan 9, 2018DP-10.041 mg/L
Jan 19, 2016DP-10.056 mg/L

Suspended solids

12 mg/L3 results

100 mg/L

All results for suspended solids

Mud and fine particles that cloud water, bury habitat, and carry other pollutants.

21 results as a table
SampledDrainage areaResult
Apr 21, 2026DP-121 mg/L
Feb 16, 2026DP-110 mg/L
Nov 17, 2025DP-14.8 mg/L
Jan 22, 2024DP-14.4 mg/L
Jan 3, 2024DP-11 mg/L
Dec 21, 2023DP-12.8 mg/L
Jan 10, 2023DP-135 mg/L
Jan 4, 2023DP-1Not detected
Dec 27, 2022DP-13 mg/L
Dec 12, 2022DP-138 mg/L
Nov 8, 2022DP-13 mg/L
Dec 23, 2021DP-156 mg/L
Dec 14, 2021DP-1236 mg/L
Oct 25, 2021DP-139 mg/L
Mar 23, 2020DP-173 mg/L
Dec 8, 2019DP-180 mg/L
Mar 2, 2019DP-124 mg/L
Jan 7, 2019DP-182 mg/L
Mar 13, 2018DP-1170 mg/L
Jan 9, 2018DP-192 mg/L
Jan 19, 2016DP-1140 mg/L

pH

6.2 to 73 results

6 to 9

All results for pH

Water that is too acidic or too alkaline harms aquatic life and makes metals more toxic.

21 results as a table
SampledDrainage areaResult
Apr 21, 2026DP-16.2
Feb 16, 2026DP-17
Nov 17, 2025DP-16.9
Jan 22, 2024DP-16.5
Jan 3, 2024DP-16.5
Dec 21, 2023DP-16.5
Jan 10, 2023DP-16.5
Jan 4, 2023DP-16.3
Dec 27, 2022DP-16.5
Dec 12, 2022DP-16.3
Nov 8, 2022DP-17
Dec 23, 2021DP-16.5
Dec 14, 2021DP-16
Oct 25, 2021DP-16.5
Mar 23, 2020DP-17.5
Dec 8, 2019DP-16.5
Mar 2, 2019DP-17
Jan 7, 2019DP-17
Mar 13, 2018DP-17
Jan 9, 2018DP-18
Jan 19, 2016DP-15.9

Oil and grease

Not detected3 results

15 mg/L

All results for oil and grease

Coats plants and animals and blocks oxygen from entering the water.

21 results as a table
SampledDrainage areaResult
Apr 21, 2026DP-1Not detected
Feb 16, 2026DP-1Not detected
Nov 17, 2025DP-1Not detected
Jan 22, 2024DP-1Not detected
Jan 3, 2024DP-1Not detected
Dec 21, 2023DP-1Not detected
Jan 10, 2023DP-1Not detected
Jan 4, 2023DP-1Not detected
Dec 27, 2022DP-1Not detected
Dec 12, 2022DP-1Not detected
Nov 8, 2022DP-1Not detected
Dec 23, 2021DP-1Not detected
Dec 14, 2021DP-1Not detected
Oct 25, 2021DP-1Not detected
Mar 23, 2020DP-12.6 mg/L
Dec 8, 2019DP-12.3 mg/L
Mar 2, 2019DP-12.8 mg/L
Jan 7, 2019DP-16.6 mg/L
Mar 13, 2018DP-111 mg/L
Jan 9, 2018DP-17.3 mg/L
Jan 19, 2016DP-110 mg/L

Zinc

0.024 mg/L3 results

0.26 mg/L

All results for zinc

Toxic to fish and the small animals they eat, even at low concentrations.

21 results as a table
SampledDrainage areaResult
Apr 21, 2026DP-10.041 mg/L
Feb 16, 2026DP-1Not detected
Nov 17, 2025DP-10.03 mg/L
Jan 22, 2024DP-1Not detected
Jan 3, 2024DP-1Not detected
Dec 21, 2023DP-1Not detected
Jan 10, 2023DP-10.033 mg/L
Jan 4, 2023DP-1Not detected
Dec 27, 2022DP-1Not detected
Dec 12, 2022DP-10.07 mg/L
Nov 8, 2022DP-1Not detected
Dec 23, 2021DP-10.15 mg/L
Dec 14, 2021DP-10.56 mg/L
Oct 25, 2021DP-10.058 mg/L
Mar 23, 2020DP-10.15 mg/L
Dec 8, 2019DP-10.22 mg/L
Mar 2, 2019DP-10.046 mg/L
Jan 7, 2019DP-10.17 mg/L
Mar 13, 2018DP-10.25 mg/L
Jan 9, 2018DP-10.19 mg/L
Jan 19, 2016DP-10.25 mg/L

Lead

0.0055 mg/L3 results

0.262 mg/L

All results for lead

A nerve poison for people and wildlife that builds up in sediment.

21 results as a table
SampledDrainage areaResult
Apr 21, 2026DP-10.0093 mg/L
Feb 16, 2026DP-10.0024 mg/L
Nov 17, 2025DP-10.0049 mg/L
Jan 22, 2024DP-10.00065 mg/L
Jan 3, 2024DP-1Not detected
Dec 21, 2023DP-1Not detected
Jan 10, 2023DP-10.011 mg/L
Jan 4, 2023DP-1Not detected
Dec 27, 2022DP-10.00085 mg/L
Dec 12, 2022DP-10.016 mg/L
Nov 8, 2022DP-10.0021 mg/L
Dec 23, 2021DP-10.031 mg/L
Dec 14, 2021DP-10.13 mg/L
Oct 25, 2021DP-10.0068 mg/L
Mar 23, 2020DP-10.0035 mg/L
Dec 8, 2019DP-10.061 mg/L
Mar 2, 2019DP-10.0062 mg/L
Jan 7, 2019DP-10.044 mg/L
Mar 13, 2018DP-10.061 mg/L
Jan 9, 2018DP-10.042 mg/L
Jan 19, 2016DP-10.072 mg/L

Mercury

Not detected3 results

0.0014 mg/L

All results for mercury

6 results as a table
SampledDrainage areaResult
Apr 21, 2026DP-1Not detected
Feb 16, 2026DP-1Not detected
Nov 17, 2025DP-1Not detected
Jan 22, 2024DP-1Not detected
Jan 3, 2024DP-1Not detected
Dec 21, 2023DP-1Not detected

Tested once or twice and within the benchmark: cadmium.

Also tested, with no state benchmark to compare against: 1 result for dissolved cadmium, 1 for dissolved copper, 1 for electrical conductivity @ 25 deg. C, 1 for dissolved lead, 1 for total dissolved solids (TDS), and 1 for dissolved zinc.

Rain and sampling by year

The permit asks each site to sample two storms between July and December and two between January and June. When a site samples fewer, its results may not represent its true runoff.

  • Day with rain
  • Day sampled
2025-26

3 of 12 storms sampledTold the state: not enough qualifying storms occurred; storms did not produce a discharge; storms fell outside operating hours; another reason

2024-25

0 of 14 storms sampledTold the state it did not sample every required storm

2023-24

3 of 19 storms sampledTold the state it did not sample every required storm

2022-23

5 of 18 storms sampledTold the state it sampled every required storm

2021-22

3 of 6 storms sampledTold the state it did not sample every required storm

2020-21

0 of 7 storms sampledTold the state it did not sample every required storm

Rainfall comes from the daily records of NOAA station San Jose (USW00023293), 2.2 miles from the site. It is the nearest station with a full record since 2015. A storm here means a tenth of an inch or more of rain after two dry days.

Location and details

Where the runoff goes

The facility reports that rain running off it drains to Coyote Creek.

Storm drains carry this runoff to creeks and the ocean without treatment.

The neighborhood

About 7,989 people live in the neighborhood around this site in San Jose. The state scores it above 75% of California neighborhoods for pollution burden and health vulnerability.

Least burdenedMost burdened

Source: CalEnviroScreen 5.0, census tract 6085504318. The score covers the whole neighborhood and does not measure this site's own effect.

Same operator

Pick N Pull San Jose Auto Dismantler General Partnership holds 1 other stormwater permit:

Permits and IDs

Industry
Motor Vehicle Parts, Used
Operator
Pick N Pull San Jose Auto Dismantler General Partnership
Covered by
Industrial stormwater permit
Stormwater permit since
May 1992
Site size
13 acres
Paved or roofed
29% of the site
State stormwater ID
2 43I006737

The state stormwater record

Report pollution at this site

Send photos or video of what you have seen, such as smoke, runoff, or uncovered materials. We review every report.

Send a report