EarthSpotterEarthSpotter

Cain Vineyard and Winery

3800 Langtry Rd, Saint Helena, CA 94574

Cain Vineyard & Winery has held an industrial stormwater permit for the site since July 1998. Its industry is listed as wines, brandy, and brandy spirits. The permit requires samples of its runoff, and the last one it filed is from December 2019. The site is in a watershed with a state cleanup plan for sediment.

3800 Langtry Rd, Saint Helena

Industrial stormwater

This site last filed a sample of its runoff in December 2019.

The permit requires testing. It has filed no results for the last three years, so there is no public record of what its runoff contains.

Clean WaterIndustrial stormwater

Missing samples

Clean Water Act. Source: California State Water Resources Control Board, data as of November 23, 2026.

Rain and sampling in 2025-26

The facility sampled none of the 17 storms of a tenth of an inch or more near the site in 2025-26.

The permit generally requires samples from four storms a year, with few exceptions. The facility told the state it missed storms for another reason.

What the samples show

The state compares each year's average with its benchmark. A site with more than one drainage area samples each one separately, so it can file more than four results for a pollutant in a year. Open a pollutant to see every lab result behind the averages.

  • Yearly average, over
  • Yearly average, within
  • Single lab result
  • State benchmark

Not tested in the latest year

Figures are from the last year each was tested.

pH

7 to 72 results, 2 drainage areas

6 to 9

All results for pH

Water that is too acidic or too alkaline harms aquatic life and makes metals more toxic.

2019-20 results by drainage area

The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.

Drainage areaResultsLowestHighest
Hillside Drain - Crush Pad177
Hillside Drain - Winery177
12 results as a table
SampledDrainage areaResult
Dec 4, 2019Hillside Drain - Winery7
Dec 4, 2019Hillside Drain - Crush Pad7
May 15, 2019Hillside Drain - Winery7
May 15, 2019Hillside Drain - Crush Pad7
Dec 16, 2018Hillside Drain - Winery7
Dec 16, 2018Hillside Drain - Crush Pad8
Nov 23, 2018Hillside Drain - Winery8
Nov 23, 2018Hillside Drain - Crush Pad8
Feb 17, 2017Hillside Drain - Winery8
Feb 17, 2017Hillside Drain - Crush Pad8
Oct 14, 2016Hillside Drain - Winery8
Oct 14, 2016Hillside Drain - Crush Pad8

Suspended solids

6.5 mg/L2 results, 2 drainage areas

100 mg/L

All results for suspended solids

Mud and fine particles that cloud water, bury habitat, and carry other pollutants.

2019-20 results by drainage area

The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.

Drainage areaResultsAverageHighest
Hillside Drain - Crush Pad19 mg/L9 mg/L
Hillside Drain - Winery14 mg/L4 mg/L
12 results as a table
SampledDrainage areaResult
Dec 4, 2019Hillside Drain - Winery4 mg/L
Dec 4, 2019Hillside Drain - Crush Pad9 mg/L
May 15, 2019Hillside Drain - Winery20 mg/L
May 15, 2019Hillside Drain - Crush Pad20 mg/L
Dec 16, 2018Hillside Drain - WineryNot detected
Dec 16, 2018Hillside Drain - Crush Pad13 mg/L
Nov 23, 2018Hillside Drain - Winery3 mg/L
Nov 23, 2018Hillside Drain - Crush Pad5 mg/L
Feb 17, 2017Hillside Drain - Winery4 mg/L
Feb 17, 2017Hillside Drain - Crush Pad6 mg/L
Oct 14, 2016Hillside Drain - Winery18 mg/L
Oct 14, 2016Hillside Drain - Crush Pad27 mg/L

Oil and grease

Not detected2 results, 2 drainage areas

15 mg/L

All results for oil and grease

Coats plants and animals and blocks oxygen from entering the water.

2019-20 results by drainage area

The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.

Drainage areaResultsAverageHighest
Hillside Drain - Crush Pad10 mg/L0 mg/L
Hillside Drain - Winery10 mg/L0 mg/L
10 results as a table
SampledDrainage areaResult
Dec 4, 2019Hillside Drain - WineryNot detected
Dec 4, 2019Hillside Drain - Crush PadNot detected
May 15, 2019Hillside Drain - WineryNot detected
May 15, 2019Hillside Drain - Crush PadNot detected
Dec 16, 2018Hillside Drain - WineryNot detected
Dec 16, 2018Hillside Drain - Crush PadNot detected
Nov 23, 2018Hillside Drain - Crush PadNot detected
Feb 17, 2017Hillside Drain - Crush PadNot detected
Oct 14, 2016Hillside Drain - WineryNot detected
Oct 14, 2016Hillside Drain - Crush PadNot detected

Biochemical oxygen demand

Not detected2 results, 2 drainage areas

30 mg/L

All results for biochemical oxygen demand

2019-20 results by drainage area

The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.

Drainage areaResultsAverageHighest
Hillside Drain - Crush Pad10 mg/L0 mg/L
Hillside Drain - Winery10 mg/L0 mg/L
12 results as a table
SampledDrainage areaResult
Dec 4, 2019Hillside Drain - WineryNot detected
Dec 4, 2019Hillside Drain - Crush PadNot detected
May 15, 2019Hillside Drain - Winery27 mg/L
May 15, 2019Hillside Drain - Crush Pad18 mg/L
Dec 16, 2018Hillside Drain - WineryNot detected
Dec 16, 2018Hillside Drain - Crush PadNot detected
Nov 23, 2018Hillside Drain - WineryNot detected
Nov 23, 2018Hillside Drain - Crush Pad7 mg/L
Feb 17, 2017Hillside Drain - Winery21 mg/L
Feb 17, 2017Hillside Drain - Crush PadNot detected
Oct 14, 2016Hillside Drain - Winery6 mg/L
Oct 14, 2016Hillside Drain - Crush Pad8 mg/L

Also tested, with no state benchmark to compare against: 12 results for electrical conductivity @ 25 deg. C.

Rain and sampling by year

The permit asks each site to sample two storms between July and December and two between January and June. When a site samples fewer, its results may not represent its true runoff.

  • Day with rain
  • Day sampled
2025-26

0 of 17 storms sampledTold the state: another reason

2024-25

0 of 16 storms sampledNo annual report on file

2023-24

0 of 22 storms sampledNo annual report on file

2022-23

0 of 13 storms sampledNo annual report on file

2021-22

0 of 17 storms sampledTold the state it did not sample every required storm

2020-21

0 of 17 storms sampledTold the state it did not sample every required storm

Rainfall comes from the daily records of NOAA station Angwin Pacific Union College (USC00040212), 7.5 miles from the site. It is the nearest station with a full record since 2015. A storm here means a tenth of an inch or more of rain after two dry days.

Location and details

Where the runoff goes

The facility reports that rain running off it drains to Napa River.

The site sits in a watershed with a state cleanup plan for sediment.

Storm drains carry this runoff to creeks and the ocean without treatment.

The neighborhood

About 2,532 people live in the neighborhood around this site in Santa Rosa. The state scores it above 7% of California neighborhoods for pollution burden and health vulnerability.

Least burdenedMost burdened

Source: CalEnviroScreen 5.0, census tract 6097151601. The score covers the whole neighborhood and does not measure this site's own effect.

Permits and IDs

Industry
Wines, Brandy, and Brandy Spirits
Operator
Cain Vineyard & Winery
Covered by
Industrial stormwater permit
Stormwater permit since
July 1998
Site size
492 acres
Paved or roofed
60% of the site
State stormwater ID
2 28I014293

The state stormwater record

Other sites nearby

Report pollution at this site

Send photos or video of what you have seen, such as smoke, runoff, or uncovered materials. We review every report.

Send a report