Electro Plating Specialties has held an industrial stormwater permit for the site since August 2015. Its industry is listed as electroplating, plating, polishing, anodizing, and coloring. The permit requires samples of its runoff, and the last one it filed is from March 2017. Under its stormwater permit it is at Exceedance Response Action Level 1 for pH and zinc, which means a qualified professional must review its pollution controls.

2436 american ave, Hayward

Industrial stormwater

This site last filed a sample of its runoff in March 2017.

The permit requires testing. It has filed no results for the last three years, so there is no public record of what its runoff contains.

Clean WaterIndustrial stormwater

Missing samples

Clean Water Act. Source: California State Water Resources Control Board, data as of November 23, 2026.

Rain and sampling in 2025-26

The facility sampled none of the 15 storms of a tenth of an inch or more near the site in 2025-26.

The permit generally requires samples from four storms a year, with few exceptions. The facility told the state it missed storms because storms did not produce a discharge, storms fell outside operating hours, no trained staff were available, and the facility was not operating or was understaffed. It also gave another reason.

What the samples show

The state compares each year's average with its benchmark. A site with more than one drainage area samples each one separately, so it can file more than four results for a pollutant in a year. Open a pollutant to see every lab result behind the averages.

  • Yearly average, over
  • Yearly average, within
  • Single lab result
  • State benchmark

Not tested in the latest year

Figures are from the last year each was tested.

pH

5 to 6.814 results, 2 drainage areas

6 to 9

Exceedance Response Action Level 1

All results for pH

Water that is too acidic or too alkaline harms aquatic life and makes metals more toxic.

2016-17 results by drainage area

The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.

Drainage areaResultsLowestHighest
S-01 Storm Drain S. Side256.8
S-04 Street Gutter N.256.5
4 results as a table
SampledDrainage areaResult
Mar 24, 2017S-04 Street Gutter N.5
Mar 24, 2017S-01 Storm Drain S. Side5
Dec 15, 2016S-04 Street Gutter N.6.5
Dec 15, 2016S-01 Storm Drain S. Side6.8

Zinc

0.27 mg/L4 results, 2 drainage areas

0.26 mg/L

Exceedance Response Action Level 1

All results for zinc

Toxic to fish and the small animals they eat, even at low concentrations.

2016-17 results by drainage area

The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.

Drainage areaResultsAverageHighest
S-01 Storm Drain S. Side20.3 mg/L0.34 mg/L
S-04 Street Gutter N.20.24 mg/L0.27 mg/L
4 results as a table
SampledDrainage areaResult
Mar 24, 2017S-04 Street Gutter N.0.22 mg/L
Mar 24, 2017S-01 Storm Drain S. Side0.25 mg/L
Dec 15, 2016S-04 Street Gutter N.0.27 mg/L
Dec 15, 2016S-01 Storm Drain S. Side0.34 mg/L

Suspended solids

5.6 mg/L4 results, 2 drainage areas

100 mg/L

All results for suspended solids

Mud and fine particles that cloud water, bury habitat, and carry other pollutants.

2016-17 results by drainage area

The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.

Drainage areaResultsAverageHighest
S-01 Storm Drain S. Side28.3 mg/L13 mg/L
S-04 Street Gutter N.22.9 mg/L4.4 mg/L
4 results as a table
SampledDrainage areaResult
Mar 24, 2017S-04 Street Gutter N.1.3 mg/L
Mar 24, 2017S-01 Storm Drain S. Side3.6 mg/L
Dec 15, 2016S-04 Street Gutter N.4.4 mg/L
Dec 15, 2016S-01 Storm Drain S. Side13 mg/L

Oil and grease

0.88 mg/L4 results, 2 drainage areas

15 mg/L

All results for oil and grease

Coats plants and animals and blocks oxygen from entering the water.

2016-17 results by drainage area

The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.

Drainage areaResultsAverageHighest
S-01 Storm Drain S. Side21.8 mg/L3.5 mg/L
S-04 Street Gutter N.20 mg/L0 mg/L
4 results as a table
SampledDrainage areaResult
Mar 24, 2017S-04 Street Gutter N.Not detected
Mar 24, 2017S-01 Storm Drain S. SideNot detected
Dec 15, 2016S-04 Street Gutter N.Not detected
Dec 15, 2016S-01 Storm Drain S. Side3.5 mg/L

Iron

0.31 mg/L4 results, 2 drainage areas

1 mg/L

All results for iron

Settles out as rust-colored sludge that smothers creek beds. The state took its iron benchmark from a 2008 EPA benchmark that the EPA has since stopped using.

2016-17 results by drainage area

The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.

Drainage areaResultsAverageHighest
S-01 Storm Drain S. Side20.52 mg/L0.87 mg/L
S-04 Street Gutter N.20.097 mg/L0.13 mg/L
4 results as a table
SampledDrainage areaResult
Mar 24, 2017S-04 Street Gutter N.0.063 mg/L
Mar 24, 2017S-01 Storm Drain S. Side0.16 mg/L
Dec 15, 2016S-04 Street Gutter N.0.13 mg/L
Dec 15, 2016S-01 Storm Drain S. Side0.87 mg/L

Aluminum

0.33 mg/L4 results, 2 drainage areas

0.75 mg/L

All results for aluminum

Toxic to fish and aquatic insects. It builds up on gills.

2016-17 results by drainage area

The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.

Drainage areaResultsAverageHighest
S-01 Storm Drain S. Side20.53 mg/L0.95 mg/L
S-04 Street Gutter N.20.13 mg/L0.2 mg/L
4 results as a table
SampledDrainage areaResult
Mar 24, 2017S-04 Street Gutter N.0.062 mg/L
Mar 24, 2017S-01 Storm Drain S. Side0.1 mg/L
Dec 15, 2016S-04 Street Gutter N.0.2 mg/L
Dec 15, 2016S-01 Storm Drain S. Side0.95 mg/L

Nitrate and nitrite

0.44 mg/L4 results, 2 drainage areas

0.68 mg/L

All results for nitrate and nitrite

Feeds algae blooms that strip oxygen from creeks and lagoons.

2016-17 results by drainage area

The site samples each drainage area separately, so one storm can produce several results. The state compares the average of all of them with the benchmark.

Drainage areaResultsAverageHighest
S-01 Storm Drain S. Side20.85 mg/L1.3 mg/L
S-04 Street Gutter N.20.031 mg/L0.062 mg/L
4 results as a table
SampledDrainage areaResult
Mar 24, 2017S-04 Street Gutter N.0.062 mg/L
Mar 24, 2017S-01 Storm Drain S. Side0.41 mg/L
Dec 15, 2016S-04 Street Gutter N.Not detected
Dec 15, 2016S-01 Storm Drain S. Side1.3 mg/L

Rain and sampling by year

The permit asks each site to sample two storms between July and December and two between January and June. When a site samples fewer, its results may not represent its true runoff.

  • Day with rain
  • Day sampled
2025-26

0 of 15 storms sampledTold the state: storms did not produce a discharge; storms fell outside operating hours; no trained staff were available; the facility was not operating or was understaffed; another reason

2024-25

0 of 13 storms sampledTold the state it did not sample every required storm

2023-24

0 of 21 storms sampledTold the state it did not sample every required storm

2022-23

0 of 14 storms sampledTold the state it did not sample every required storm

2021-22

0 of 10 storms sampledTold the state it did not sample every required storm

2020-21

0 of 13 storms sampledTold the state it did not sample every required storm

Rainfall comes from the daily records of NOAA station Hayward Air Terminal (USW00093228), 0.9 miles from the site. It is the nearest station with a full record since 2015. A storm here means a tenth of an inch or more of rain after two dry days.

Location and details

Where the runoff goes

The facility reports that rain running off it drains to San Francisco Bay.

Storm drains carry this runoff to creeks and the ocean without treatment.

The neighborhood

About 7,371 people live in the neighborhood around this site in Hayward. The state scores it above 73% of California neighborhoods for pollution burden and health vulnerability.

Least burdenedMost burdened

Source: CalEnviroScreen 5.0, census tract 6001437101. The score covers the whole neighborhood and does not measure this site's own effect.

Permits and IDs

Industry
Electroplating, Plating, Polishing, Anodizing, and Coloring
Operator
Electro Plating Specialties
Covered by
Industrial stormwater permit
Stormwater permit since
August 2015
Site size
22700 square feet
Paved or roofed
98% of the site
State stormwater ID
2 01I026063

The state stormwater record

Report pollution at this site

Send photos or video of what you have seen, such as smoke, runoff, or uncovered materials. We review every report.

Send a report